{"id":1188,"date":"2022-01-07T20:08:58","date_gmt":"2022-01-07T19:08:58","guid":{"rendered":"https:\/\/new.rjl-microanalytic.de\/?page_id=1188"},"modified":"2025-07-16T15:52:31","modified_gmt":"2025-07-16T13:52:31","slug":"pruefnormen-pruefvorschriften-restschmutz-technische-sauberkeit","status":"publish","type":"page","link":"https:\/\/www.rjl-microanalytic.de\/en\/restschmutzanalyse-technische-sauberkeit-vda-19-iso-16232\/pruefnormen-pruefvorschriften-restschmutz-technische-sauberkeit\/","title":{"rendered":"Technical cleanliness testing standards"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"1188\" class=\"elementor elementor-1188\" data-elementor-post-type=\"page\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-4e2f0d1 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"4e2f0d1\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-1db6343d\" data-id=\"1db6343d\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-e252b35 elementor-widget elementor-widget-heading\" data-id=\"e252b35\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">NORMGERECHT GEPR\u00dcFT<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1cc29129 elementor-widget elementor-widget-heading\" data-id=\"1cc29129\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Normen &amp; Pr\u00fcfvorschriften, nach denen wir f\u00fcr unsere Kunden arbeiten<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-3c1a90ca elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"3c1a90ca\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-66 elementor-top-column elementor-element elementor-element-28520947\" data-id=\"28520947\" data-element_type=\"column\" data-e-type=\"column\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-66eac9b0 elementor-widget elementor-widget-heading\" data-id=\"66eac9b0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">VDA-19.1 &amp; ISO-16232\u200b<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-63949263 elementor-widget elementor-widget-heading\" data-id=\"63949263\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Grundlegende Normen f\u00fcr Sauberkeitsanalytik<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-da7e1e6 elementor-widget elementor-widget-text-editor\" data-id=\"da7e1e6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Bei der Analyse der Technischen Sauberkeit bilden die Normen VDA-19.1 (2015) und ISO-16232 (2018) einen international anerkannten Rahmen. Nahezu jede Sauberkeitspr\u00fcfung l\u00e4sst sich auf die Methoden in diesen Normtexten zur\u00fcckf\u00fchren.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b4facf7 elementor-widget elementor-widget-heading\" data-id=\"b4facf7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Kundenspezifische Vorschriften<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6987409 elementor-widget elementor-widget-text-editor\" data-id=\"6987409\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Dar\u00fcber hinaus sind bei der Restschmutzanalyse kundenspezifische Spezifikationen, Richtlinien und Pr\u00fcfvorschriften zu beachten. In diesen Texten ist festgelegt, welche Methoden und Pr\u00fcfmittel f\u00fcr das konkrete Bauteil zu verwenden sind und welche Sauberkeitsanforderungen gelten. Das Team unseres Pr\u00fcflabors verf\u00fcgt \u00fcber langj\u00e4hrige Erfahrung und ist mit vielen dieser Texte bereits vertraut.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bb2ea57 elementor-widget elementor-widget-elementskit-tablepress\" data-id=\"bb2ea57\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"elementskit-tablepress.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elemenetskit-tablepress ekit-wid-con\" id=\"ekit_tablepress_bb2ea57\">\n<table id=\"tablepress-2\" class=\"tablepress tablepress-id-2\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\"><strong>Herausgeber<\/strong><\/th><th class=\"column-2\"><strong>Dokumenten-Nummer<\/strong><\/th><th class=\"column-3\"><strong>Titel\/Beschreibung<\/strong><\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">AGCO<\/td><td class=\"column-2\">GF10750201<\/td><td class=\"column-3\">Global Hydraulic Cleanliness Practice<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">Air Liqiude<\/td><td class=\"column-2\">ISO 15001<\/td><td class=\"column-3\">ALMS specifications: control of particulares in line with standard ISO 15001<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">AKF-Staubemissionen<\/td><td class=\"column-2\">NN.<\/td><td class=\"column-3\">EH Ermittlung der AKF-Staubemissionen bei Sp\u00fclvorg\u00e4ngen<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">ASTM International<\/td><td class=\"column-2\">ASTM F30-02<\/td><td class=\"column-3\">Standard practices for sampling for particles in aerospace fluids and components<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">Behr GmbH &amp; Co. KG<\/td><td class=\"column-2\">AA.03301<\/td><td class=\"column-3\">Spezifikation f\u00fcr K\u00fchlmittel-Verdampfer gel\u00f6tet, allgemein<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">Behr GmbH &amp; Co. KG<\/td><td class=\"column-2\">EK-D12<\/td><td class=\"column-3\">Spezifikation Sp\u00fclen &amp; Restschmutzanalyse<\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">Behr GmbH &amp; Co. KG<\/td><td class=\"column-2\">GN AR.01024<\/td><td class=\"column-3\">Fertigungsschmierstoff zur Herstellung von Einzelteilen und Baugruppen innerhalb der Behr Gruppe und bei externen Lieferanten<\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">Behr GmbH &amp; Co. KG<\/td><td class=\"column-2\">GN AR.01024<\/td><td class=\"column-3\">f\u00fcr Aluminium-L\u00f6tung und -Gussteile<\/td>\n<\/tr>\n<tr class=\"row-10\">\n\t<td class=\"column-1\">Behr GmbH &amp; Co. KG<\/td><td class=\"column-2\">GN AR.01107<\/td><td class=\"column-3\">Oberfl\u00e4chenschutzarten f\u00fcr met. Werkstoffe<\/td>\n<\/tr>\n<tr class=\"row-11\">\n\t<td class=\"column-1\">Behr GmbH &amp; Co. KG<\/td><td class=\"column-2\">GN AR:00144<\/td><td class=\"column-3\">Weiche haubengegl\u00fchte AI-Rundrohre aus EN AW-3103 in Ringen<\/td>\n<\/tr>\n<tr class=\"row-12\">\n\t<td class=\"column-1\">Behr GmbH &amp; Co. KG<\/td><td class=\"column-2\">NN.<\/td><td class=\"column-3\">Spezifikation zur Restschmutzanalyse von K\u00fchlern<\/td>\n<\/tr>\n<tr class=\"row-13\">\n\t<td class=\"column-1\">Behr GmbH &amp; Co. KG<\/td><td class=\"column-2\">PML 00419<\/td><td class=\"column-3\">Montage der Sammelrohre<\/td>\n<\/tr>\n<tr class=\"row-14\">\n\t<td class=\"column-1\">Behr GmbH &amp; Co. KG<\/td><td class=\"column-2\">PN AR.01006<\/td><td class=\"column-3\">Festigkeitspr\u00fcfung<\/td>\n<\/tr>\n<tr class=\"row-15\">\n\t<td class=\"column-1\">Behr GmbH &amp; Co. KG<\/td><td class=\"column-2\">PN AR.01042<\/td><td class=\"column-3\">Restschmierstoffgehaltes auf met. Werkstoffoberfl\u00e4chen<\/td>\n<\/tr>\n<tr class=\"row-16\">\n\t<td class=\"column-1\">BERU<\/td><td class=\"column-2\">STN 400<\/td><td class=\"column-3\">Pr\u00fcfnorm f\u00fcr metallische Eigenfertigungs-und Zuliererteile<\/td>\n<\/tr>\n<tr class=\"row-17\">\n\t<td class=\"column-1\">BKA<\/td><td class=\"column-2\">doc00981120120724112202<\/td><td class=\"column-3\">Pr\u00fcfvorschrift f\u00fcr Analyse von Schmauchr\u00fcckst\u00e4nden<\/td>\n<\/tr>\n<tr class=\"row-18\">\n\t<td class=\"column-1\">BMW AG<\/td><td class=\"column-2\">10274837-000-03<\/td><td class=\"column-3\">Flussmittelanforderungen<\/td>\n<\/tr>\n<tr class=\"row-19\">\n\t<td class=\"column-1\">BMW AG<\/td><td class=\"column-2\">10274837-000-03<\/td><td class=\"column-3\">Technische Sauberkeit<\/td>\n<\/tr>\n<tr class=\"row-20\">\n\t<td class=\"column-1\">BMW AG<\/td><td class=\"column-2\">10274837-000-03<\/td><td class=\"column-3\">K\u00fchlmodul LU<\/td>\n<\/tr>\n<tr class=\"row-21\">\n\t<td class=\"column-1\">BMW AG<\/td><td class=\"column-2\">10283184-000-03<\/td><td class=\"column-3\">K\u00e4ltemittelverdichter<\/td>\n<\/tr>\n<tr class=\"row-22\">\n\t<td class=\"column-1\">BMW AG<\/td><td class=\"column-2\">10325731-000-02<\/td><td class=\"column-3\">K\u00fchlmodul I12<\/td>\n<\/tr>\n<tr class=\"row-23\">\n\t<td class=\"column-1\">BMW AG<\/td><td class=\"column-2\">DID-DE-0146605<\/td><td class=\"column-3\">Allg. Regelung zur Pr\u00fcfung der Technischen Sauberkeit<\/td>\n<\/tr>\n<tr class=\"row-24\">\n\t<td class=\"column-1\">BMW AG<\/td><td class=\"column-2\">DIN73411-2<\/td><td class=\"column-3\">Hoses and compounds<\/td>\n<\/tr>\n<tr class=\"row-25\">\n\t<td class=\"column-1\">BMW AG<\/td><td class=\"column-2\">Dokumentennumer: 4829087<\/td><td class=\"column-3\">BMW Qualit\u00e4tsvorschrift: 4829087<\/td>\n<\/tr>\n<tr class=\"row-26\">\n\t<td class=\"column-1\">BMW AG<\/td><td class=\"column-2\">EA 3.1.11<\/td><td class=\"column-3\">Ermittlung der Partikel aus Aktivkohlefilter<\/td>\n<\/tr>\n<tr class=\"row-27\">\n\t<td class=\"column-1\">BMW AG<\/td><td class=\"column-2\">LH 111811386-000-00<\/td><td class=\"column-3\">Klimakondensator (wassergek\u00fchlt) CLAR WE<\/td>\n<\/tr>\n<tr class=\"row-28\">\n\t<td class=\"column-1\">BMW AG<\/td><td class=\"column-2\">PR620<\/td><td class=\"column-3\">Technische Sauberkeit Lagerschalen <\/td>\n<\/tr>\n<tr class=\"row-29\">\n\t<td class=\"column-1\">BMW AG<\/td><td class=\"column-2\">QV11111<\/td><td class=\"column-3\">Technische Sauberkeit Zylinderkopfdichtungen N55<\/td>\n<\/tr>\n<tr class=\"row-30\">\n\t<td class=\"column-1\">BMW AG<\/td><td class=\"column-2\">QV11111<\/td><td class=\"column-3\">Technische Sauberkeit<\/td>\n<\/tr>\n<tr class=\"row-31\">\n\t<td class=\"column-1\">BMW AG<\/td><td class=\"column-2\">QV11111<\/td><td class=\"column-3\">Technische Sauberkeit<\/td>\n<\/tr>\n<tr class=\"row-32\">\n\t<td class=\"column-1\">BMW AG<\/td><td class=\"column-2\">QV11111<\/td><td class=\"column-3\">Technische Sauberkeit<\/td>\n<\/tr>\n<tr class=\"row-33\">\n\t<td class=\"column-1\">BMW AG<\/td><td class=\"column-2\">QV11111<\/td><td class=\"column-3\">Anforderungsrechte Technische Sauberkeit von Bauteilen und Fluiden in BMW Antrieben<\/td>\n<\/tr>\n<tr class=\"row-34\">\n\t<td class=\"column-1\">BMW AG<\/td><td class=\"column-2\">QV17004<\/td><td class=\"column-3\">K\u00fchlmittelkreislauf Ausgleichsbeh\u00e4lter<\/td>\n<\/tr>\n<tr class=\"row-35\">\n\t<td class=\"column-1\">BMW AG<\/td><td class=\"column-2\">QV17006<\/td><td class=\"column-3\">Bauteile im K\u00fchlmittelkreislauf<\/td>\n<\/tr>\n<tr class=\"row-36\">\n\t<td class=\"column-1\">BMW AG<\/td><td class=\"column-2\">QV32032<\/td><td class=\"column-3\">\u00d6lbeh\u00e4lter f\u00fcr LH und ARS<\/td>\n<\/tr>\n<tr class=\"row-37\">\n\t<td class=\"column-1\">BMW AG<\/td><td class=\"column-2\">QV33019<\/td><td class=\"column-3\">Vorder- und Hinterachsgetriebe<\/td>\n<\/tr>\n<tr class=\"row-38\">\n\t<td class=\"column-1\">BMW AG<\/td><td class=\"column-2\">QV33019<\/td><td class=\"column-3\">TecSa f\u00fcr BMW Achs- und E-Getriebe<\/td>\n<\/tr>\n<tr class=\"row-39\">\n\t<td class=\"column-1\">BMW AG<\/td><td class=\"column-2\">QV64005<\/td><td class=\"column-3\">K\u00e4ltemittel-Leitungen<\/td>\n<\/tr>\n<tr class=\"row-40\">\n\t<td class=\"column-1\">BMW AG<\/td><td class=\"column-2\">QV64037<\/td><td class=\"column-3\">Kondensator<\/td>\n<\/tr>\n<tr class=\"row-41\">\n\t<td class=\"column-1\">BMW AG<\/td><td class=\"column-2\">QV64044<\/td><td class=\"column-3\">Trockner<\/td>\n<\/tr>\n<tr class=\"row-42\">\n\t<td class=\"column-1\">BMW Group<\/td><td class=\"column-2\">PR 608.1<\/td><td class=\"column-3\">Pr\u00fcfung der technischen Sauberkeit von luftf\u00fchrenden Bauteilen mit Luft<\/td>\n<\/tr>\n<tr class=\"row-43\">\n\t<td class=\"column-1\">BMW Group<\/td><td class=\"column-2\">QV11111<\/td><td class=\"column-3\">Anforderungsrechte Technische Sauberkeit von Bauteilen und Fluiden in BMW Antrieben<\/td>\n<\/tr>\n<tr class=\"row-44\">\n\t<td class=\"column-1\">BMW, Ford, Bosch, MAN<\/td><td class=\"column-2\">NN.<\/td><td class=\"column-3\">Kundenanforderung an Dieselkraftstofffilter<\/td>\n<\/tr>\n<tr class=\"row-45\">\n\t<td class=\"column-1\">Borg Warner<\/td><td class=\"column-2\">APN-002-F<\/td><td class=\"column-3\">Sauberkeit von Getriebeteilen<\/td>\n<\/tr>\n<tr class=\"row-46\">\n\t<td class=\"column-1\">Borg Warner<\/td><td class=\"column-2\">APN-096<\/td><td class=\"column-3\">Sauberkeit von Getriebeteilen<\/td>\n<\/tr>\n<tr class=\"row-47\">\n\t<td class=\"column-1\">Borg Warner<\/td><td class=\"column-2\">BWS 42001<\/td><td class=\"column-3\">Sauberkeit von Abgasturboladern<\/td>\n<\/tr>\n<tr class=\"row-48\">\n\t<td class=\"column-1\">Borg Warner<\/td><td class=\"column-2\">ES60011<\/td><td class=\"column-3\">Cleanliness Specification<\/td>\n<\/tr>\n<tr class=\"row-49\">\n\t<td class=\"column-1\">Borg Warner<\/td><td class=\"column-2\">STN 400<\/td><td class=\"column-3\">Pr\u00fcfnorm f\u00fcr metallische Eigenfertigungs-und Zuliererteile<\/td>\n<\/tr>\n<tr class=\"row-50\">\n\t<td class=\"column-1\">Bosch Mahle Turbosystems<\/td><td class=\"column-2\">N-PS-001<\/td><td class=\"column-3\">Technische Sauberkeit<\/td>\n<\/tr>\n<tr class=\"row-51\">\n\t<td class=\"column-1\">Bosch Mahle Turbosystems<\/td><td class=\"column-2\">N-PS-001 Anlage 2<\/td><td class=\"column-3\">Technische Sauberkeit Anlage 2<\/td>\n<\/tr>\n<tr class=\"row-52\">\n\t<td class=\"column-1\">Bosch Mahle Turbosystems<\/td><td class=\"column-2\">N-PS-001 Anlage 3<\/td><td class=\"column-3\">Technische Sauberkeit Anlage 3<\/td>\n<\/tr>\n<tr class=\"row-53\">\n\t<td class=\"column-1\">Borg Warner<\/td><td class=\"column-2\">S-1164<\/td><td class=\"column-3\">Component Cleanlinesss Specification<\/td>\n<\/tr>\n<tr class=\"row-54\">\n\t<td class=\"column-1\">Brose<\/td><td class=\"column-2\">6606401101<\/td><td class=\"column-3\">Technische Sauberkeit: Pr\u00fcfspezifikation f\u00fcr Kleinteile<\/td>\n<\/tr>\n<tr class=\"row-55\">\n\t<td class=\"column-1\">Brose<\/td><td class=\"column-2\">6606401101<\/td><td class=\"column-3\">Pr\u00fcfspezifikation: Restschmutzpr\u00fcfung von Produkten, Kaufteilen und Verpackungen<\/td>\n<\/tr>\n<tr class=\"row-56\">\n\t<td class=\"column-1\">Brose<\/td><td class=\"column-2\">591222-101<\/td><td class=\"column-3\">Technische Sauberkeit in der Logistik \/ Technical Cleanliness in Logistcs<\/td>\n<\/tr>\n<tr class=\"row-57\">\n\t<td class=\"column-1\">Brose<\/td><td class=\"column-2\">591242-103 Teil 1<\/td><td class=\"column-3\">Norm \/ Standard Pr\u00fcfung der technischen Sauberkeit an Produkte, Kaufteilen und Verp.