<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Präklinische Bildgebung | RJL Micro &amp; Analytic</title>
	<atom:link href="https://www.rjl-microanalytic.de/en/schlagwort/praeklinische-bildgebung/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.rjl-microanalytic.de/en</link>
	<description>Analysis service &amp; instrument from a single source</description>
	<lastbuilddate>Mon, 05 Jun 2023 15:49:53 +0000</lastbuilddate>
	<language>en-US</language>
	<sy:updateperiod>
	hourly	</sy:updateperiod>
	<sy:updatefrequency>
	1	</sy:updatefrequency>
	

<image>
	<url>https://www.rjl-microanalytic.de/wp-content/uploads/cropped-RJLMA-favicon-32x32.png</url>
	<title>Präklinische Bildgebung | RJL Micro &amp; Analytic</title>
	<link>https://www.rjl-microanalytic.de/en</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>High Aspect Ratio Tomography für Proben mit hohem Aspektverhältnis</title>
		<link>https://www.rjl-microanalytic.de/en/high-aspect-ratio-tomography/</link>
		
		<dc:creator><![CDATA[Markus J. Heneka]]></dc:creator>
		<pubdate>Mon, 02 Dec 2019 20:00:00 +0000</pubdate>
				<category><![CDATA[Innovative Analytik]]></category>
		<category><![CDATA[Röntgenmikroskopie]]></category>
		<category><![CDATA[Bruker microCT]]></category>
		<category><![CDATA[Micro-CT]]></category>
		<category><![CDATA[Mikrotomographie]]></category>
		<category><![CDATA[Präklinische Bildgebung]]></category>
		<category><![CDATA[Röntgenbildgebung]]></category>
		<category><![CDATA[Röntgentomographie]]></category>
		<category><![CDATA[SkyScan]]></category>
		<guid ispermalink="false">https://new.rjl-microanalytic.de/?p=1415</guid>

					<description><![CDATA[<p>For the latest generation of SkyScan micro-CT devices, Bruker has developed a special scan mode for samples with a high aspect ratio. Objects of this type are characterized by a high ratio of length to width and repeatedly pose challenges for users of microtomography.</p>
<p>The post <a href="https://www.rjl-microanalytic.de/en/high-aspect-ratio-tomography/">High Aspect Ratio Tomography for Samples with a High Aspect Ratio</a> first appeared on <a href="https://www.rjl-microanalytic.de/en">RJL Micro &amp; Analytic</a>.</p>]]></description>
		
		
		
			</item>
		<item>
		<title>SkyScan 1273 – das neue Mikro-CT-Tischgerät für extragroße Proben</title>
		<link>https://www.rjl-microanalytic.de/en/skyscan-1273-das-neue-mikro-ct-tischgerat-fur-extragrosse-proben/</link>
		
		<dc:creator><![CDATA[Markus J. Heneka]]></dc:creator>
		<pubdate>Fri, 01 Feb 2019 20:00:00 +0000</pubdate>
				<category><![CDATA[Innovative Analytik]]></category>
		<category><![CDATA[Röntgenmikroskopie]]></category>
		<category><![CDATA[Bruker microCT]]></category>
		<category><![CDATA[Micro-CT]]></category>
		<category><![CDATA[Mikrotomographie]]></category>
		<category><![CDATA[Präklinische Bildgebung]]></category>
		<category><![CDATA[Röntgenbildgebung]]></category>
		<category><![CDATA[Röntgentomographie]]></category>
		<category><![CDATA[SkyScan]]></category>
		<guid ispermalink="false">https://new.rjl-microanalytic.de/?p=1405</guid>

					<description><![CDATA[<p>With the new SkyScan 1273, Bruker presents a high-resolution X-Ray 3D microscope for large samples in table top format. XXL objects up to 50 cm x 30 cm can be accommodated in the measuring chamber, the largest field of view is 25 cm x 25 cm.</p>
<p>The post <a href="https://www.rjl-microanalytic.de/en/skyscan-1273-das-neue-mikro-ct-tischgerat-fur-extragrosse-proben/">SkyScan 1273 - the New Micro-CT Tabletop Unit for Extra-Large Samples</a> first appeared on <a href="https://www.rjl-microanalytic.de/en">RJL Micro &amp; Analytic</a>.</p>]]></description>
		
		
		
			</item>
		<item>
		<title>Neues SkyScan Nano-CT ermöglicht Scans im Inneren von Objekten</title>
		<link>https://www.rjl-microanalytic.de/en/neues-nanotomographie-system-skyscan-2214/</link>
		
		<dc:creator><![CDATA[Markus J. Heneka]]></dc:creator>
		<pubdate>Wed, 13 Jun 2018 20:00:00 +0000</pubdate>
				<category><![CDATA[Innovative Analytik]]></category>
		<category><![CDATA[Röntgenmikroskopie]]></category>
		<category><![CDATA[Bruker microCT]]></category>
		<category><![CDATA[Micro-CT]]></category>
		<category><![CDATA[Mikrotomographie]]></category>
		<category><![CDATA[Präklinische Bildgebung]]></category>
		<category><![CDATA[Röntgenbildgebung]]></category>
		<category><![CDATA[Röntgentomographie]]></category>
		<category><![CDATA[SkyScan]]></category>
		<guid ispermalink="false">https://new.rjl-microanalytic.de/?p=1384</guid>