<\/td>\n<\/tr>\n<tr class=\"row-58\">\n\t<td class=\"column-1\">Brose<\/td><td class=\"column-2\">6606070201-02<\/td><td class=\"column-3\">Erg\u00e4nzende Vorschrift<\/td>\n<\/tr>\n<tr class=\"row-59\">\n\t<td class=\"column-1\">Brose<\/td><td class=\"column-2\">6606070201-03<\/td><td class=\"column-3\">Restschmutzpr\u00fcfung von Produkten, Kaufteilen, Verpackungen<\/td>\n<\/tr>\n<tr class=\"row-60\">\n\t<td class=\"column-1\">Caterpillar Inc. CAT<\/td><td class=\"column-2\">INF<\/td><td class=\"column-3\">CLEANLINESS \u2013 TUBES AND TUBE ASSEMBLIES<\/td>\n<\/tr>\n<tr class=\"row-61\">\n\t<td class=\"column-1\">Caterpillar Inc. CAT<\/td><td class=\"column-2\">INF<\/td><td class=\"column-3\">Cleanliness - Finished Engine Components<\/td>\n<\/tr>\n<tr class=\"row-62\">\n\t<td class=\"column-1\">Caterpillar Inc. CAT<\/td><td class=\"column-2\">INF<\/td><td class=\"column-3\">CLEANLINESS \u2013 PIECE PART<\/td>\n<\/tr>\n<tr class=\"row-63\">\n\t<td class=\"column-1\">Continental<\/td><td class=\"column-2\">N 002 02.22<\/td><td class=\"column-3\">Produktspezifikation \/ Product Specification von Bremsaggregaten und montagefertigen Einzelteilen<\/td>\n<\/tr>\n<tr class=\"row-64\">\n\t<td class=\"column-1\">Continental<\/td><td class=\"column-2\">TST N 002 02.20<\/td><td class=\"column-3\">Standard for Product Cleanliness<\/td>\n<\/tr>\n<tr class=\"row-65\">\n\t<td class=\"column-1\">Continental<\/td><td class=\"column-2\">TST N002 02.20<\/td><td class=\"column-3\">Standard zur Produktsauberkeit Bauteile und Baugruppen<\/td>\n<\/tr>\n<tr class=\"row-66\">\n\t<td class=\"column-1\">Continental<\/td><td class=\"column-2\">TST N002 02.21<\/td><td class=\"column-3\">Standard for product cleanliness for electronical drives<\/td>\n<\/tr>\n<tr class=\"row-67\">\n\t<td class=\"column-1\">Continental ContiTemic<\/td><td class=\"column-2\">10098907QDO000AC<\/td><td class=\"column-3\">General Qualitiy Requirements<\/td>\n<\/tr>\n<tr class=\"row-68\">\n\t<td class=\"column-1\">Continental ContiTemic<\/td><td class=\"column-2\">N.002.02.00<\/td><td class=\"column-3\">Fragenkatalog <\/td>\n<\/tr>\n<tr class=\"row-69\">\n\t<td class=\"column-1\">Continental ContiTemic<\/td><td class=\"column-2\">N.002.02.20.20<\/td><td class=\"column-3\">Standard zur Produktsauberkeit Bauteile und Baugruppen<\/td>\n<\/tr>\n<tr class=\"row-70\">\n\t<td class=\"column-1\">Continental ContiTemic<\/td><td class=\"column-2\">N.002.02.21<\/td><td class=\"column-3\">Standard for technical clenliness-power electronics for electrical drives<\/td>\n<\/tr>\n<tr class=\"row-71\">\n\t<td class=\"column-1\">Continental ContiTemic<\/td><td class=\"column-2\">N.002.02.22<\/td><td class=\"column-3\">Produktspezifikation<\/td>\n<\/tr>\n<tr class=\"row-72\">\n\t<td class=\"column-1\">Continental ContiTemic<\/td><td class=\"column-2\">N.543.80.03<\/td><td class=\"column-3\">Produktspezifikation Sauberkeit von montagefertigen Einzelteilen<\/td>\n<\/tr>\n<tr class=\"row-73\">\n\t<td class=\"column-1\">Continental ContiTemic<\/td><td class=\"column-2\">N002.02.40<\/td><td class=\"column-3\">Standard for product cleanliness <\/td>\n<\/tr>\n<tr class=\"row-74\">\n\t<td class=\"column-1\">Continental ContiTemic<\/td><td class=\"column-2\">N002.02.40<\/td><td class=\"column-3\">Qualification of the procedure Adhesive Tape<\/td>\n<\/tr>\n<tr class=\"row-75\">\n\t<td class=\"column-1\">Continental ContiTemic<\/td><td class=\"column-2\">S0330<\/td><td class=\"column-3\">Technical Specification<\/td>\n<\/tr>\n<tr class=\"row-76\">\n\t<td class=\"column-1\">Continental ContiTemic<\/td><td class=\"column-2\">TML28.4003-9700.1<\/td><td class=\"column-3\">Bondrahmen<\/td>\n<\/tr>\n<tr class=\"row-77\">\n\t<td class=\"column-1\">Continental, VDO<\/td><td class=\"column-2\">10098907QDO000AB<\/td><td class=\"column-3\">General Quality Requirements<\/td>\n<\/tr>\n<tr class=\"row-78\">\n\t<td class=\"column-1\">Continental, VDO<\/td><td class=\"column-2\">10098907QDO000AC<\/td><td class=\"column-3\">General Quality Requirements<\/td>\n<\/tr>\n<tr class=\"row-79\">\n\t<td class=\"column-1\">Continental, VDO<\/td><td class=\"column-2\">660.60702.01<\/td><td class=\"column-3\">Gravimetrische Restschmutzpr\u00fcfung von Bauteilen<\/td>\n<\/tr>\n<tr class=\"row-80\">\n\t<td class=\"column-1\">Continental, VDO<\/td><td class=\"column-2\">A2C20003304AAJ a<\/td><td class=\"column-3\">Sauberkeitspr\u00fcfung VCV<\/td>\n<\/tr>\n<tr class=\"row-81\">\n\t<td class=\"column-1\">Continental, VDO<\/td><td class=\"column-2\">A2C20003496AAJ a<\/td><td class=\"column-3\">Gravimetrische Restschmutzpr\u00fcfung von Bauteilen<\/td>\n<\/tr>\n<tr class=\"row-82\">\n\t<td class=\"column-1\">Continental, VDO<\/td><td class=\"column-2\">ATE N543.80.03<\/td><td class=\"column-3\">Innensauberkeit von Bremsaggregaten<\/td>\n<\/tr>\n<tr class=\"row-83\">\n\t<td class=\"column-1\">Continental, VDO<\/td><td class=\"column-2\">SN 52820<\/td><td class=\"column-3\">zul\u00e4ssige Verunreinigung<\/td>\n<\/tr>\n<tr class=\"row-84\">\n\t<td class=\"column-1\">Continental, VDO<\/td><td class=\"column-2\">TST N002.02.21<\/td><td class=\"column-3\">Standard for product cleanliness<\/td>\n<\/tr>\n<tr class=\"row-85\">\n\t<td class=\"column-1\">Continental, VDO<\/td><td class=\"column-2\">TST N002.02.22-2<\/td><td class=\"column-3\">Internal cleanliness<\/td>\n<\/tr>\n<tr class=\"row-86\">\n\t<td class=\"column-1\">Continental, VDO<\/td><td class=\"column-2\">TST N002.02.55.00-1<\/td><td class=\"column-3\">Cleanliness Inspection Armature<\/td>\n<\/tr>\n<tr class=\"row-87\">\n\t<td class=\"column-1\">Continental, VDO<\/td><td class=\"column-2\">TST N002.02.55.00-2<\/td><td class=\"column-3\">Inspection Tooling Armature<\/td>\n<\/tr>\n<tr class=\"row-88\">\n\t<td class=\"column-1\">Continental, VDO<\/td><td class=\"column-2\">TST N002.02.55.00-3<\/td><td class=\"column-3\">Extraction Procedure Armature<\/td>\n<\/tr>\n<tr class=\"row-89\">\n\t<td class=\"column-1\">Continental, VDO<\/td><td class=\"column-2\">TST N002.02_00-031-09_09_2019-en<\/td><td class=\"column-3\">Standard for product cleanliness<\/td>\n<\/tr>\n<tr class=\"row-90\">\n\t<td class=\"column-1\">Continental, VDO<\/td><td class=\"column-2\">TST_N_002_02_22_Sh-004_MKC1<\/td><td class=\"column-3\">Internal cleanliness<\/td>\n<\/tr>\n<tr class=\"row-91\">\n\t<td class=\"column-1\">Continetal,Siemens<\/td><td class=\"column-2\">660.60702.01<\/td><td class=\"column-3\">Pr\u00fcfspezifikation: gravimetrische Restscgmutzpr\u00fcfung von Bauteilen<\/td>\n<\/tr>\n<tr class=\"row-92\">\n\t<td class=\"column-1\">Cummins<\/td><td class=\"column-2\">16233<\/td><td class=\"column-3\">Cleanliness Millipore<\/td>\n<\/tr>\n<tr class=\"row-93\">\n\t<td class=\"column-1\">Cummins<\/td><td class=\"column-2\">16599<\/td><td class=\"column-3\">Cleanless particle counting<\/td>\n<\/tr>\n<tr class=\"row-94\">\n\t<td class=\"column-1\">Cummins<\/td><td class=\"column-2\">ISO<\/td><td class=\"column-3\">Cleanliness Training<\/td>\n<\/tr>\n<tr class=\"row-95\">\n\t<td class=\"column-1\">DAF<\/td><td class=\"column-2\">TKB 00804-102 P<\/td><td class=\"column-3\">Cleanliness of Products<\/td>\n<\/tr>\n<tr class=\"row-96\">\n\t<td class=\"column-1\">Daimler<\/td><td class=\"column-2\">020.DC.00298<\/td><td class=\"column-3\">Sauberkeitsanforderungen Motoren<\/td>\n<\/tr>\n<tr class=\"row-97\">\n\t<td class=\"column-1\">Daimler<\/td><td class=\"column-2\">A0030025199<\/td><td class=\"column-3\">Hydraulik Federungssystem Anforderungen und Pr\u00fcfvorschrift Reinheit<\/td>\n<\/tr>\n<tr class=\"row-98\">\n\t<td class=\"column-1\">Daimler<\/td><td class=\"column-2\">A9300019599<\/td><td class=\"column-3\">Reinheit Druckluft-Kmponenten<\/td>\n<\/tr>\n<tr class=\"row-99\">\n\t<td class=\"column-1\">Daimler<\/td><td class=\"column-2\">BR 725.0 NAG3<\/td><td class=\"column-3\">Twchnik-Komponentenlastenheft<\/td>\n<\/tr>\n<tr class=\"row-100\">\n\t<td class=\"column-1\">Daimler<\/td><td class=\"column-2\">DBL 6515<\/td><td class=\"column-3\">Bestimmung Technische Sauberkeit<\/td>\n<\/tr>\n<tr class=\"row-101\">\n\t<td class=\"column-1\">Daimler<\/td><td class=\"column-2\">DBL 6516<\/td><td class=\"column-3\">Festlegung Restschmutzgrenzwerte<\/td>\n<\/tr>\n<tr class=\"row-102\">\n\t<td class=\"column-1\">Daimler<\/td><td class=\"column-2\">DBL 6516 EN<\/td><td class=\"column-3\">Specification of Residual Dirt Limit Values<\/td>\n<\/tr>\n<tr class=\"row-103\">\n\t<td class=\"column-1\">Daimler<\/td><td class=\"column-2\">DBL 6575<\/td><td class=\"column-3\">Restschmutzuntersuchung Common-Rail-Leitungen<\/td>\n<\/tr>\n<tr class=\"row-104\">\n\t<td class=\"column-1\">Daimler<\/td><td class=\"column-2\">MGU00001331<\/td><td class=\"column-3\">Spezifikation innerer Reinheit f\u00fcr alle K\u00e4ltekreislauf (KKL)-Komponenten<\/td>\n<\/tr>\n<tr class=\"row-105\">\n\t<td class=\"column-1\">Daimler<\/td><td class=\"column-2\">MGU00001331<\/td><td class=\"column-3\">Spezifikation innerer Reinheit f\u00fcr alle K\u00e4ltekreislauf (KKL)-Komponenten<\/td>\n<\/tr>\n<tr class=\"row-106\">\n\t<td class=\"column-1\">Daimler<\/td><td class=\"column-2\">QS 64005 <\/td><td class=\"column-3\">Water content and technical cleanliness<\/td>\n<\/tr>\n<tr class=\"row-107\">\n\t<td class=\"column-1\">Daimler<\/td><td class=\"column-2\">VAAM00328 PI00942<\/td><td class=\"column-3\">Cleanliness requirements<\/td>\n<\/tr>\n<tr class=\"row-108\">\n\t<td class=\"column-1\">Daimler<\/td><td class=\"column-2\">VAAM00328 PI00942<\/td><td class=\"column-3\">Sauberkeitsvorlage<\/td>\n<\/tr>\n<tr class=\"row-109\">\n\t<td class=\"column-1\">Daimler<\/td><td class=\"column-2\">VAM00328<\/td><td class=\"column-3\">Sauberkeitsvorgaben<\/td>\n<\/tr>\n<tr class=\"row-110\">\n\t<td class=\"column-1\">Daimler<\/td><td class=\"column-2\">VAM328<\/td><td class=\"column-3\">Sauberkeitsanforderungen<\/td>\n<\/tr>\n<tr class=\"row-111\">\n\t<td class=\"column-1\">Danfoss<\/td><td class=\"column-2\">504H0086<\/td><td class=\"column-3\">Cleanliness for Production Parts and Subassemblies<\/td>\n<\/tr>\n<tr class=\"row-112\">\n\t<td class=\"column-1\">Delphi<\/td><td class=\"column-2\">4130052<\/td><td class=\"column-3\">Product Cleanliness<\/td>\n<\/tr>\n<tr class=\"row-113\">\n\t<td class=\"column-1\">Delphi<\/td><td class=\"column-2\">41300052<\/td><td class=\"column-3\">Product Cleanliness<\/td>\n<\/tr>\n<tr class=\"row-114\">\n\t<td class=\"column-1\">Delphi<\/td><td class=\"column-2\">10356669-000-01<\/td><td class=\"column-3\">Grenzwerte Partikelanzahl\/-gr\u00f6\u00dfe bezogen auf Komponenten<\/td>\n<\/tr>\n<tr class=\"row-115\">\n\t<td class=\"column-1\">Deutscher Schrauben-Verband<\/td><td class=\"column-2\">NN.<\/td><td class=\"column-3\">Richtlinie: Sauberkeit von Schrauben f\u00fcr die Automobilindustrie<\/td>\n<\/tr>\n<tr class=\"row-116\">\n\t<td class=\"column-1\">Deutz-Fahr Italia<\/td><td class=\"column-2\">92349<\/td><td class=\"column-3\">Cleaning of Hydraulic Components<\/td>\n<\/tr>\n<tr class=\"row-117\">\n\t<td class=\"column-1\">Deutz-Fahr Italia<\/td><td class=\"column-2\">92362<\/td><td class=\"column-3\">Cleaning of Engine Components<\/td>\n<\/tr>\n<tr class=\"row-118\">\n\t<td class=\"column-1\">Deutz-Fahr Italia<\/td><td class=\"column-2\">LV 0161 0252<\/td><td class=\"column-3\">Sauberkeit von Bauteilen<\/td>\n<\/tr>\n<tr class=\"row-119\">\n\t<td class=\"column-1\">Deutz-Fahr Italia<\/td><td class=\"column-2\">PV 0162 0069<\/td><td class=\"column-3\">Sauberkeit von Bauteilen<\/td>\n<\/tr>\n<tr class=\"row-120\">\n\t<td class=\"column-1\">Deutz-Fahr Italia<\/td><td class=\"column-2\">PV 01620080<\/td><td class=\"column-3\">Sauberkeit von Bauteilen<\/td>\n<\/tr>\n<tr class=\"row-121\">\n\t<td class=\"column-1\">DIN <\/td><td class=\"column-2\">DIN 8905<\/td><td class=\"column-3\">Rohre f\u00fcr K\u00e4lteanlagen mit hermetischen und halbhermetischen Verdichtern<\/td>\n<\/tr>\n<tr class=\"row-122\">\n\t<td class=\"column-1\">DIN\/EN\/ISO<\/td><td class=\"column-2\">DIN 8949<\/td><td class=\"column-3\">Filtertrockner f\u00fcr K\u00e4ltemittel Pr\u00fcfung<\/td>\n<\/tr>\n<tr class=\"row-123\">\n\t<td class=\"column-1\">DIN\/EN\/ISO<\/td><td class=\"column-2\">DIN 8964-1\/ DIN 51455<\/td><td class=\"column-3\">Kreislaufteile f\u00fcr K\u00e4lteanlagen, Pr\u00fcfung<\/td>\n<\/tr>\n<tr class=\"row-124\">\n\t<td class=\"column-1\">DIN\/EN\/ISO<\/td><td class=\"column-2\">DIN 8964-2<\/td><td class=\"column-3\">Kreislaufteile f\u00fcr K\u00e4lteanlagen, Anforderung<\/td>\n<\/tr>\n<tr class=\"row-125\">\n\t<td class=\"column-1\">DIN\/EN\/ISO<\/td><td class=\"column-2\">DIN 8964-3<\/td><td class=\"column-3\">Kreislaufteile f\u00fcr K\u00e4lteanlagen, Anforderung<\/td>\n<\/tr>\n<tr class=\"row-126\">\n\t<td class=\"column-1\">DIN\/EN\/ISO<\/td><td class=\"column-2\">DIN EN 10247<\/td><td class=\"column-3\">metallographische Pr\u00fcfung nichtmetallischer Einschl\u00fcsse in Stahl<\/td>\n<\/tr>\n<tr class=\"row-127\">\n\t<td class=\"column-1\">DIN\/EN\/ISO<\/td><td class=\"column-2\">DIN EN 15001<\/td><td class=\"column-3\">An\u00e4sthesie und Beatmungsger\u00e4te<\/td>\n<\/tr>\n<tr class=\"row-128\">\n\t<td class=\"column-1\">DIN\/EN\/ISO<\/td><td class=\"column-2\">DIN EN ISO\/IEC 17025<\/td><td class=\"column-3\">Anforderungen an die Kompetenz von Pr\u00fcflaboren<\/td>\n<\/tr>\n<tr class=\"row-129\">\n\t<td class=\"column-1\">DIN\/EN\/ISO<\/td><td class=\"column-2\">DIN EN45502-1<\/td><td class=\"column-3\">Aktive implantierbare medizinische Ger\u00e4te<\/td>\n<\/tr>\n<tr class=\"row-130\">\n\t<td class=\"column-1\">DIN\/EN\/ISO<\/td><td class=\"column-2\">DIN51455<\/td><td class=\"column-3\">Bestimmung der Partikelanzahl und Partikelgr\u00f6\u00dfen in \u00d6len<\/td>\n<\/tr>\n<tr class=\"row-131\">\n\t<td class=\"column-1\">DIN\/EN\/ISO<\/td><td class=\"column-2\">ISO-16232 (Part1-10)<\/td><td class=\"column-3\">road vehicles, cleanliness of components of fluid circuits<\/td>\n<\/tr>\n<tr class=\"row-132\">\n\t<td class=\"column-1\">DIN\/EN\/ISO<\/td><td class=\"column-2\">ISO-4405<\/td><td class=\"column-3\">hydraulic fluid contamination, gravimetric method<\/td>\n<\/tr>\n<tr class=\"row-133\">\n\t<td class=\"column-1\">DIN\/EN\/ISO<\/td><td class=\"column-2\">ISO-4406<\/td><td class=\"column-3\">hydraulic fluid contamination, coding the level of centamination<\/td>\n<\/tr>\n<tr class=\"row-134\">\n\t<td class=\"column-1\">EATON<\/td><td class=\"column-2\">ATS-349<\/td><td class=\"column-3\">Engineering Standard<\/td>\n<\/tr>\n<tr class=\"row-135\">\n\t<td class=\"column-1\">Ebersp\u00e4cher<\/td><td class=\"column-2\">CN 102 <\/td><td class=\"column-3\">Technische Sauberkeit<\/td>\n<\/tr>\n<tr class=\"row-136\">\n\t<td class=\"column-1\">Ebersp\u00e4cher<\/td><td class=\"column-2\">CN 102 <\/td><td class=\"column-3\">Technische Sauberkeit<\/td>\n<\/tr>\n<tr class=\"row-137\">\n\t<td class=\"column-1\">Ebersp\u00e4cher<\/td><td class=\"column-2\">CN 102 <\/td><td class=\"column-3\">Technische Sauberkeit<\/td>\n<\/tr>\n<tr class=\"row-138\">\n\t<td class=\"column-1\">Ebersp\u00e4cher<\/td><td class=\"column-2\">CN 102 <\/td><td class=\"column-3\">Technische Sauberkeit<\/td>\n<\/tr>\n<tr class=\"row-139\">\n\t<td class=\"column-1\">Ebersp\u00e4cher<\/td><td class=\"column-2\">JE-Norm 6.30000<\/td><td class=\"column-3\">Technische Sauberkeit<\/td>\n<\/tr>\n<tr class=\"row-140\">\n\t<td class=\"column-1\">EmiTec<\/td><td class=\"column-2\">DBE733<\/td><td class=\"column-3\">SCR Cleanliness specification<\/td>\n<\/tr>\n<tr class=\"row-141\">\n\t<td class=\"column-1\">EM-motive GmbH <\/td><td class=\"column-2\">F03Z.Y00.397<\/td><td class=\"column-3\">Test Specification<\/td>\n<\/tr>\n<tr class=\"row-142\">\n\t<td class=\"column-1\">EM-motive GmbH <\/td><td class=\"column-2\">F03Z.Y00.410<\/td><td class=\"column-3\">Test Specification<\/td>\n<\/tr>\n<tr class=\"row-143\">\n\t<td class=\"column-1\">Endress + Hauser<\/td><td class=\"column-2\">50108447<\/td><td class=\"column-3\">Cleanliness Standard for stainless steel\/ corrosion-resistant<\/td>\n<\/tr>\n<tr class=\"row-144\">\n\t<td class=\"column-1\">ETO<\/td><td class=\"column-2\">100010936_Z25_000<\/td><td class=\"column-3\">Pr\u00fcfung technische Sauberkeit<\/td>\n<\/tr>\n<tr class=\"row-145\">\n\t<td class=\"column-1\">ETO<\/td><td class=\"column-2\">100010936_Z25_001<\/td><td class=\"column-3\">Testing technical cleanliness<\/td>\n<\/tr>\n<tr class=\"row-146\">\n\t<td class=\"column-1\">European Commission<\/td><td class=\"column-2\">2011R0010 EN<\/td><td class=\"column-3\">Commission Regulation<\/td>\n<\/tr>\n<tr class=\"row-147\">\n\t<td class=\"column-1\">European Commission<\/td><td class=\"column-2\">No 10\/2011 EN<\/td><td class=\"column-3\">Union Guidane on Regulation EN<\/td>\n<\/tr>\n<tr class=\"row-148\">\n\t<td class=\"column-1\">Fiat<\/td><td class=\"column-2\">2402<\/td><td class=\"column-3\">Engineering Specifications<\/td>\n<\/tr>\n<tr class=\"row-149\">\n\t<td class=\"column-1\">Fiat<\/td><td class=\"column-2\">86620212<\/td><td class=\"column-3\">Significant characteristics spec<\/td>\n<\/tr>\n<tr class=\"row-150\">\n\t<td class=\"column-1\">Fiat<\/td><td class=\"column-2\">7.G2183<\/td><td class=\"column-3\">Determining the Impurities inside Components of Fluid Circulation Systems<\/td>\n<\/tr>\n<tr class=\"row-151\">\n\t<td class=\"column-1\">Fiat<\/td><td class=\"column-2\">7-G0200<\/td><td class=\"column-3\">Determining the Impurities inside Components of Fluid Circulation Systems<\/td>\n<\/tr>\n<tr class=\"row-152\">\n\t<td class=\"column-1\">Fiat<\/td><td class=\"column-2\">9.021139\/01<\/td><td class=\"column-3\">FLEXIBLE RUBBER SLEEVES FOR CONVEYING BLOW-BY VAPOURS FOR DIESEL ENGINES<\/td>\n<\/tr>\n<tr class=\"row-153\">\n\t<td class=\"column-1\">Fiat<\/td><td class=\"column-2\">FPT.MAN050<\/td><td class=\"column-3\">Detection of Impurities in Production<\/td>\n<\/tr>\n<tr class=\"row-154\">\n\t<td class=\"column-1\">Fiat<\/td><td class=\"column-2\">FPT.MAN050<\/td><td class=\"column-3\">Detection of Impurities in Production<\/td>\n<\/tr>\n<tr class=\"row-155\">\n\t<td class=\"column-1\">Ford<\/td><td class=\"column-2\">EN00E12185422000<\/td><td class=\"column-3\">Engineering Specification<\/td>\n<\/tr>\n<tr class=\"row-156\">\n\t<td class=\"column-1\">Ford<\/td><td class=\"column-2\">ES-7T4E-6B616-AA<\/td><td class=\"column-3\">Engine Oil Pump System Contamination<\/td>\n<\/tr>\n<tr class=\"row-157\">\n\t<td class=\"column-1\">Ford<\/td><td class=\"column-2\">ESAG9G-9370-AA<\/td><td class=\"column-3\">Engineering Specification<\/td>\n<\/tr>\n<tr class=\"row-158\">\n\t<td class=\"column-1\">Ford<\/td><td class=\"column-2\">ESBC3P-7W092-BA<\/td><td class=\"column-3\">TDE Contamination Specification<\/td>\n<\/tr>\n<tr class=\"row-159\">\n\t<td class=\"column-1\">Ford<\/td><td class=\"column-2\">ESCM5G-6059-GA<\/td><td class=\"column-3\">Engineering Specification<\/td>\n<\/tr>\n<tr class=\"row-160\">\n\t<td class=\"column-1\">Ford<\/td><td class=\"column-2\">ESECPC-3D070-AC<\/td><td class=\"column-3\">Engineering Specification<\/td>\n<\/tr>\n<tr class=\"row-161\">\n\t<td class=\"column-1\">Ford<\/td><td class=\"column-2\">ESJ1KP-7W092-AA<\/td><td class=\"column-3\">Engineering Specification<\/td>\n<\/tr>\n<tr class=\"row-162\">\n\t<td class=\"column-1\">Ford<\/td><td class=\"column-2\">ESJM5P-7w092-AA<\/td><td class=\"column-3\">Pr\u00fcfung technische Sauberkeit<\/td>\n<\/tr>\n<tr class=\"row-163\">\n\t<td class=\"column-1\">Ford<\/td><td class=\"column-2\">ESXS7Q-6L084-AA<\/td><td class=\"column-3\">Specification for acceptable Contamination Levels<\/td>\n<\/tr>\n<tr class=\"row-164\">\n\t<td class=\"column-1\">FTE Automotive<\/td><td class=\"column-2\">201820002<\/td><td class=\"column-3\">Pr\u00fcfungsauftrag<\/td>\n<\/tr>\n<tr class=\"row-165\">\n\t<td class=\"column-1\">FTE Automotive<\/td><td class=\"column-2\">201820009<\/td><td class=\"column-3\">Pr\u00fcfungsauftrag<\/td>\n<\/tr>\n<tr class=\"row-166\">\n\t<td class=\"column-1\">FTE Automotive<\/td><td class=\"column-2\">201820024<\/td><td class=\"column-3\">Pr\u00fcfungsauftrag<\/td>\n<\/tr>\n<tr class=\"row-167\">\n\t<td class=\"column-1\">FTE Automotive<\/td><td class=\"column-2\">FTE-TL042<\/td><td class=\"column-3\">Technische Sauberkeit von Einzelteilen und Baugruppen<\/td>\n<\/tr>\n<tr class=\"row-168\">\n\t<td class=\"column-1\">FTE Automotive<\/td><td class=\"column-2\">FTE-TL042<\/td><td class=\"column-3\">Technische Lieferbedingung<\/td>\n<\/tr>\n<tr class=\"row-169\">\n\t<td class=\"column-1\">FTE Automotive<\/td><td class=\"column-2\">FTE-TL046<\/td><td class=\"column-3\">Restverschmutzung f\u00fcr Ventilgesteuerte Systeme<\/td>\n<\/tr>\n<tr class=\"row-170\">\n\t<td class=\"column-1\">FTE Automotive<\/td><td class=\"column-2\">FTE-TL086<\/td><td class=\"column-3\">Technische Sauberkeit Extraktionsverfahren<\/td>\n<\/tr>\n<tr class=\"row-171\">\n\t<td class=\"column-1\">FTE Automotive<\/td><td class=\"column-2\">S2AG85.023<\/td><td class=\"column-3\">Erstmuster Pr\u00fcfbericht<\/td>\n<\/tr>\n<tr class=\"row-172\">\n\t<td class=\"column-1\">FTE Automotive<\/td><td class=\"column-2\">VAM328<\/td><td class=\"column-3\">Restschmutzanforderung<\/td>\n<\/tr>\n<tr class=\"row-173\">\n\t<td class=\"column-1\">FZ Friedrichshafen<\/td><td class=\"column-2\">4,460,700,101<\/td><td class=\"column-3\">Restschmutzgrenzen<\/td>\n<\/tr>\n<tr class=\"row-174\">\n\t<td class=\"column-1\">Garrett<\/td><td class=\"column-2\">QCI-9310-122<\/td><td class=\"column-3\">Qualitiy Control Instruction<\/td>\n<\/tr>\n<tr class=\"row-175\">\n\t<td class=\"column-1\">Getrag<\/td><td class=\"column-2\">G_904340-2<\/td><td class=\"column-3\">Bestimmung der Technischen Sauberkeit von GETRAG Getriebebauteilen und Baugruppen<\/td>\n<\/tr>\n<tr class=\"row-176\">\n\t<td class=\"column-1\">Getrag<\/td><td class=\"column-2\">G_904340-2<\/td><td class=\"column-3\">Determination of Technical Cleanliness of GETRAG Transmission Components and Modules<\/td>\n<\/tr>\n<tr class=\"row-177\">\n\t<td class=\"column-1\">Getrag<\/td><td class=\"column-2\">GN4340-1<\/td><td class=\"column-3\">Technische Sauberkeit von Getrieben<\/td>\n<\/tr>\n<tr class=\"row-178\">\n\t<td class=\"column-1\">Getrag<\/td><td class=\"column-2\">GN4340-2<\/td><td class=\"column-3\">Technische Sauberkeit von Getrieben<\/td>\n<\/tr>\n<tr class=\"row-179\">\n\t<td class=\"column-1\">GM<\/td><td class=\"column-2\">24282840<\/td><td class=\"column-3\">Engineering Specification<\/td>\n<\/tr>\n<tr class=\"row-180\">\n\t<td class=\"column-1\">GM<\/td><td class=\"column-2\">24282995<\/td><td class=\"column-3\">Engineering Specification<\/td>\n<\/tr>\n<tr class=\"row-181\">\n\t<td class=\"column-1\">GM<\/td><td class=\"column-2\">GME7061<\/td><td class=\"column-3\">Motor- und Getriebekomponenten<\/td>\n<\/tr>\n<tr class=\"row-182\">\n\t<td class=\"column-1\">GM<\/td><td class=\"column-2\">GMI60225<\/td><td class=\"column-3\">Restschmutzermittlung<\/td>\n<\/tr>\n<tr class=\"row-183\">\n\t<td class=\"column-1\">GM<\/td><td class=\"column-2\">GMW14167<\/td><td class=\"column-3\">Transmission and Engine Oil Cooler<\/td>\n<\/tr>\n<tr class=\"row-184\">\n\t<td class=\"column-1\">GM<\/td><td class=\"column-2\">GMW14191<\/td><td class=\"column-3\">Charge Air Cooler<\/td>\n<\/tr>\n<tr class=\"row-185\">\n\t<td class=\"column-1\">GM<\/td><td class=\"column-2\">GMW14193<\/td><td class=\"column-3\">Radiator Product<\/td>\n<\/tr>\n<tr class=\"row-186\">\n\t<td class=\"column-1\">GM<\/td><td class=\"column-2\">GMW16037<\/td><td class=\"column-3\">Powertrain Components<\/td>\n<\/tr>\n<tr class=\"row-187\">\n\t<td class=\"column-1\">GM<\/td><td class=\"column-2\">GMW3191<\/td><td class=\"column-3\">Connector Test and Validation Specification<\/td>\n<\/tr>\n<tr class=\"row-188\">\n\t<td class=\"column-1\">Gnutti Carlo Group<\/td><td class=\"column-2\">GCPT-STD001<\/td><td class=\"column-3\">Cleanliness, Handling, and packaging instruction of purchase parts<\/td>\n<\/tr>\n<tr class=\"row-189\">\n\t<td class=\"column-1\">Hatz<\/td><td class=\"column-2\">95234400<\/td><td class=\"column-3\">Bauteilsauberkeit an Motorkomponenten<\/td>\n<\/tr>\n<tr class=\"row-190\">\n\t<td class=\"column-1\">Hatz<\/td><td class=\"column-2\">H-TL-95182700.9989 D<\/td><td class=\"column-3\">Komponenten f\u00fcr Einspritzsysteme<\/td>\n<\/tr>\n<tr class=\"row-191\">\n\t<td class=\"column-1\">Hella<\/td><td class=\"column-2\">10000622501<\/td><td class=\"column-3\">Cleanliness specification for purchased components<\/td>\n<\/tr>\n<tr class=\"row-192\">\n\t<td class=\"column-1\">Hella<\/td><td class=\"column-2\">DRAFT<\/td><td class=\"column-3\">Hella Requirements for external Analytics <\/td>\n<\/tr>\n<tr class=\"row-193\">\n\t<td class=\"column-1\">Hella <\/td><td class=\"column-2\">HN20302<\/td><td class=\"column-3\">Requirements for External Cleanliness-Measurements<\/td>\n<\/tr>\n<tr class=\"row-194\">\n\t<td class=\"column-1\">Hengst<\/td><td class=\"column-2\">BN3.29<\/td><td class=\"column-3\">Sauberkeitsanforderung<\/td>\n<\/tr>\n<tr class=\"row-195\">\n\t<td class=\"column-1\">Hilite<\/td><td class=\"column-2\">HR4004<\/td><td class=\"column-3\">Standart f\u00fcr Restschmutz und Durchf\u00fchrung einer Restschmutzanalyse<\/td>\n<\/tr>\n<tr class=\"row-196\">\n\t<td class=\"column-1\">Hoerbiger<\/td><td class=\"column-2\">FRM80090001<\/td><td class=\"column-3\">Technical Cleanliness of suppliers products<\/td>\n<\/tr>\n<tr class=\"row-197\">\n\t<td class=\"column-1\">Hoerbiger<\/td><td class=\"column-2\">FRM80090001<\/td><td class=\"column-3\">Technical Cleanliness of suppliers products<\/td>\n<\/tr>\n<tr class=\"row-198\">\n\t<td class=\"column-1\">Hoerbiger<\/td><td class=\"column-2\">PV 45<\/td><td class=\"column-3\">Pr\u00fcfvorschrift \/ Lieferbedingung f\u00fcr die Sauberkeit von Teilen und Ger\u00e4ten<\/td>\n<\/tr>\n<tr class=\"row-199\">\n\t<td class=\"column-1\">Hoerbiger <\/td><td class=\"column-2\">HEX5300AC<\/td><td class=\"column-3\">Festlegung von Restschmutzgrenzwerten<\/td>\n<\/tr>\n<tr class=\"row-200\">\n\t<td class=\"column-1\">Honeywell Turbo Technologies<\/td><td class=\"column-2\">QCI-9310-122 AB<\/td><td class=\"column-3\">Qualitiy Control Instruction<\/td>\n<\/tr>\n<tr class=\"row-201\">\n\t<td