					<description><![CDATA[<p>The new nano-CT from the SkyScan family impresses with its excellent optical resolution of less than 0.5 µm and a wide range of applications.</p>
<p>The post <a href="https://www.rjl-microanalytic.de/en/neues-nanotomographie-system-skyscan-2214/">New SkyScan Nano-CT Enables the Scanning of an Object's Interior</a> first appeared on <a href="https://www.rjl-microanalytic.de/en">RJL Micro &amp; Analytic</a>.</p>]]></description>
		
		
		
			</item>
		<item>
		<title>Revolutionäre Auflösung</title>
		<link>https://www.rjl-microanalytic.de/en/revolutionaere-aufloesung-skyscan-1276/</link>
		
		<dc:creator><![CDATA[Markus J. Heneka]]></dc:creator>
		<pubdate>Thu, 08 Sep 2016 20:00:00 +0000</pubdate>
				<category><![CDATA[Innovative Analytik]]></category>
		<category><![CDATA[Röntgenmikroskopie]]></category>
		<category><![CDATA[Bruker microCT]]></category>
		<category><![CDATA[Micro-CT]]></category>
		<category><![CDATA[Mikrotomographie]]></category>
		<category><![CDATA[Präklinische Bildgebung]]></category>
		<category><![CDATA[Röntgenbildgebung]]></category>
		<category><![CDATA[Röntgentomographie]]></category>
		<category><![CDATA[SkyScan]]></category>
		<guid ispermalink="false">https://new.rjl-microanalytic.de/?p=1348</guid>

					<description><![CDATA[<p>Bruker microCT presented the new SkyScan 1276 in-vivo micro-CT at WMIC 2016. The device sets standards in terms of spatial resolution and scanning speed. fastest scan in 3.9 seconds smallest voxel size 2.8 µm (isotropic) spiral scan mode without ring artifacts The instrument can be operated via touchscreen and offers an on-screen dosimeter.</p>
<p>The post <a href="https://www.rjl-microanalytic.de/en/revolutionaere-aufloesung-skyscan-1276/">Revolutionary Resolution</a> first appeared on <a href="https://www.rjl-microanalytic.de/en">RJL Micro &amp; Analytic</a>.</p>]]></description>
		
		
		
			</item>
		<item>
		<title>SkyScan 1276 Produktvideo</title>
		<link>https://www.rjl-microanalytic.de/en/skyscan-1276-produktvideo/</link>
		
		<dc:creator><![CDATA[Markus J. Heneka]]></dc:creator>
		<pubdate>Thu, 08 Sep 2016 20:00:00 +0000</pubdate>
				<category><![CDATA[Innovative Analytik]]></category>
		<category><![CDATA[Röntgenmikroskopie]]></category>
		<category><![CDATA[Bruker microCT]]></category>
		<category><![CDATA[Micro-CT]]></category>
		<category><![CDATA[Mikrotomographie]]></category>
		<category><![CDATA[Präklinische Bildgebung]]></category>
		<category><![CDATA[Röntgenbildgebung]]></category>
		<category><![CDATA[Röntgentomographie]]></category>
		<category><![CDATA[SkyScan]]></category>
		<guid ispermalink="false">https://new.rjl-microanalytic.de/?p=1350</guid>

					<description><![CDATA[<p>Product video about the new SkyScan 1276. https://www.youtube.com/watch?v=yOseqy8Ogzc</p>
<p>The post <a href="https://www.rjl-microanalytic.de/en/skyscan-1276-produktvideo/">SkyScan 1276 Product Video</a> first appeared on <a href="https://www.rjl-microanalytic.de/en">RJL Micro &amp; Analytic</a>.</p>]]></description>
		
		
		
			</item>
		<item>
		<title>SkyScan 1278 Produktvideo</title>
		<link>https://www.rjl-microanalytic.de/en/skyscan-1278-produktvideo/</link>
					<comments>https://www.rjl-microanalytic.de/en/skyscan-1278-produktvideo/#respond</comments>
		
		<dc:creator><![CDATA[Markus J. Heneka]]></dc:creator>
		<pubdate>Wed, 06 Jan 2016 20:00:27 +0000</pubdate>
				<category><![CDATA[Innovative Analytik]]></category>
		<category><![CDATA[Röntgenmikroskopie]]></category>
		<category><![CDATA[Bruker microCT]]></category>
		<category><![CDATA[Micro-CT]]></category>
		<category><![CDATA[Mikrotomographie]]></category>
		<category><![CDATA[Präklinische Bildgebung]]></category>
		<category><![CDATA[Röntgenbildgebung]]></category>
		<category><![CDATA[Röntgentomographie]]></category>
		<category><![CDATA[SkyScan]]></category>
		<guid ispermalink="false">http://new.rjl-microanalytic.de/?p=1</guid>

					<description><![CDATA[<p>Product video for the new SkyScan 1278. https://www.youtube.com/watch?v=hG9BCkfCW98</p>
<p>The post <a href="https://www.rjl-microanalytic.de/en/skyscan-1278-produktvideo/">SkyScan 1278 Product Video</a> first appeared on <a href="https://www.rjl-microanalytic.de/en">RJL Micro &amp; Analytic</a>.</p>]]></description>
		
					<wfw:commentrss>https://www.rjl-microanalytic.de/en/skyscan-1278-produktvideo/feed/</wfw:commentrss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>