class=\"column-1\">Honeywell Turbo Technologies<\/td><td class=\"column-2\">QCI-9310-122 AB<\/td><td class=\"column-3\">Product Cleanliness<\/td>\n<\/tr>\n<tr class=\"row-202\">\n\t<td class=\"column-1\">Honeywell Turbo Technologies<\/td><td class=\"column-2\">QCI-9310-122 AC<\/td><td class=\"column-3\">Qualitiy Control Instruction<\/td>\n<\/tr>\n<tr class=\"row-203\">\n\t<td class=\"column-1\">Honeywell Turbo Technologies<\/td><td class=\"column-2\">QCI-9310-122 S<\/td><td class=\"column-3\">Product Cleanliness<\/td>\n<\/tr>\n<tr class=\"row-204\">\n\t<td class=\"column-1\">Honeywell Turbo Technologies<\/td><td class=\"column-2\">QCI-9310-122.U<\/td><td class=\"column-3\">Qualitiy Control Instruction<\/td>\n<\/tr>\n<tr class=\"row-205\">\n\t<td class=\"column-1\">Honeywell Turbo Technologies<\/td><td class=\"column-2\">QCI-9310-122-BC<\/td><td class=\"column-3\">Product Cleanliness<\/td>\n<\/tr>\n<tr class=\"row-206\">\n\t<td class=\"column-1\">Hydraulik Ring<\/td><td class=\"column-2\">FT-R530.01<\/td><td class=\"column-3\">Pr\u00fcfung auf Restschmutz<\/td>\n<\/tr>\n<tr class=\"row-207\">\n\t<td class=\"column-1\">Hydraulik Ring<\/td><td class=\"column-2\">HR4004<\/td><td class=\"column-3\">Residual Dirt Analysis<\/td>\n<\/tr>\n<tr class=\"row-208\">\n\t<td class=\"column-1\">Hydraulik Ring<\/td><td class=\"column-2\">HR4005 B<\/td><td class=\"column-3\">TecSa<\/td>\n<\/tr>\n<tr class=\"row-209\">\n\t<td class=\"column-1\">Hydraulik Ring<\/td><td class=\"column-2\">HR4005 C<\/td><td class=\"column-3\">TecSa<\/td>\n<\/tr>\n<tr class=\"row-210\">\n\t<td class=\"column-1\">IEST<\/td><td class=\"column-2\">IEST-STD-CC1246E<\/td><td class=\"column-3\">Contaminition Control Division<\/td>\n<\/tr>\n<tr class=\"row-211\">\n\t<td class=\"column-1\">INA<\/td><td class=\"column-2\">N021040<\/td><td class=\"column-3\">Sauberkeitsklassen<\/td>\n<\/tr>\n<tr class=\"row-212\">\n\t<td class=\"column-1\">INA<\/td><td class=\"column-2\">QN5.52<\/td><td class=\"column-3\">Verfahren zur Ermittlung der Sauberkeitsklasse<\/td>\n<\/tr>\n<tr class=\"row-213\">\n\t<td class=\"column-1\">INA<\/td><td class=\"column-2\">ST\/HZA-EMP 15\/0122<\/td><td class=\"column-3\">Untersuchungsbericht<\/td>\n<\/tr>\n<tr class=\"row-214\">\n\t<td class=\"column-1\">ISO  <\/td><td class=\"column-2\">ISO 4407:2002(E)<\/td><td class=\"column-3\">International Standard Hydraulic fluid power<\/td>\n<\/tr>\n<tr class=\"row-215\">\n\t<td class=\"column-1\">ISO DIN<\/td><td class=\"column-2\">DIN 15001<\/td><td class=\"column-3\">DIN EN ISO 15001<\/td>\n<\/tr>\n<tr class=\"row-216\">\n\t<td class=\"column-1\">ISO DIN<\/td><td class=\"column-2\">DIN 4405<\/td><td class=\"column-3\">Hydraulic fluid power-fluid contamination-Determination of particular contamination by the gravimetric method<\/td>\n<\/tr>\n<tr class=\"row-217\">\n\t<td class=\"column-1\">ISO DIN<\/td><td class=\"column-2\">DIN 4406<\/td><td class=\"column-3\">Hydraulic fluid power-fluids-method for coding the level of contamination by solid particles<\/td>\n<\/tr>\n<tr class=\"row-218\">\n\t<td class=\"column-1\">ISO DIN<\/td><td class=\"column-2\">DIN 8949<\/td><td class=\"column-3\">Filtertrockner f\u00fcr K\u00e4ltemittel Pr\u00fcfung<\/td>\n<\/tr>\n<tr class=\"row-219\">\n\t<td class=\"column-1\">ISO DIN<\/td><td class=\"column-2\">DIN 8964-1<\/td><td class=\"column-3\">Kreislaufteile f\u00fcr K\u00e4lteanalgen<\/td>\n<\/tr>\n<tr class=\"row-220\">\n\t<td class=\"column-1\">ISO DIN<\/td><td class=\"column-2\">DIN 8964-2<\/td><td class=\"column-3\">Kreislaufteile f\u00fcr K\u00e4lteanalgen<\/td>\n<\/tr>\n<tr class=\"row-221\">\n\t<td class=\"column-1\">ISO DIN<\/td><td class=\"column-2\">DIN 8964-3<\/td><td class=\"column-3\">Kreislaufteile f\u00fcr K\u00e4lteanalgen<\/td>\n<\/tr>\n<tr class=\"row-222\">\n\t<td class=\"column-1\">ISO DIN<\/td><td class=\"column-2\">ISO 4407<\/td><td class=\"column-3\">Neue ISO-Normen in der Filtertechnik<\/td>\n<\/tr>\n<tr class=\"row-223\">\n\t<td class=\"column-1\">IWIS<\/td><td class=\"column-2\">N380001-F<\/td><td class=\"column-3\">Durchf\u00fchrung von Restschmutzanalysen an Ketten\/Kettentriebkomponenten<\/td>\n<\/tr>\n<tr class=\"row-224\">\n\t<td class=\"column-1\">ixetic<\/td><td class=\"column-2\">S100504 a<\/td><td class=\"column-3\">Sauberkeit von Bauteilen<\/td>\n<\/tr>\n<tr class=\"row-225\">\n\t<td class=\"column-1\">ixetic<\/td><td class=\"column-2\">S100504 d<\/td><td class=\"column-3\">Festlegung von Sauberkeitswerten<\/td>\n<\/tr>\n<tr class=\"row-226\">\n\t<td class=\"column-1\">Jaguar Cars &amp; Land Rover<\/td><td class=\"column-2\">C50064779<\/td><td class=\"column-3\">Breather system<\/td>\n<\/tr>\n<tr class=\"row-227\">\n\t<td class=\"column-1\">Jaguar Cars &amp; Land Rover<\/td><td class=\"column-2\">TPJLR.07.028<\/td><td class=\"column-3\">Measuring Residual Dirt in Automatic Transmission Cooling System Parts<\/td>\n<\/tr>\n<tr class=\"row-228\">\n\t<td class=\"column-1\">Jaguar Cars &amp; Land Rover<\/td><td class=\"column-2\">TPJLR.52.106<\/td><td class=\"column-3\">Measuring Residual Dirt in Automatic Transmission Cooling System Parts<\/td>\n<\/tr>\n<tr class=\"row-229\">\n\t<td class=\"column-1\">JCB<\/td><td class=\"column-2\">9993\/0006<\/td><td class=\"column-3\">Engine Cleanliness four Cylinder<\/td>\n<\/tr>\n<tr class=\"row-230\">\n\t<td class=\"column-1\">John Deere<\/td><td class=\"column-2\">JDS169<\/td><td class=\"column-3\">Cleanliness of Fluids, Parts, Components<\/td>\n<\/tr>\n<tr class=\"row-231\">\n\t<td class=\"column-1\">Joyson Safety Systems<\/td><td class=\"column-2\">N09.052-2<\/td><td class=\"column-3\">Pr\u00fcfung der Sauberkeit von mechanischen Bauteilen f\u00fcr PCB<\/td>\n<\/tr>\n<tr class=\"row-232\">\n\t<td class=\"column-1\">Kayser<\/td><td class=\"column-2\">10115229<\/td><td class=\"column-3\">Ausperleitung<\/td>\n<\/tr>\n<tr class=\"row-233\">\n\t<td class=\"column-1\">Kendrion<\/td><td class=\"column-2\">CPE-GL-001-C<\/td><td class=\"column-3\">Spezifikation technische Sauberkeit<\/td>\n<\/tr>\n<tr class=\"row-234\">\n\t<td class=\"column-1\">Kendrion<\/td><td class=\"column-2\">PCS-RL-SP-01<\/td><td class=\"column-3\">Spezifikation technische Sauberkeit<\/td>\n<\/tr>\n<tr class=\"row-235\">\n\t<td class=\"column-1\">Koni<\/td><td class=\"column-2\">KN-0124<\/td><td class=\"column-3\">Technical Cleanliness Specification<\/td>\n<\/tr>\n<tr class=\"row-236\">\n\t<td class=\"column-1\">Land Rover<\/td><td class=\"column-2\">LRLTM.30.DD:103<\/td><td class=\"column-3\">Methods of Measurement<\/td>\n<\/tr>\n<tr class=\"row-237\">\n\t<td class=\"column-1\">Land Rover<\/td><td class=\"column-2\">LRLTM.30.IC.101<\/td><td class=\"column-3\">Internal Cleanliness of Metal Tubing<\/td>\n<\/tr>\n<tr class=\"row-238\">\n\t<td class=\"column-1\">Land Rover<\/td><td class=\"column-2\">TPJLR.07.028<\/td><td class=\"column-3\">Procedure for Measuring Resuidual Dirt in Automatic Transmission Cooling System Parts<\/td>\n<\/tr>\n<tr class=\"row-239\">\n\t<td class=\"column-1\">Liebherr<\/td><td class=\"column-2\">11347301<\/td><td class=\"column-3\">Technische Liefervorschriften Qualit\u00e4tsrichtlinie<\/td>\n<\/tr>\n<tr class=\"row-240\">\n\t<td class=\"column-1\">Liebherr<\/td><td class=\"column-2\">11481316<\/td><td class=\"column-3\">Sauberkeit von Bauteilen, Betriebsstoffen und Waschmedien<\/td>\n<\/tr>\n<tr class=\"row-241\">\n\t<td class=\"column-1\">Liebherr<\/td><td class=\"column-2\">11481316-001<\/td><td class=\"column-3\">Sauberkeit von Bauteilen, Betriebsstoffen und Waschmedien<\/td>\n<\/tr>\n<tr class=\"row-242\">\n\t<td class=\"column-1\">Liebherr<\/td><td class=\"column-2\">TLV23028<\/td><td class=\"column-3\">Sauberkeit von Bauteilen, Betriebsstoffen und Waschmedien<\/td>\n<\/tr>\n<tr class=\"row-243\">\n\t<td class=\"column-1\">LUK<\/td><td class=\"column-2\">086911103 f<\/td><td class=\"column-3\">Hydraulische Zusammenbauten<\/td>\n<\/tr>\n<tr class=\"row-244\">\n\t<td class=\"column-1\">LUK<\/td><td class=\"column-2\">08691531D a<\/td><td class=\"column-3\">Hydraulische Kupplungselemente<\/td>\n<\/tr>\n<tr class=\"row-245\">\n\t<td class=\"column-1\">LUK<\/td><td class=\"column-2\">QV0020<\/td><td class=\"column-3\">Technische Sauberkeit<\/td>\n<\/tr>\n<tr class=\"row-246\">\n\t<td class=\"column-1\">LUK, INA, FAG<\/td><td class=\"column-2\">S202012-12<\/td><td class=\"column-3\">Bestimmung der Sauberkeitsklasse<\/td>\n<\/tr>\n<tr class=\"row-247\">\n\t<td class=\"column-1\">LUK, INA, FAG<\/td><td class=\"column-2\">S250020<\/td><td class=\"column-3\">Bestimmung des Restschmutzes von fl\u00fcssigen Hilfs-und Betriebsstoffen<\/td>\n<\/tr>\n<tr class=\"row-248\">\n\t<td class=\"column-1\">LUK, INA, FAG<\/td><td class=\"column-2\">S250020<\/td><td class=\"column-3\">fl\u00fcssige Hilfs- und Betriebsstoffe<\/td>\n<\/tr>\n<tr class=\"row-249\">\n\t<td class=\"column-1\">LUK, INA, FAG<\/td><td class=\"column-2\">S252001-1<\/td><td class=\"column-3\">Standard-Sauberkeitsklassen f\u00fcr Produkte und Zukaufteile der Schaeffer Gruppe<\/td>\n<\/tr>\n<tr class=\"row-250\">\n\t<td class=\"column-1\">LUK, INA, FAG<\/td><td class=\"column-2\">S252001-1<\/td><td class=\"column-3\">Standard-Sauberkeitsklassen f\u00fcr Produkte und Zukaufteile der Schaeffer Gruppe<\/td>\n<\/tr>\n<tr class=\"row-251\">\n\t<td class=\"column-1\">LUK, INA, FAG<\/td><td class=\"column-2\">S252001-2<\/td><td class=\"column-3\">Partikelgr\u00f6\u00dfenklassen f\u00fcr Produkte mit erh\u00f6hter Sauberkeitsanforderung<\/td>\n<\/tr>\n<tr class=\"row-252\">\n\t<td class=\"column-1\">LUK, INA, FAG<\/td><td class=\"column-2\">S252011<\/td><td class=\"column-3\">Allgemeine Vorgehensweise zur Sauberkeit<\/td>\n<\/tr>\n<tr class=\"row-253\">\n\t<td class=\"column-1\">LUK, INA, FAG<\/td><td class=\"column-2\">S252012-4<\/td><td class=\"column-3\">Sauberkeitsanalyse<\/td>\n<\/tr>\n<tr class=\"row-254\">\n\t<td class=\"column-1\">LUK, INA, FAG<\/td><td class=\"column-2\">S252012-4<\/td><td class=\"column-3\">Sauberkeitspr\u00fcfung CRS-Standardprodukte<\/td>\n<\/tr>\n<tr class=\"row-255\">\n\t<td class=\"column-1\">LUK, INA, FAG<\/td><td class=\"column-2\">S252012-6<\/td><td class=\"column-3\">Kugelgewindetriebeinheiten und Einzelteile-Sauberkeitsanalyse<\/td>\n<\/tr>\n<tr class=\"row-256\">\n\t<td class=\"column-1\">LUK, INA, FAG<\/td><td class=\"column-2\">S252013-4<\/td><td class=\"column-3\">Vorgehensweise zur Sauberkeitspr\u00fcfung von Ausr\u00fccksystemen<\/td>\n<\/tr>\n<tr class=\"row-257\">\n\t<td class=\"column-1\">LUK, INA, FAG<\/td><td class=\"column-2\">S252013-4<\/td><td class=\"column-3\">Sauberkeit von Ausr\u00fccksystemen<\/td>\n<\/tr>\n<tr class=\"row-258\">\n\t<td class=\"column-1\">Lukas Automotive<\/td><td class=\"column-2\">6-5100 KOOLEMI<\/td><td class=\"column-3\">Technical Specification<\/td>\n<\/tr>\n<tr class=\"row-259\">\n\t<td class=\"column-1\">Magna Powertrain<\/td><td class=\"column-2\">S100504-e<\/td><td class=\"column-3\">Pr\u00fcfung der technischen Sauberkeit<\/td>\n<\/tr>\n<tr class=\"row-260\">\n\t<td class=\"column-1\">Magna Powertrain<\/td><td class=\"column-2\">S40028<\/td><td class=\"column-3\">Pr\u00fcfung der technischen Sauberkeit<\/td>\n<\/tr>\n<tr class=\"row-261\">\n\t<td class=\"column-1\">Magna Powertrain<\/td><td class=\"column-2\">S40029<\/td><td class=\"column-3\">Sauberkeitsklassen<\/td>\n<\/tr>\n<tr class=\"row-262\">\n\t<td class=\"column-1\">Magna Powertrain<\/td><td class=\"column-2\">TETS0008<\/td><td class=\"column-3\">Oil Pumps and Lubrication Systems Components<\/td>\n<\/tr>\n<tr class=\"row-263\">\n\t<td class=\"column-1\">Magnet Schulz<\/td><td class=\"column-2\">W0181-00<\/td><td class=\"column-3\">Index a<\/td>\n<\/tr>\n<tr class=\"row-264\">\n\t<td class=\"column-1\">Magnet Schulz<\/td><td class=\"column-2\">W0181-00<\/td><td class=\"column-3\">Index d<\/td>\n<\/tr>\n<tr class=\"row-265\">\n\t<td class=\"column-1\">Magnet Schulz<\/td><td class=\"column-2\">W0181-00<\/td><td class=\"column-3\">Index e<\/td>\n<\/tr>\n<tr class=\"row-266\">\n\t<td class=\"column-1\">Magnet Schulz<\/td><td class=\"column-2\">W0181-00<\/td><td class=\"column-3\">Index f<\/td>\n<\/tr>\n<tr class=\"row-267\">\n\t<td class=\"column-1\">Magnet Schulz<\/td><td class=\"column-2\">W0181-00<\/td><td class=\"column-3\">Index i<\/td>\n<\/tr>\n<tr class=\"row-268\">\n\t<td class=\"column-1\">Magnet Schulz<\/td><td class=\"column-2\">W0181-00<\/td><td class=\"column-3\">Index h<\/td>\n<\/tr>\n<tr class=\"row-269\">\n\t<td class=\"column-1\">Magneti Marelli<\/td><td class=\"column-2\">00065824<\/td><td class=\"column-3\">Throttle body cleaning test procedure<\/td>\n<\/tr>\n<tr class=\"row-270\">\n\t<td class=\"column-1\">Magneti Marelli<\/td><td class=\"column-2\">00078523<\/td><td class=\"column-3\">Specifications for verifying that machanical parts are clean<\/td>\n<\/tr>\n<tr class=\"row-271\">\n\t<td class=\"column-1\">Magneti Marelli<\/td><td class=\"column-2\">00090380<\/td><td class=\"column-3\">Testing Petrol Pump Cleanness<\/td>\n<\/tr>\n<tr class=\"row-272\">\n\t<td class=\"column-1\">Mahle<\/td><td class=\"column-2\">[VE]AR.07424<\/td><td class=\"column-3\">Technical Cleanliness of Individual Components, General Limit Values<\/td>\n<\/tr>\n<tr class=\"row-273\">\n\t<td class=\"column-1\">Mahle<\/td><td class=\"column-2\">01009766 V3<\/td><td class=\"column-3\">Anaysesp\u00fclvorschrift Daimler M274 und M276 iLLK<\/td>\n<\/tr>\n<tr class=\"row-274\">\n\t<td class=\"column-1\">Mahle<\/td><td class=\"column-2\">GN AR.01024<\/td><td class=\"column-3\">Anforderungen an die Reinigungsqualit\u00e4t von internen und externen Zukaufteilen f\u00fcr die Aluminium-L\u00f6tung, Alumini-um Gussteilen und dem Aluminium-Schwei\u00dfprozess<\/td>\n<\/tr>\n<tr class=\"row-275\">\n\t<td class=\"column-1\">Mahle<\/td><td class=\"column-2\">GN AR.01024<\/td><td class=\"column-3\">Manufacturing Lubricant and degreasing methods for the Pro-duction of Components and Assemblies within MAHLE BU3 and at External Suppliers<\/td>\n<\/tr>\n<tr class=\"row-276\">\n\t<td class=\"column-1\">Mahle<\/td><td class=\"column-2\">M3576-1<\/td><td class=\"column-3\">Motorbauteile mit besonderen Anforderungen an die Technische Sauberkeit<\/td>\n<\/tr>\n<tr class=\"row-277\">\n\t<td class=\"column-1\">Mahle<\/td><td class=\"column-2\">PN AR.01494<\/td><td class=\"column-3\">Pr\u00fcfnorm K\u00fchlmittelseitige Flussmittelreste in Aluminiumw\u00e4remetauschern<\/td>\n<\/tr>\n<tr class=\"row-278\">\n\t<td class=\"column-1\">Mahle<\/td><td class=\"column-2\">PN AR07424-05<\/td><td class=\"column-3\">Technische Sauberkeit von Einzelteilen f\u00fcr Indirekten Kodensator<\/td>\n<\/tr>\n<tr class=\"row-279\">\n\t<td class=\"column-1\">Mahle<\/td><td class=\"column-2\"><\/td><td class=\"column-3\">Analyse Technische Sauberkeit BMW 35up iCond<\/td>\n<\/tr>\n<tr class=\"row-280\">\n\t<td class=\"column-1\">Mahle <\/td><td class=\"column-2\">AR.07423<\/td><td class=\"column-3\">Techniche Sauberkeit von Einzelzeilen f\u00fcr Komponenten in K\u00fchlmittelkreisl\u00e4ufen<\/td>\n<\/tr>\n<tr class=\"row-281\">\n\t<td class=\"column-1\">Mahle <\/td><td class=\"column-2\">AR.AR06956<\/td><td class=\"column-3\">Technische Sauberkeit von Einzelteilen, allgemeine Grenzwerte<\/td>\n<\/tr>\n<tr class=\"row-282\">\n\t<td class=\"column-1\">Mahle <\/td><td class=\"column-2\">PmL.0100<\/td><td class=\"column-3\">Lastenheft \/ Specification Technische Sauberkeit Verdampfer Einzelteile nach DAG Vorgaben<\/td>\n<\/tr>\n<tr class=\"row-283\">\n\t<td class=\"column-1\">Mahle <\/td><td class=\"column-2\">PN AR 01236<\/td><td class=\"column-3\">Determing the Lubricant on Metallic Material Surfaces<\/td>\n<\/tr>\n<tr class=\"row-284\">\n\t<td class=\"column-1\">Mahle <\/td><td class=\"column-2\">PN AR.0742<\/td><td class=\"column-3\">Technical Cleanliness of Single Parts for Components in the Refrigerant Circuit<\/td>\n<\/tr>\n<tr class=\"row-285\">\n\t<td class=\"column-1\">Mahle <\/td><td class=\"column-2\">PN AR.07423-01<\/td><td class=\"column-3\">Techniche Sauberkeit von Einzelzeilen f\u00fcr gel\u00f6tete Heizk\u00f6rper<\/td>\n<\/tr>\n<tr class=\"row-286\">\n\t<td class=\"column-1\">Mahle <\/td><td class=\"column-2\">PN AR.07424-06<\/td><td class=\"column-3\">Technische Sauberkeit von Einzelteilen f\u00fcr Chiller<\/td>\n<\/tr>\n<tr class=\"row-287\">\n\t<td class=\"column-1\">Mahle <\/td><td class=\"column-2\">PN AR.07424-06<\/td><td class=\"column-3\">Technical Cleanliness of the Single Parts for Chiller<\/td>\n<\/tr>\n<tr class=\"row-288\">\n\t<td class=\"column-1\">Mahle <\/td><td class=\"column-2\">PN AR.07424-06<\/td><td class=\"column-3\">Technical Cleanliness of the Single Parts for Chiller<\/td>\n<\/tr>\n<tr class=\"row-289\">\n\t<td class=\"column-1\">Mahle <\/td><td class=\"column-2\">SN AR.08177 : 2022-02<\/td><td class=\"column-3\">Evaporator CAB\u00ae-brazed Evaporator VOLVO SPA 2 rear<\/td>\n<\/tr>\n<tr class=\"row-290\">\n\t<td class=\"column-1\">MAN<\/td><td class=\"column-2\">11347301<\/td><td class=\"column-3\">Sauberkeit von Bauteilen, Betriebsstoffen und Waschmedien<\/td>\n<\/tr>\n<tr class=\"row-291\">\n\t<td class=\"column-1\">MAN<\/td><td class=\"column-2\">M3360<\/td><td class=\"column-3\">Bauteile mit besonderen Anforderungen an die Sauberkeit<\/td>\n<\/tr>\n<tr class=\"row-292\">\n\t<td class=\"column-1\">MAN<\/td><td class=\"column-2\">M-3576-1<\/td><td class=\"column-3\">Besondere Anforderung an die Technische Sauberkeit<\/td>\n<\/tr>\n<tr class=\"row-293\">\n\t<td class=\"column-1\">MDS Abele<\/td><td class=\"column-2\"><\/td><td class=\"column-3\">Metalldruck- und Spritzguss<\/td>\n<\/tr>\n<tr class=\"row-294\">\n\t<td class=\"column-1\">Mercedes Benz<\/td><td class=\"column-2\">YAP1651814<\/td><td class=\"column-3\">Ausfg. Vorsch Hadraulik Federungssystem<\/td>\n<\/tr>\n<tr class=\"row-295\">\n\t<td class=\"column-1\">MG Rover Group<\/td><td class=\"column-2\">21CC01C<\/td><td class=\"column-3\">Cleanliness of Powertrain Components<\/td>\n<\/tr>\n<tr class=\"row-296\">\n\t<td class=\"column-1\">MM Sachs<\/td><td class=\"column-2\">WN 70\/13<\/td><td class=\"column-3\">Ermitlung von Schmutzr\u00fcckst\u00e4nden an Einzelteilen<\/td>\n<\/tr>\n<tr class=\"row-297\">\n\t<td class=\"column-1\">MTU Friedrichshafen<\/td><td class=\"column-2\">MMN370<\/td><td class=\"column-3\">Reinheitspr\u00fcfung von Konstruktionsteilen<\/td>\n<\/tr>\n<tr class=\"row-298\">\n\t<td class=\"column-1\">MTU Friedrichshafen<\/td><td class=\"column-2\">MTL5034<\/td><td class=\"column-3\">Spaltfilter f\u00fcr Motor- und Getriebeschmier\u00f6l<\/td>\n<\/tr>\n<tr class=\"row-299\">\n\t<td class=\"column-1\">MTU Friedrichshafen<\/td><td class=\"column-2\">MTN5253<\/td><td class=\"column-3\">Techn. Sauberkeit von Bauteilen mit h\u00f6heren Anforderungen<\/td>\n<\/tr>\n<tr class=\"row-300\">\n\t<td class=\"column-1\">MTU Friedrichshafen<\/td><td class=\"column-2\">MTN5253-1<\/td><td class=\"column-3\">Technische Sauberkeit von Bauteilen<\/td>\n<\/tr>\n<tr class=\"row-301\">\n\t<td class=\"column-1\">MTU Friedrichshafen<\/td><td class=\"column-2\">MTN5253-2<\/td><td class=\"column-3\">Technische Sauberkeit von Bauteilen <\/td>\n<\/tr>\n<tr class=\"row-302\">\n\t<td class=\"column-1\">MTU Friedrichshafen<\/td><td class=\"column-2\">MTV5067<\/td><td class=\"column-3\">Bestimmung der Restschmutzmenge<\/td>\n<\/tr>\n<tr class=\"row-303\">\n\t<td class=\"column-1\">M\u00fcller-Weingarten<\/td><td class=\"column-2\"><\/td><td class=\"column-3\">Untersuchungsablauf Schmiedepresse <\/td>\n<\/tr>\n<tr class=\"row-304\">\n\t<td class=\"column-1\">MWM Brasil<\/td><td class=\"column-2\">TR305<\/td><td class=\"column-3\">Engine Components Level of Cleanliness<\/td>\n<\/tr>\n<tr class=\"row-305\">\n\t<td class=\"column-1\">NACCO<\/td><td class=\"column-2\">K146<\/td><td class=\"column-3\">METHOD FOR GRAVIMETRIC DETERMINATION OF PART CLEANLINESS<\/td>\n<\/tr>\n<tr class=\"row-306\">\n\t<td class=\"column-1\">Nidec<\/td><td class=\"column-2\">NGPM-S-011<\/td><td class=\"column-3\">Anforderungen an die Technische Sauberkein<\/td>\n<\/tr>\n<tr class=\"row-307\">\n\t<td class=\"column-1\">Nova Werke AG<\/td><td class=\"column-2\">BL876<\/td><td class=\"column-3\">Brennstoffleitung<\/td>\n<\/tr>\n<tr class=\"row-308\">\n\t<td class=\"column-1\">Oskar Schwenk<\/td><td class=\"column-2\">PV<\/td><td class=\"column-3\">Druckfeder<\/td>\n<\/tr>\n<tr class=\"row-309\">\n\t<td class=\"column-1\">Paccar<\/td><td class=\"column-2\">CPP0331<\/td><td class=\"column-3\">Cleanliness of Engines and Engine-Related Parts<\/td>\n<\/tr>\n<tr class=\"row-310\">\n\t<td class=\"column-1\">Paccar<\/td><td class=\"column-2\">CPP0331<\/td><td class=\"column-3\">Cleanliness of Engines and Engine-Related Parts<\/td>\n<\/tr>\n<tr class=\"row-311\">\n\t<td class=\"column-1\">Perkins<\/td><td class=\"column-2\">TD292<\/td><td class=\"column-3\">Premium Cleanliness of Components<\/td>\n<\/tr>\n<tr class=\"row-312\">\n\t<td class=\"column-1\">pharmacpoeia<\/td><td class=\"column-2\"><\/td><td class=\"column-3\">Particular matter in injections<\/td>\n<\/tr>\n<tr class=\"row-313\">\n\t<td class=\"column-1\">Pierburg<\/td><td class=\"column-2\">D800327000<\/td><td class=\"column-3\">Restschmutzbestimmung bei fertigbearbeiteten Teilen<\/td>\n<\/tr>\n<tr class=\"row-314\">\n\t<td class=\"column-1\">Pierburg<\/td><td class=\"column-2\">D800838000<\/td><td class=\"column-3\">Liefervorschrift f\u00fcr AGR-Ventile<\/td>\n<\/tr>\n<tr class=\"row-315\">\n\t<td class=\"column-1\">Pierburg<\/td><td class=\"column-2\">D-800838000<\/td><td class=\"column-3\">Technische Lieferantenvorschrift f\u00fcr Komponenten f\u00fcr AGR Ventile<\/td>\n<\/tr>\n<tr class=\"row-316\">\n\t<td class=\"column-1\">Pierburg<\/td><td class=\"column-2\">D800838010<\/td><td class=\"column-3\">Liefervorschrift f\u00fcr AGR-Ventile<\/td>\n<\/tr>\n<tr class=\"row-317\">\n\t<td class=\"column-1\">Pierburg<\/td><td class=\"column-2\">D-800838020<\/td><td class=\"column-3\">Technical Delivery Specification - General Requirements<\/td>\n<\/tr>\n<tr class=\"row-318\">\n\t<td class=\"column-1\">Pierburg<\/td><td class=\"column-2\">D-802757000<\/td><td class=\"column-3\">Applikationsrichtlinie<\/td>\n<\/tr>\n<tr class=\"row-319\">\n\t<td class=\"column-1\">Pierburg<\/td><td class=\"column-2\">D802806000<\/td><td class=\"column-3\">Technische Lieferbedingungen zur Sauberkeit von Bauteilen<\/td>\n<\/tr>\n<tr class=\"row-320\">\n\t<td class=\"column-1\">Pierburg<\/td><td class=\"column-2\">PN 02.035<\/td><td class=\"column-3\">Part Cleanliness Classification<\/td>\n<\/tr>\n<tr class=\"row-321\">\n\t<td class=\"column-1\">Pierburg<\/td><td class=\"column-2\">PN02.035<\/td><td class=\"column-3\">Klassifizierung Technische Sauberkeit<\/td>\n<\/tr>\n<tr class=\"row-322\">\n\t<td class=\"column-1\">Pierburg<\/td><td class=\"column-2\">PN-PG 02.035-1<\/td><td class=\"column-3\">TecSa Endprodukte und Komponenten<\/td>\n<\/tr>\n<tr class=\"row-323\">\n\t<td class=\"column-1\">Pierburg<\/td><td class=\"column-2\">PN-PG 02.035-2<\/td><td class=\"column-3\">TecSa Endprodukte und Komponenten<\/td>\n<\/tr>\n<tr class=\"row-324\">\n\t<td class=\"column-1\">Polaris<\/td><td class=\"column-2\">ENG-PRO-04-001<\/td><td class=\"column-3\">Powertrain Engine Component Cleanliness<\/td>\n<\/tr>\n<tr class=\"row-325\">\n\t<td class=\"column-1\">Pollmann<\/td><td class=\"column-2\">TST N00202.22<\/td><td class=\"column-3\">Cleanliness<\/td>\n<\/tr>\n<tr class=\"row-326\">\n\t<td class=\"column-1\">Porsche<\/td><td class=\"column-2\">991 GT3<\/td><td class=\"column-3\">Restscgmutzvorgaben<\/td>\n<\/tr>\n<tr class=\"row-327\">\n\t<td class=\"column-1\">Porsche<\/td><td class=\"column-2\">PN 132<\/td><td class=\"column-3\">Sauberkeit von Bauteilen und Ladungstr\u00e4gern <\/td>\n<\/tr>\n<tr class=\"row-328\">\n\t<td class=\"column-1\">Porsche<\/td><td class=\"column-2\">PPV 4070<\/td><td class=\"column-3\">Pr\u00fcfung von Leitungen, Schl\u00e4uche, Rohre<\/td>\n<\/tr>\n<tr class=\"row-329\">\n\t<td class=\"column-1\">Porsche<\/td><td class=\"column-2\">PTL 14045<\/td><td class=\"column-3\">Zul\u00e4ssige Restscgmutz in \u00f6lf\u00fchrenden Bauteilen<\/td>\n<\/tr>\n<tr class=\"row-330\">\n\t<td class=\"column-1\">Porsche<\/td><td class=\"column-2\">PTL 14054<\/td><td class=\"column-3\">technische Lieferbedingungen Schl\u00e4uche aus Gummi<\/td>\n<\/tr>\n<tr class=\"row-331\">\n\t<td class=\"column-1\">Porsche<\/td><td class=\"column-2\">PTL14045<\/td><td class=\"column-3\">\u00f6lf\u00fchrende Bauteile<\/td>\n<\/tr>\n<tr class=\"row-332\">\n\t<td class=\"column-1\">Porsche<\/td><td class=\"column-2\">PTL14050<\/td><td class=\"column-3\">\u00d6l- und Kraftstoffleitungen<\/td>\n<\/tr>\n<tr class=\"row-333\">\n\t<td class=\"column-1\">Prefag<\/td><td class=\"column-2\">PN2017-02<\/td><td class=\"column-3\">Restverschmutzung<\/td>\n<\/tr>\n<tr class=\"row-334\">\n\t<td class=\"column-1\">Prefag<\/td><td class=\"column-2\">PN2017-02<\/td><td class=\"column-3\">Restverschmutzung<\/td>\n<\/tr>\n<tr class=\"row-335\">\n\t<td class=\"column-1\">PSA Peugeot Citroen<\/td><td class=\"column-2\">9636305399<\/td><td class=\"column-3\">Cleanliness specifications: high pressure gasoline pump<\/td>\n<\/tr>\n<tr class=\"row-336\">\n\t<td class=\"column-1\">PSA Peugeot Citroen<\/td><td class=\"column-2\">9643839799<\/td><td class=\"column-3\">S.T.S. of suspension-steering hydraulic unit cleanliness<\/td>\n<\/tr>\n<tr class=\"row-337\">\n\t<td class=\"column-1\">PSA Peugeot Citroen<\/td><td class=\"column-2\">B32 6215<\/td><td class=\"column-3\">COOLING AND HEATING RADIATORS INTERNAL CLEANLINESS<\/td>\n<\/tr>\n<tr class=\"row-338\">\n\t<td class=\"column-1\">PSA Peugeot Citroen<\/td><td class=\"column-2\">B320400<\/td><td class=\"column-3\">Circuits moteur proprete moteurs tous types multi-circuits<\/td>\n<\/tr>\n<tr class=\"row-339\">\n\t<td class=\"column-1\">PSA Peugeot Citroen<\/td><td class=\"column-2\">D705429<\/td><td class=\"column-3\">Mesures de la pollution particulaire globale des pieces automobile<\/td>\n<\/tr>\n<tr class=\"row-340\">\n\t<td class=\"column-1\">PSA Peugeot Citroen<\/td><td class=\"column-2\">D705432<\/td><td class=\"column-3\">Mesures de la pollution particulaire globale des pieces automobile<\/td>\n<\/tr>\n<tr class=\"row-341\">\n\t<td class=\"column-1\">PSA Peugeot Citroen<\/td><td class=\"column-2\">D795453<\/td><td class=\"column-3\">Mesures de la pollution particulaire des pieces automobile <\/td>\n<\/tr>\n<tr class=\"row-342\">\n\t<td class=\"column-1\">Rausch &amp; Pausch<\/td><td class=\"column-2\">PV 16420<\/td><td class=\"column-3\">Anforderung an die Reinheit von Einzelteilen und Baugruppen<\/td>\n<\/tr>\n<tr class=\"row-343\">\n\t<td class=\"column-1\">Renault<\/td><td class=\"column-2\">34-00-035\/--B<\/td><td class=\"column-3\">MANUAL GEAR BOXES - CLEANLINESS<\/td>\n<\/tr>\n<tr class=\"row-344\">\n\t<td class=\"column-1\">Renault<\/td><td class=\"column-2\">34-07-005\/--B<\/td><td class=\"column-3\">Engine Oil Ciruit Cleanliness<\/td>\n<\/tr>\n<tr class=\"row-345\">\n\t<td class=\"column-1\">Renault<\/td><td class=\"column-2\">34-07-005\/--E<\/td><td class=\"column-3\">Cleanliness if the oil system<\/td>\n<\/tr>\n<tr class=\"row-346\">\n\t<td class=\"column-1\">Renault<\/td><td class=\"column-2\">34-07-005\/--E<\/td><td class=\"column-3\">Cahier des charges<\/td>\n<\/tr>\n<tr class=\"row-347\">\n\t<td class=\"column-1\">Renault<\/td><td class=\"column-2\">34-07-006\/--G<\/td><td class=\"column-3\">Specifications<\/td>\n<\/tr>\n<tr class=\"row-348\">\n\t<td class=\"column-1\">Renault<\/td><td class=\"column-2\">34-07-012\/--B<\/td><td class=\"column-3\">Producht Specifications<\/td>\n<\/tr>\n<tr class=\"row-349\">\n\t<td class=\"column-1\">Renault<\/td><td class=\"column-2\">34-07-012\/--B\/--C\/--E<\/td><td class=\"column-3\">Cleanliness of Cooling Systems<\/td>\n<\/tr>\n<tr class=\"row-350\">\n\t<td class=\"column-1\">Renault<\/td><td class=\"column-2\">34-07-012\/--C<\/td><td class=\"column-3\">Product Specifications<\/td>\n<\/tr>\n<tr class=\"row-351\">\n\t<td class=\"column-1\">Renault<\/td><td class=\"column-2\">34-07-012\/--E<\/td><td class=\"column-3\">Cahier des charges<\/td>\n<\/tr>\n<tr class=\"row-352\">\n\t<td class=\"column-1\">Renault<\/td><td class=\"column-2\">34-07-024\/--B<\/td><td class=\"column-3\">Cleanliness of Refrigerant Liquid -Circuits<\/td>\n<\/tr>\n<tr class=\"row-353\">\n\t<td class=\"column-1\">Renault<\/td><td class=\"column-2\">34-07-024\/--B<\/td><td class=\"column-3\">Product Specifications<\/td>\n<\/tr>\n<tr class=\"row-354\">\n\t<td class=\"column-1\">Renault<\/td><td class=\"column-2\">34-07-024\/--B<\/td><td class=\"column-3\">Product Specifications<\/td>\n<\/tr>\n<tr class=\"row-355\">\n\t<td class=\"column-1\">Renault<\/td><td class=\"column-2\">34-07-025\/--E\/--F\/--G\/--H<\/td><td class=\"column-3\">Air Curcuit Cleanliness<\/td>\n<\/tr>\n<tr class=\"row-356\">\n\t<td class=\"column-1\">Renault<\/td><td class=\"column-2\">34-07-025\/--F<\/td><td class=\"column-3\">Cahier des charges<\/td>\n<\/tr>\n<tr class=\"row-357\">\n\t<td class=\"column-1\">Renault<\/td><td class=\"column-2\">34-07-025\/--G<\/td><td class=\"column-3\">Product Specifications<\/td>\n<\/tr>\n<tr class=\"row-358\">\n\t<td class=\"column-1\">Renault<\/td><td class=\"column-2\">34-07-025\/--H<\/td><td class=\"column-3\">Cahier des charges<\/td>\n<\/tr>\n<tr class=\"row-359\">\n\t<td class=\"column-1\">Renault<\/td><td class=\"column-2\">35-00-035\/--B<\/td><td class=\"column-3\">Product Specifications<\/td>\n<\/tr>\n<tr class=\"row-360\">\n\t<td class=\"column-1\">Renault<\/td><td class=\"column-2\">35-00-035\/--B<\/td><td class=\"column-3\">Boites Vitesses Manuells-Proprete<\/td>\n<\/tr>\n<tr class=\"row-361\">\n\t<td class=\"column-1\">Renault<\/td><td class=\"column-2\">37-00-024\/--A<\/td><td class=\"column-3\">Test Procedure<\/td>\n<\/tr>\n<tr class=\"row-362\">\n\t<td class=\"column-1\">Renault<\/td><td class=\"column-2\">39-00-005\/--B<\/td><td class=\"column-3\">Procedure D'Essai<\/td>\n<\/tr>\n<tr class=\"row-363\">\n\t<td class=\"column-1\">Renault<\/td><td class=\"column-2\">BMIR-M0056-2005-0041 2.0<\/td><td class=\"column-3\">Cahier des charges<\/td>\n<\/tr>\n<tr class=\"row-364\">\n\t<td class=\"column-1\">Renault\/Nissan<\/td><td class=\"column-2\">RNDS-C-20149 EN<\/td><td class=\"column-3\">Paart\/module generic specifications<\/td>\n<\/tr>\n<tr class=\"row-365\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">13201335<\/td><td class=\"column-3\">Technische Sauberkeit Befestigungsblech<\/td>\n<\/tr>\n<tr class=\"row-366\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">1 279 916 015<\/td><td class=\"column-3\">Anlage V02 zur Pr\u00fcfvoschrift<\/td>\n<\/tr>\n<tr class=\"row-367\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">1 279 925 760<\/td><td class=\"column-3\">Pr\u00fcfvorschrift Technische Sauberkeit Teile und Kompinenten von externen Lieferanten<\/td>\n<\/tr>\n<tr class=\"row-368\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">1582990125<\/td><td class=\"column-3\">\u00dcberpr\u00fcfung auf Verunreinugungen<\/td>\n<\/tr>\n<tr class=\"row-369\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">1689918591<\/td><td class=\"column-3\">Sauberkeitsanforderung an Fremdbezugsteile f\u00fcr Komponenten<\/td>\n<\/tr>\n<tr class=\"row-370\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">1689918591<\/td><td class=\"column-3\">Sauberkeitsanforderung Fremdbezugsteile<\/td>\n<\/tr>\n<tr class=\"row-371\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">2439918347<\/td><td class=\"column-3\">Restschmutzbestimmung im Kraftstoffverteilerst\u00fcck<\/td>\n<\/tr>\n<tr class=\"row-372\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">4497016443<\/td><td class=\"column-3\">Verbot und Deklaration von Inhaltsstoffen<\/td>\n<\/tr>\n<tr class=\"row-373\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">0042S00542.BV<\/td><td class=\"column-3\">Technical Cleanliness of Supplier Parts for 48V Performance Batteries<\/td>\n<\/tr>\n<tr class=\"row-374\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">0131Y01286<\/td><td class=\"column-3\">Technische Sauberkeit Hlter <\/td>\n<\/tr>\n<tr class=\"row-375\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">0132Y00274<\/td><td class=\"column-3\">Technische Sauberkeit<\/td>\n<\/tr>\n<tr class=\"row-376\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">0132Y00407<\/td><td class=\"column-3\">Technische Sauberkeit iBooster<\/td>\n<\/tr>\n<tr class=\"row-377\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">0132Y00424<\/td><td class=\"column-3\">Technische Sauberkeit<\/td>\n<\/tr>\n<tr class=\"row-378\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">0132Y012010<\/td><td class=\"column-3\">Teschnische Sauberkeit, allgemeiner Teil<\/td>\n<\/tr>\n<tr class=\"row-379\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">0132Y01210<\/td><td class=\"column-3\">Testspezifikation allgemeiner Teil<\/td>\n<\/tr>\n<tr class=\"row-380\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">0132Y01377<\/td><td class=\"column-3\">Teschnische Sauberkeit Abschlussdeckel<\/td>\n<\/tr>\n<tr class=\"row-381\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">0140Y03947<\/td><td class=\"column-3\">Test specification Pr\u00fcfvorschrift<\/td>\n<\/tr>\n<tr class=\"row-382\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">0140Y03947<\/td><td class=\"column-3\">Technische Sauberkeit Pumpengeh\u00e4use<\/td>\n<\/tr>\n<tr class=\"row-383\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">0196.Y00.404<\/td><td class=\"column-3\">Anlage zur Pr\u00fcfvorschrift<\/td>\n<\/tr>\n<tr class=\"row-384\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">0196.Y00.541<\/td><td class=\"column-3\">Technische Sauberkeit<\/td>\n<\/tr>\n<tr class=\"row-385\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">0196Y00282<\/td><td class=\"column-3\">Fertigungshinweis<\/td>\n<\/tr>\n<tr class=\"row-386\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">0196Y01218<\/td><td class=\"column-3\">Pr\u00fcfvorschrift<\/td>\n<\/tr>\n<tr class=\"row-387\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">0203SS5351g<\/td><td class=\"column-3\">Bestellvorschrift Artikel\/ Artikelgruppe<\/td>\n<\/tr>\n<tr class=\"row-388\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">0204Y21344<\/td><td class=\"column-3\">Foreign Material - Maximum Allowance<\/td>\n<\/tr>\n<tr class=\"row-389\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">0204Y21428<\/td><td class=\"column-3\">Foreign Material - Maximum Allowance<\/td>\n<\/tr>\n<tr class=\"row-390\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">0261P04326-02<\/td><td class=\"column-3\">HDP6 Bestellvorschrift Sauberkeitsanforderung<\/td>\n<\/tr>\n<tr class=\"row-391\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">0265R40136<\/td><td class=\"column-3\">Sauberkeitsspezifikation IPB<\/td>\n<\/tr>\n<tr class=\"row-392\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">0265Z4DV2122<\/td><td class=\"column-3\">Sauberkeitsspezifikation IPB<\/td>\n<\/tr>\n<tr class=\"row-393\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">0442P00008<\/td><td class=\"column-3\">Technische Sauberkeit<\/td>\n<\/tr>\n<tr class=\"row-394\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">0442S00168.BV<\/td><td class=\"column-3\">Technical Cleanliness Relay for LV (48V) Battery Systems<\/td>\n<\/tr>\n<tr class=\"row-395\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">0444Y039YS-01<\/td><td class=\"column-3\">Test specification <\/td>\n<\/tr>\n<tr class=\"row-396\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">0445P20246<\/td><td class=\"column-3\">Common Rail<\/td>\n<\/tr>\n<tr class=\"row-397\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">0445P20246<\/td><td class=\"column-3\">Pr\u00fcfvorschrift Common Rail<\/td>\n<\/tr>\n<tr class=\"row-398\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">0445P42013<\/td><td class=\"column-3\">Verfahrenzur Bestimmung der technischen Sauberkeit der CP4i-Hochdruckpumpe<\/td>\n<\/tr>\n<tr class=\"row-399\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">0445P75260<\/td><td class=\"column-3\">Pr\u00fcfvorschrift technische Sauberkeit eSV<\/td>\n<\/tr>\n<tr class=\"row-400\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">0446Y00898<\/td><td class=\"column-3\">Allgemeine Pr\u00fcfvorschrift Common Rail<\/td>\n<\/tr>\n<tr class=\"row-401\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">0580P00167<\/td><td class=\"column-3\">Order directive<\/td>\n<\/tr>\n<tr class=\"row-402\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">1 270 R0M 009 (EBV)<\/td><td class=\"column-3\">Anlage zu Rahmen Bestellvorschrift<\/td>\n<\/tr>\n<tr class=\"row-403\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">1469C18148<\/td><td class=\"column-3\">Pr\u00fcfwerteblatt Bestiimung der technischen Sauberkeit von Hochdruckpumpe<\/td>\n<\/tr>\n<tr class=\"row-404\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">1469D18165<\/td><td class=\"column-3\">Pr\u00fcfmethodenblatt f\u00fcr die Sauberkeitsanalyse der Steckh\u00fclse des DMV25<\/td>\n<\/tr>\n<tr class=\"row-405\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">1928B00007<\/td><td class=\"column-3\">Bestellvorschrift<\/td>\n<\/tr>\n<tr class=\"row-406\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">1928B00108<\/td><td class=\"column-3\">Sauberkeit<\/td>\n<\/tr>\n<tr class=\"row-407\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">AS00002479<\/td><td class=\"column-3\">Sauberkeit von ZFLS-Produkten; Pr\u00fcfvorschrift<\/td>\n<\/tr>\n<tr class=\"row-408\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">BhP\/PVA 001<\/td><td class=\"column-3\">Abdampfr\u00fcckstand an Teilen<\/td>\n<\/tr>\n<tr class=\"row-409\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">BhP\/PVA 261<\/td><td class=\"column-3\">Supplier Cleanliness Testing<\/td>\n<\/tr>\n<tr class=\"row-410\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">BhP\/PVA 261<\/td><td class=\"column-3\">Test Instruction Supplier Cleanliness Testing<\/td>\n<\/tr>\n<tr class=\"row-411\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">BPV 8600 HM0030<\/td><td class=\"column-3\">Stanz-,Zieh- und Biegeteile punched, drawn bent parts<\/td>\n<\/tr>\n<tr class=\"row-412\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">BV_48 1383<\/td><td class=\"column-3\">Bestellvorschrift Artikel\/ Artikelgruppe<\/td>\n<\/tr>\n<tr class=\"row-413\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">F00BU00211<\/td><td class=\"column-3\">Sauberkeits-Pr\u00fcfmethodenblatt f\u00fcr Common Rail Injekor LE<\/td>\n<\/tr>\n<tr class=\"row-414\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">F00BU00211<\/td><td class=\"column-3\">Common Rail<\/td>\n<\/tr>\n<tr class=\"row-415\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">F00BU00246<\/td><td class=\"column-3\">Vorbehandlung Gewindeteile<\/td>\n<\/tr>\n<tr class=\"row-416\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">F00BU00246<\/td><td class=\"column-3\">Prozessvorschrift f\u00fcr Gewindeteile<\/td>\n<\/tr>\n<tr class=\"row-417\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">F00BU00292<\/td><td class=\"column-3\">Cleanliness Requirements Valve Flange<\/td>\n<\/tr>\n<tr class=\"row-418\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">F00BU00293<\/td><td class=\"column-3\">Cleanliness Requirements Valve Cover<\/td>\n<\/tr>\n<tr class=\"row-419\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">F00BU00294<\/td><td class=\"column-3\">Cleanliness Requirements Valve Ring<\/td>\n<\/tr>\n<tr class=\"row-420\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">F028Z78608<\/td><td class=\"column-3\">Technische Sauberkeit f\u00fcr Zulieferteile<\/td>\n<\/tr>\n<tr class=\"row-421\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">F02NP00355-01<\/td><td class=\"column-3\">Pr\u00fcf-\/Bestellvorschrift<\/td>\n<\/tr>\n<tr class=\"row-422\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">F02NP00355-01<\/td><td class=\"column-3\">Restschmutz \/ Residual Contamination<\/td>\n<\/tr>\n<tr class=\"row-423\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">F02NP00565-01<\/td><td class=\"column-3\">Restschmutz \/ Residual Contamination<\/td>\n<\/tr>\n<tr class=\"row-424\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">F03ZY0007N<\/td><td class=\"column-3\">Pr\u00fcdvorschrift Technische Sauberkeit - extern (Teile oder Komponenten)<\/td>\n<\/tr>\n<tr class=\"row-425\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">F0V P1914<\/td><td class=\"column-3\">Sauberkeit Fremdbezug<\/td>\n<\/tr>\n<tr class=\"row-426\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">HDEV6 Bestellvorschrift 0261 P03 739<\/td><td class=\"column-3\">Bestellvorschrift Techn. Sauberkeitsanalyse f\u00fcr Zulieferteile<\/td>\n<\/tr>\n<tr class=\"row-427\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">HDEV6 Bestellvorschrift 0261 P04 127<\/td><td class=\"column-3\">Bestellvorschrift Techn. Sauberkeitsanalyse f\u00fcr Zulieferteile<\/td>\n<\/tr>\n<tr class=\"row-428\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">LPS5 0 0261 P04 634<\/td><td class=\"column-3\">Technische Sauberkeit f\u00fcr Zulieferteile<\/td>\n<\/tr>\n<tr class=\"row-429\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">N2580-1<\/td><td class=\"column-3\">Verbot und Deklaration von Inhaltsstoffen<\/td>\n<\/tr>\n<tr class=\"row-430\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">PV 1 279 921 180<\/td><td class=\"column-3\">Pr\u00fcfvorschrift Technische Sauberkeit<\/td>\n<\/tr>\n<tr class=\"row-431\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">PV 1 279 921 533<\/td><td class=\"column-3\">Pr\u00fcfvorschrift technische Sauberkeit<\/td>\n<\/tr>\n<tr class=\"row-432\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">PV 1 279 921 535<\/td><td class=\"column-3\">Zur Pr\u00fcfvorschrift Technische Sauberkeit Aluminiumdruckguss Baukasten Epx<\/td>\n<\/tr>\n<tr class=\"row-433\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">PV 1 279 925 833<\/td><td class=\"column-3\">Anlage zur Pr\u00fcfvorschrift Technische Sauberkeit Pins f\u00fcr elektronische Steurerger\u00e4te<\/td>\n<\/tr>\n<tr class=\"row-434\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">TM_TM_00042<\/td><td class=\"column-3\">Test Method<\/td>\n<\/tr>\n<tr class=\"row-435\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">TMTM00042<\/td><td class=\"column-3\">Internal Cleanliness<\/td>\n<\/tr>\n<tr class=\"row-436\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">Y445171571<\/td><td class=\"column-3\">Pr\u00fcfmethodenblatt f\u00fcr die Sauberkeitsanalyse der Federbuchse des DMV25<\/td>\n<\/tr>\n<tr class=\"row-437\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">Y445171571<\/td><td class=\"column-3\">Sauberkeitsanalyse der Federbuchse<\/td>\n<\/tr>\n<tr class=\"row-438\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">Y44517D002<\/td><td class=\"column-3\">Cleanliness Reqirement Fremdbezug<\/td>\n<\/tr>\n<tr class=\"row-439\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">Y455132880<\/td><td class=\"column-3\">Cleanliness Requirement external procurement<\/td>\n<\/tr>\n<tr class=\"row-440\">\n\t<td class=\"column-1\">Robert Bosch GmbH<\/td><td class=\"column-2\">Y583P00204<\/td><td class=\"column-3\">Wellrohr, Verunreinigung<\/td>\n<\/tr>\n<tr class=\"row-441\">\n\t<td class=\"column-1\">SAE International<\/td><td class=\"column-2\">2001-01-0867<\/td><td class=\"column-3\">Automatic Transmissioin Hydraulic Systems<\/td>\n<\/tr>\n<tr class=\"row-442\">\n\t<td class=\"column-1\">SAE International<\/td><td class=\"column-2\">APR598B<\/td><td class=\"column-3\">Particulate Contamination in Liquid<\/td>\n<\/tr>\n<tr class=\"row-443\">\n\t<td class=\"column-1\">SAE International<\/td><td class=\"column-2\">ARP 598B<\/td><td class=\"column-3\">The determination of particulate contamination in liquids<\/td>\n<\/tr>\n<tr class=\"row-444\">\n\t<td class=\"column-1\">SAE International<\/td><td class=\"column-2\">AS4059<\/td><td class=\"column-3\">Aerospace Cleanliness for Hydraulic Fluids<\/td>\n<\/tr>\n<tr class=\"row-445\">\n\t<td class=\"column-1\">SAE International<\/td><td class=\"column-2\">AS4059A<\/td><td class=\"column-3\">Aerospace Cleanliness classification for hydraluic fluids<\/td>\n<\/tr>\n<tr class=\"row-446\">\n\t<td class=\"column-1\">SAE International<\/td><td class=\"column-2\">J1227<\/td><td class=\"column-3\">Hydraulic Fluid Components<\/td>\n<\/tr>\n<tr class=\"row-447\">\n\t<td class=\"column-1\">SAE International<\/td><td class=\"column-2\">J1726<\/td><td class=\"column-3\">Air-to-Air Charge Air Cooler<\/td>\n<\/tr>\n<tr class=\"row-448\">\n\t<td class=\"column-1\">SAE International<\/td><td class=\"column-2\">J1726<\/td><td class=\"column-3\">Charge Air Cooler<\/td>\n<\/tr>\n<tr class=\"row-449\">\n\t<td class=\"column-1\">SAE International<\/td><td class=\"column-2\">J1726<\/td><td class=\"column-3\">Air to Air Charge Air Cooler<\/td>\n<\/tr>\n<tr class=\"row-450\">\n\t<td class=\"column-1\">SAE International<\/td><td class=\"column-2\">J1726<\/td><td class=\"column-3\">Charge Air Cooler<\/td>\n<\/tr>\n<tr class=\"row-451\">\n\t<td class=\"column-1\">SAE International<\/td><td class=\"column-2\">J2045<\/td><td class=\"column-3\">Requirements for Fuel System Tubing Assemblies<\/td>\n<\/tr>\n<tr class=\"row-452\">\n\t<td class=\"column-1\">SAE International<\/td><td class=\"column-2\">WN 70\/13-1A<\/td><td class=\"column-3\">Konstruktions-Richtlinien<\/td>\n<\/tr>\n<tr class=\"row-453\">\n\t<td class=\"column-1\">Scania<\/td><td class=\"column-2\">20150810063803700<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-454\">\n\t<td class=\"column-1\">Scania<\/td><td class=\"column-2\">2001-01-0867<\/td><td class=\"column-3\">Automatic Transmission Hydraulic System Cleanliness <\/td>\n<\/tr>\n<tr class=\"row-455\">\n\t<td class=\"column-1\">Scania<\/td><td class=\"column-2\">STD4189<\/td><td class=\"column-3\">Contamination control<\/td>\n<\/tr>\n<tr class=\"row-456\">\n\t<td class=\"column-1\">Scania<\/td><td class=\"column-2\">STD4189-4<\/td><td class=\"column-3\">Surface Cleanliness in Systems<\/td>\n<\/tr>\n<tr class=\"row-457\">\n\t<td class=\"column-1\">Scania<\/td><td class=\"column-2\">STD4540<\/td><td class=\"column-3\">Determination of residual particle quantities<\/td>\n<\/tr>\n<tr class=\"row-458\">\n\t<td class=\"column-1\">Scania<\/td><td class=\"column-2\">TB1690<\/td><td class=\"column-3\">Oil System and Component Cleanliness<\/td>\n<\/tr>\n<tr class=\"row-459\">\n\t<td class=\"column-1\">Scania<\/td><td class=\"column-2\">TB1739<\/td><td class=\"column-3\">Contaminition Control <\/td>\n<\/tr>\n<tr class=\"row-460\">\n\t<td class=\"column-1\">Scania<\/td><td class=\"column-2\">TB1779<\/td><td class=\"column-3\">Technical Regulation<\/td>\n<\/tr>\n<tr class=\"row-461\">\n\t<td class=\"column-1\">Scania<\/td><td class=\"column-2\">TB1779<\/td><td class=\"column-3\">Technical Regulation Radiators<\/td>\n<\/tr>\n<tr class=\"row-462\">\n\t<td class=\"column-1\">Scania<\/td><td class=\"column-2\">TB1790<\/td><td class=\"column-3\">Axle System and Component Cleanliness<\/td>\n<\/tr>\n<tr class=\"row-463\">\n\t<td class=\"column-1\">Scania<\/td><td class=\"column-2\">TB1815<\/td><td class=\"column-3\">Gearbox and Component Cleanliness<\/td>\n<\/tr>\n<tr class=\"row-464\">\n\t<td class=\"column-1\">Scania<\/td><td class=\"column-2\">TB1831<\/td><td class=\"column-3\">Contamination control<\/td>\n<\/tr>\n<tr class=\"row-465\">\n\t<td class=\"column-1\">Scania<\/td><td class=\"column-2\">TB1832<\/td><td class=\"column-3\">Air System and Component Cleanliness<\/td>\n<\/tr>\n<tr class=\"row-466\">\n\t<td class=\"column-1\">Schabm\u00fcller<\/td><td class=\"column-2\">NAG 3<\/td><td class=\"column-3\">Analysensp\u00fclvorschrift f\u00fcr Kolbenf\u00fchrungsring<\/td>\n<\/tr>\n<tr class=\"row-467\">\n\t<td class=\"column-1\">Schaeffler<\/td><td class=\"column-2\">S252012-40<\/td><td class=\"column-3\">E-Achse Einzelkomponenten<\/td>\n<\/tr>\n<tr class=\"row-468\">\n\t<td class=\"column-1\">Schleicher<\/td><td class=\"column-2\">11481316<\/td><td class=\"column-3\">Techische Liefervorschrift<\/td>\n<\/tr>\n<tr class=\"row-469\">\n\t<td class=\"column-1\">SLPT<\/td><td class=\"column-2\">ES60011<\/td><td class=\"column-3\">Cleanliness Specification, purchased components<\/td>\n<\/tr>\n<tr class=\"row-470\">\n\t<td class=\"column-1\">Sogefi<\/td><td class=\"column-2\">QNO-04-55<\/td><td class=\"column-3\">Standard of Cleanliness<\/td>\n<\/tr>\n<tr class=\"row-471\">\n\t<td class=\"column-1\">Stahl-Eisen Pr\u00fcfblatt<\/td><td class=\"column-2\">1570<\/td><td class=\"column-3\">Mikroskopische Pr\u00fcfung von Edelst\u00e4hlen auf nichtmetallische Einschl\u00fcsse mit Bildreihen<\/td>\n<\/tr>\n<tr class=\"row-472\">\n\t<td class=\"column-1\">STD<\/td><td class=\"column-2\">STD 1088 b<\/td><td class=\"column-3\">Cleanliness of Components<\/td>\n<\/tr>\n<tr class=\"row-473\">\n\t<td class=\"column-1\">Steyr Motors<\/td><td class=\"column-2\">WN0004<\/td><td class=\"column-3\">Component \/ System Cleanliness<\/td>\n<\/tr>\n<tr class=\"row-474\">\n\t<td class=\"column-1\">Svensk<\/td><td class=\"column-2\">SS2687<\/td><td class=\"column-3\">Surface Cleanliness in Systems<\/td>\n<\/tr>\n<tr class=\"row-475\">\n\t<td class=\"column-1\">TE Connectivity<\/td><td class=\"column-2\">109-90862<\/td><td class=\"column-3\">Test specification for Cleanliness test TRW Steering Connectors<\/td>\n<\/tr>\n<tr class=\"row-476\">\n\t<td class=\"column-1\">Terra Universal<\/td><td class=\"column-2\">FS209E<\/td><td class=\"column-3\">FS209E and ISO Cleanroom Standards<\/td>\n<\/tr>\n<tr class=\"row-477\">\n\t<td class=\"column-1\">ThermoKing<\/td><td class=\"column-2\">TKS10027<\/td><td class=\"column-3\">Cleanliness Specification<\/td>\n<\/tr>\n<tr class=\"row-478\">\n\t<td class=\"column-1\">Thomas Magnete<\/td><td class=\"column-2\">AW000025<\/td><td class=\"column-3\">Pr\u00fcfvorschrift Sauberkeit, Rost, Grat, ON\/OFF 5\/2 Valve<\/td>\n<\/tr>\n<tr class=\"row-479\">\n\t<td class=\"column-1\">Thomas Magnete<\/td><td class=\"column-2\">CS 0135<\/td><td class=\"column-3\">Technical Cleanless Articles \u2013Bought-in Parts<\/td>\n<\/tr>\n<tr class=\"row-480\">\n\t<td class=\"column-1\">Thomas Magnete<\/td><td class=\"column-2\">WN 0135<\/td><td class=\"column-3\">Technische Sauberkeit Artikel Zukaufteile (extern)<\/td>\n<\/tr>\n<tr class=\"row-481\">\n\t<td class=\"column-1\">ThyssenKrupp<\/td><td class=\"column-2\">LV07200010<\/td><td class=\"column-3\">Reinheitsanforderung<\/td>\n<\/tr>\n<tr class=\"row-482\">\n\t<td class=\"column-1\">ThyssenKrupp<\/td><td class=\"column-2\">TS-00082-4<\/td><td class=\"column-3\">Camshafts<\/td>\n<\/tr>\n<tr class=\"row-483\">\n\t<td class=\"column-1\">ThyssenKrupp<\/td><td class=\"column-2\">TV-02023<\/td><td class=\"column-3\">Technische Sauberkeitsanforderungen an Bauteile und Baugruppen f\u00fcr Kfz-Lenkgetriebe<\/td>\n<\/tr>\n<tr class=\"row-484\">\n\t<td class=\"column-1\">ThyssenKrupp<\/td><td class=\"column-2\">TV-02023-DE<\/td><td class=\"column-3\">Technische Sauberkeitsanforderungen an Bauteile und Baugruppen f\u00fcr Kfz-Lenkgetriebe<\/td>\n<\/tr>\n<tr class=\"row-485\">\n\t<td class=\"column-1\">ThyssenKrupp<\/td><td class=\"column-2\">WNB-881-D<\/td><td class=\"column-3\">Sauberkeitsanforderung an Sto\u00dfd\u00e4mpferbauteile<\/td>\n<\/tr>\n<tr class=\"row-486\">\n\t<td class=\"column-1\">TI Automotive<\/td><td class=\"column-2\">C05.02.109<\/td><td class=\"column-3\">H.P. pipes cleanliness test method<\/td>\n<\/tr>\n<tr class=\"row-487\">\n\t<td class=\"column-1\">Trelleborg<\/td><td class=\"column-2\">FDDV H99 174<\/td><td class=\"column-3\">External Technicial Documents Approval form<\/td>\n<\/tr>\n<tr class=\"row-488\">\n\t<td class=\"column-1\">Tremec<\/td><td class=\"column-2\">TN-GEN003<\/td><td class=\"column-3\">Technical Cleanliness of suppliers products<\/td>\n<\/tr>\n<tr class=\"row-489\">\n\t<td class=\"column-1\">TRW automotive<\/td><td class=\"column-2\">204654<\/td><td class=\"column-3\">Cleanliness<\/td>\n<\/tr>\n<tr class=\"row-490\">\n\t<td class=\"column-1\">TRW automotive<\/td><td class=\"column-2\">235462<\/td><td class=\"column-3\">Cleanliness<\/td>\n<\/tr>\n<tr class=\"row-491\">\n\t<td class=\"column-1\">TRW automotive<\/td><td class=\"column-2\">50820219<\/td><td class=\"column-3\">Cleanliness Specification - EPS Motor Components<\/td>\n<\/tr>\n<tr class=\"row-492\">\n\t<td class=\"column-1\">TRW automotive<\/td><td class=\"column-2\">62045004<\/td><td class=\"column-3\">Kontamination hydraulischer Systeme<\/td>\n<\/tr>\n<tr class=\"row-493\">\n\t<td class=\"column-1\">TRW automotive<\/td><td class=\"column-2\">5,900,826,016<\/td><td class=\"column-3\">General Component-Cleanliness Test Specification<\/td>\n<\/tr>\n<tr class=\"row-494\">\n\t<td class=\"column-1\">TRW automotive<\/td><td class=\"column-2\">05900826 B<\/td><td class=\"column-3\">General Component-Cleanliness<\/td>\n<\/tr>\n<tr class=\"row-495\">\n\t<td class=\"column-1\">TRW automotive<\/td><td class=\"column-2\">40519B<\/td><td class=\"column-3\">Cleanliness Specification<\/td>\n<\/tr>\n<tr class=\"row-496\">\n\t<td class=\"column-1\">TRW automotive<\/td><td class=\"column-2\">A0008N7069<\/td><td class=\"column-3\">Technical Specification<\/td>\n<\/tr>\n<tr class=\"row-497\">\n\t<td class=\"column-1\">TRW automotive<\/td><td class=\"column-2\">A0025M6254<\/td><td class=\"column-3\">Cleanliness of Components and Assemblies of Steering Systems Definition<\/td>\n<\/tr>\n<tr class=\"row-498\">\n\t<td class=\"column-1\">TRW automotive<\/td><td class=\"column-2\">NW22-10-202 AE<\/td><td class=\"column-3\">Cleanliness of Components<\/td>\n<\/tr>\n<tr class=\"row-499\">\n\t<td class=\"column-1\">TRW automotive<\/td><td class=\"column-2\">S0001322<\/td><td class=\"column-3\">Cleanliness of Components abd Assemblies of Steering Systems <\/td>\n<\/tr>\n<tr class=\"row-500\">\n\t<td class=\"column-1\">TRW automotive<\/td><td class=\"column-2\">S-13834400<\/td><td class=\"column-3\">Specification<\/td>\n<\/tr>\n<tr class=\"row-501\">\n\t<td class=\"column-1\">TRW automotive<\/td><td class=\"column-2\">S-13834400 A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-502\">\n\t<td class=\"column-1\">TRW automotive<\/td><td class=\"column-2\">S-13834400 B<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-503\">\n\t<td class=\"column-1\">TRW automotive<\/td><td class=\"column-2\">TRW62045004<\/td><td class=\"column-3\">Kontamination hydraulischer Systeme<\/td>\n<\/tr>\n<tr class=\"row-504\">\n\t<td class=\"column-1\">U.S. Pharmacopeia<\/td><td class=\"column-2\">788<\/td><td class=\"column-3\">Particulate Matter in Injections<\/td>\n<\/tr>\n<tr class=\"row-505\">\n\t<td class=\"column-1\">Valeo<\/td><td class=\"column-2\">400,530,004<\/td><td class=\"column-3\">Recommendations for the control of the cleanless level of CMC-CRC-CSC components <\/td>\n<\/tr>\n<tr class=\"row-506\">\n\t<td class=\"column-1\">Valeo<\/td><td class=\"column-2\">400,530,011<\/td><td class=\"column-3\">Cleanliss requirements<\/td>\n<\/tr>\n<tr class=\"row-507\">\n\t<td class=\"column-1\">Valeo<\/td><td class=\"column-2\">8888477662<\/td><td class=\"column-3\">CMA Water Chiller Assembly<\/td>\n<\/tr>\n<tr class=\"row-508\">\n\t<td class=\"column-1\">Valeo<\/td><td class=\"column-2\">CTS BMW L7 SPOC Rev G<\/td><td class=\"column-3\">Transmission Oil Cooler<\/td>\n<\/tr>\n<tr class=\"row-509\">\n\t<td class=\"column-1\">Valeo<\/td><td class=\"column-2\">DIN8964<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-510\">\n\t<td class=\"column-1\">Valeo<\/td><td class=\"column-2\">MCV_SPOC_A<\/td><td class=\"column-3\">DME\/EME Cooler<\/td>\n<\/tr>\n<tr class=\"row-511\">\n\t<td class=\"column-1\">Valeo<\/td><td class=\"column-2\">PDT NVF 10021 Rev A<\/td><td class=\"column-3\">Component Cleanliness for brazed heatexchangers<\/td>\n<\/tr>\n<tr class=\"row-512\">\n\t<td class=\"column-1\">Valeo<\/td><td class=\"column-2\">VECFS-PVP-003<\/td><td class=\"column-3\">GET-Validation Test Schedule Matrix<\/td>\n<\/tr>\n<tr class=\"row-513\">\n\t<td class=\"column-1\">Verband der Automobilindustrie<\/td><td class=\"column-2\">VDA-19 Band 1<\/td><td class=\"column-3\">Pr\u00fcfung der technischen Sauberkeit \/ Inspection of Technical Cleanliness<\/td>\n<\/tr>\n<tr class=\"row-514\">\n\t<td class=\"column-1\">Verband der Automobilindustrie<\/td><td class=\"column-2\">VDA-19 Band 2<\/td><td class=\"column-3\">Technical Cleanliness in assembly<\/td>\n<\/tr>\n<tr class=\"row-515\">\n\t<td class=\"column-1\">Verband der Ingenieure<\/td><td class=\"column-2\">VDI 2083<\/td><td class=\"column-3\">Reinraumtechnik<\/td>\n<\/tr>\n<tr class=\"row-516\">\n\t<td class=\"column-1\">Verein Deutscher Ingenieure <\/td><td class=\"column-2\">VDI2083-21<\/td><td class=\"column-3\">Reinraumtechnik Reinheit von Medizinprodukten im Herstellungsprozess<\/td>\n<\/tr>\n<tr class=\"row-517\">\n\t<td class=\"column-1\">Verein Deutscher Ingenieure <\/td><td class=\"column-2\">VDI3492 6.12<\/td><td class=\"column-3\">Messen von Innenraumluftverunreinigungen <\/td>\n<\/tr>\n<tr class=\"row-518\">\n\t<td class=\"column-1\">Verein Deutscher Ingenieure <\/td><td class=\"column-2\">VDI3866.5 6.17<\/td><td class=\"column-3\">Bestimmung von Asbest in technischen Produkten<\/td>\n<\/tr>\n<tr class=\"row-519\">\n\t<td class=\"column-1\">VM Motori<\/td><td class=\"column-2\">PS NP030\/DIT<\/td><td class=\"column-3\">Engine Component Cleaning<\/td>\n<\/tr>\n<tr class=\"row-520\">\n\t<td class=\"column-1\">VM Motori<\/td><td class=\"column-2\">PS NP030\/DIT<\/td><td class=\"column-3\">Engine Component Cleaning<\/td>\n<\/tr>\n<tr class=\"row-521\">\n\t<td class=\"column-1\">Voith<\/td><td class=\"column-2\">VN3221<\/td><td class=\"column-3\">Business Unit Commercial Vehicles Voith Turbo<\/td>\n<\/tr>\n<tr class=\"row-522\">\n\t<td class=\"column-1\">Voith<\/td><td class=\"column-2\">VN3221<\/td><td class=\"column-3\">Voith Turbo Bauteilesauberkeit <\/td>\n<\/tr>\n<tr class=\"row-523\">\n\t<td class=\"column-1\">Volkswagen<\/td><td class=\"column-2\">50093<\/td><td class=\"column-3\">Porosit\u00e4t von Gussteilen<\/td>\n<\/tr>\n<tr class=\"row-524\">\n\t<td class=\"column-1\">Volkswagen<\/td><td class=\"column-2\">96435<\/td><td class=\"column-3\">Pr\u00fcfung auf Verunreinigung Leitungen\/ Schl\u00e4uche\/ Rohre<\/td>\n<\/tr>\n<tr class=\"row-525\">\n\t<td class=\"column-1\">Volkswagen<\/td><td class=\"column-2\">HVSM_YYYY_SYS_ANF_TECH<\/td><td class=\"column-3\">Sauberkeitsanforderungen f\u00fcr Batteriesysteme TDO V03.986.764_EN<\/td>\n<\/tr>\n<tr class=\"row-526\">\n\t<td class=\"column-1\">Volkswagen<\/td><td class=\"column-2\">LAH.80A.816..F<\/td><td class=\"column-3\">Gask\u00fchler R744<\/td>\n<\/tr>\n<tr class=\"row-527\">\n\t<td class=\"column-1\">Volkswagen<\/td><td class=\"column-2\">P VW 3.10.7<\/td><td class=\"column-3\">Farben und Lacke<\/td>\n<\/tr>\n<tr class=\"row-528\">\n\t<td class=\"column-1\">Volkswagen<\/td><td class=\"column-2\">PV3336<\/td><td class=\"column-3\">Sauberkeit von Leitungen und Kreislaufteilen<\/td>\n<\/tr>\n<tr class=\"row-529\">\n\t<td class=\"column-1\">Volkswagen<\/td><td class=\"column-2\">PV3345<\/td><td class=\"column-3\">Automatikgetriebe und periphere Baugruppen<\/td>\n<\/tr>\n<tr class=\"row-530\">\n\t<td class=\"column-1\">Volkswagen<\/td><td class=\"column-2\">PV3347<\/td><td class=\"column-3\">Sauberkeit von Motorenbauteilen<\/td>\n<\/tr>\n<tr class=\"row-531\">\n\t<td class=\"column-1\">Volkswagen<\/td><td class=\"column-2\">PV3347<\/td><td class=\"column-3\">Sauberkeit von Motorenbauteilen<\/td>\n<\/tr>\n<tr class=\"row-532\">\n\t<td class=\"column-1\">Volkswagen<\/td><td class=\"column-2\">PV3347<\/td><td class=\"column-3\">Sauberkeitsanalyse von Dichtflansch vorne V6 TDI Generation 1<\/td>\n<\/tr>\n<tr class=\"row-533\">\n\t<td class=\"column-1\">Volkswagen<\/td><td class=\"column-2\">PV3349<\/td><td class=\"column-3\">Sauberkeit von ZSB Schaltgetriebe und Einzelteilen<\/td>\n<\/tr>\n<tr class=\"row-534\">\n\t<td class=\"column-1\">Volkswagen<\/td><td class=\"column-2\">PV3370<\/td><td class=\"column-3\">Automatikgetriebe, Schaltgetriebe mit besonderen Anforderungen<\/td>\n<\/tr>\n<tr class=\"row-535\">\n\t<td class=\"column-1\">Volkswagen<\/td><td class=\"column-2\">PV3370<\/td><td class=\"column-3\">Automatic Transmission, Manual Transmission with special Requirements<\/td>\n<\/tr>\n<tr class=\"row-536\">\n\t<td class=\"column-1\">Volkswagen<\/td><td class=\"column-2\">PV3370<\/td><td class=\"column-3\">Automatik-, Schaltgetrieben, E-Antrieben und deren Einzelbauteilen<\/td>\n<\/tr>\n<tr class=\"row-537\">\n\t<td class=\"column-1\">Volkswagen<\/td><td class=\"column-2\">PV3678<\/td><td class=\"column-3\">Restschmutz im W\u00e4rmetauscher<\/td>\n<\/tr>\n<tr class=\"row-538\">\n\t<td class=\"column-1\">Volkswagen<\/td><td class=\"column-2\">PV6093<\/td><td class=\"column-3\">Porosit\u00e4tsbestimmung<\/td>\n<\/tr>\n<tr class=\"row-539\">\n\t<td class=\"column-1\">Volkswagen<\/td><td class=\"column-2\">PV8205<\/td><td class=\"column-3\">Restschmutzbestimmung<\/td>\n<\/tr>\n<tr class=\"row-540\">\n\t<td class=\"column-1\">Volkswagen<\/td><td class=\"column-2\">PV8220<\/td><td class=\"column-3\">Sauberkeitsanalyse Komponenten K\u00e4ltemittelkreislauf<\/td>\n<\/tr>\n<tr class=\"row-541\">\n\t<td class=\"column-1\">Volkswagen<\/td><td class=\"column-2\">TL82086<\/td><td class=\"column-3\">K\u00e4ltemittelw\u00e4rmetauscher<\/td>\n<\/tr>\n<tr class=\"row-542\">\n\t<td class=\"column-1\">Volkswagen<\/td><td class=\"column-2\">TL82086<\/td><td class=\"column-3\">Refrigerant Heat Exchanger<\/td>\n<\/tr>\n<tr class=\"row-543\">\n\t<td class=\"column-1\">Volkswagen<\/td><td class=\"column-2\">TL82284<\/td><td class=\"column-3\">Servolenkgetriebe mit Au\u00dfenabtrieb<\/td>\n<\/tr>\n<tr class=\"row-544\">\n\t<td class=\"column-1\">Volkswagen<\/td><td class=\"column-2\">TL82316<\/td><td class=\"column-3\">K\u00e4ltemittelleitungen R134a \/ R1234yf<\/td>\n<\/tr>\n<tr class=\"row-545\">\n\t<td class=\"column-1\">Volkswagen<\/td><td class=\"column-2\">VW 80000<\/td><td class=\"column-3\">Electric and Electronic Components un Motor Vehicles up to 3,5 t<\/td>\n<\/tr>\n<tr class=\"row-546\">\n\t<td class=\"column-1\">Volkswagen<\/td><td class=\"column-2\">VW 96435<\/td><td class=\"column-3\">Pr\u00fcfung auf Verunreinigung - Bestimmung der Restpartikelmengen<\/td>\n<\/tr>\n<tr class=\"row-547\">\n\t<td class=\"column-1\">Volkswagen<\/td><td class=\"column-2\">VW01134<\/td><td class=\"column-3\">Sauberkeitsanforderung an Motorenbauteile<\/td>\n<\/tr>\n<tr class=\"row-548\">\n\t<td class=\"column-1\">Volkswagen<\/td><td class=\"column-2\">VW01134<\/td><td class=\"column-3\">Sauberkeitsanforderungen an Motorenbauteilen<\/td>\n<\/tr>\n<tr class=\"row-549\">\n\t<td class=\"column-1\">Volkswagen<\/td><td class=\"column-2\">VW01135<\/td><td class=\"column-3\">Mediunf\u00fchrende Motoranbauteile<\/td>\n<\/tr>\n<tr class=\"row-550\">\n\t<td class=\"column-1\">Volkswagen<\/td><td class=\"column-2\">VW01135<\/td><td class=\"column-3\">Engine-Mounted Parts that Convey Media<\/td>\n<\/tr>\n<tr class=\"row-551\">\n\t<td class=\"column-1\">Volkswagen<\/td><td class=\"column-2\">VW01136<\/td><td class=\"column-3\">Mediunf\u00fchrende Motoranbauteile<\/td>\n<\/tr>\n<tr class=\"row-552\">\n\t<td class=\"column-1\">Volkswagen<\/td><td class=\"column-2\">VW01137<\/td><td class=\"column-3\">Sauberkeitsanforderung f\u00fcr k\u00fchlmittelf\u00fchrende Bauteile<\/td>\n<\/tr>\n<tr class=\"row-553\">\n\t<td class=\"column-1\">Volkswagen<\/td><td class=\"column-2\">VW01139<\/td><td class=\"column-3\">ZSB-Lenksysteme und Einzelteile<\/td>\n<\/tr>\n<tr class=\"row-554\">\n\t<td class=\"column-1\">Volkswagen<\/td><td class=\"column-2\">VW96280<\/td><td class=\"column-3\">Zul\u00e4ssiger Restschmutz in \u00f6lf\u00fchrenden Bauteilen<\/td>\n<\/tr>\n<tr class=\"row-555\">\n\t<td class=\"column-1\">Volvo<\/td><td class=\"column-2\">STD107-0001<\/td><td class=\"column-3\">Component Cleanliness<\/td>\n<\/tr>\n<tr class=\"row-556\">\n\t<td class=\"column-1\">Volvo<\/td><td class=\"column-2\">STD107-0002<\/td><td class=\"column-3\">Cleanliness of Components and Systems<\/td>\n<\/tr>\n<tr class=\"row-557\">\n\t<td class=\"column-1\">Volvo<\/td><td class=\"column-2\">STD5091,03<\/td><td class=\"column-3\">Terminology<\/td>\n<\/tr>\n<tr class=\"row-558\">\n\t<td class=\"column-1\">Volvo<\/td><td class=\"column-2\">STD5091,15<\/td><td class=\"column-3\">Cleanliness of Parts, Components and Systems<\/td>\n<\/tr>\n<tr class=\"row-559\">\n\t<td class=\"column-1\">Volvo<\/td><td class=\"column-2\">VCS5091,159<\/td><td class=\"column-3\">Cleanliness of Components and Systems<\/td>\n<\/tr>\n<tr class=\"row-560\">\n\t<td class=\"column-1\">Volvo<\/td><td class=\"column-2\">VCS5091,159 (Issue 15)<\/td><td class=\"column-3\">Cleanliness of Components and Systems<\/td>\n<\/tr>\n<tr class=\"row-561\">\n\t<td class=\"column-1\">Volvo<\/td><td class=\"column-2\">VCS5091,159 (Issue 16)<\/td><td class=\"column-3\">Cleanliness of Components and Systems<\/td>\n<\/tr>\n<tr class=\"row-562\">\n\t<td class=\"column-1\">Volvo<\/td><td class=\"column-2\">VCS5091,71<\/td><td class=\"column-3\">Cleanlines Testing frequency<\/td>\n<\/tr>\n<tr class=\"row-563\">\n\t<td class=\"column-1\">Wabco<\/td><td class=\"column-2\">JED593<\/td><td class=\"column-3\">Sauberkeit von Teilen und Ger\u00e4ten <\/td>\n<\/tr>\n<tr class=\"row-564\">\n\t<td class=\"column-1\">Wabco<\/td><td class=\"column-2\">JED593<\/td><td class=\"column-3\">Cleanliness of parts and devices <\/td>\n<\/tr>\n<tr class=\"row-565\">\n\t<td class=\"column-1\">Wahler<\/td><td class=\"column-2\">WA-N630000<\/td><td class=\"column-3\">Bauteilsauberkeit<\/td>\n<\/tr>\n<tr class=\"row-566\">\n\t<td class=\"column-1\">WeberHydraulik<\/td><td class=\"column-2\">632.111.9<\/td><td class=\"column-3\">SAUBERKEIT VON EINZELTEILEN UND BAUGRUPPEN<\/td>\n<\/tr>\n<tr class=\"row-567\">\n\t<td class=\"column-1\">Witzenmann<\/td><td class=\"column-2\">CV<\/td><td class=\"column-3\">Cleanliness Verification<\/td>\n<\/tr>\n<tr class=\"row-568\">\n\t<td class=\"column-1\">Witzenmann<\/td><td class=\"column-2\">PA61-113 <\/td><td class=\"column-3\">Pr\u00fcfanweisung zur Bestimmung der Sauberkeit<\/td>\n<\/tr>\n<tr class=\"row-569\">\n\t<td class=\"column-1\">Witzenmann<\/td><td class=\"column-2\">PA61-113 Rev 0<\/td><td class=\"column-3\">PA zur Bestimmung der Sauberkeit<\/td>\n<\/tr>\n<tr class=\"row-570\">\n\t<td class=\"column-1\">Witzenmann<\/td><td class=\"column-2\">PA61-113 REV01 Anlage1<\/td><td class=\"column-3\">Pr\u00fcfanweisung zur Bestimmung der Sauberkeit- Darstellung des Pr\u00fcfablaufs<\/td>\n<\/tr>\n<tr class=\"row-571\">\n\t<td class=\"column-1\">Witzenmann<\/td><td class=\"column-2\">IBTS<\/td><td class=\"column-3\">Infoblatt zur Technischen Sauberkeit<\/td>\n<\/tr>\n<tr class=\"row-572\">\n\t<td class=\"column-1\">Woco<\/td><td class=\"column-2\">WN730010<\/td><td class=\"column-3\">Technische Sauberkei (Zukaufteile\/Fertigartikel) \/ Technical specification (purchased parts \/ mass-produced articles)<\/td>\n<\/tr>\n<tr class=\"row-573\">\n\t<td class=\"column-1\">ZF Friedrichshafen<\/td><td class=\"column-2\">1000000154595<\/td><td class=\"column-3\">Sauberkeit von Wandlerteilen<\/td>\n<\/tr>\n<tr class=\"row-574\">\n\t<td class=\"column-1\">ZF Friedrichshafen<\/td><td class=\"column-2\">1,000,000,154,595<\/td><td class=\"column-3\">Pr\u00fcfvorschrift inspection specification<\/td>\n<\/tr>\n<tr class=\"row-575\">\n\t<td class=\"column-1\">ZF Friedrichshafen<\/td><td class=\"column-2\">1,000,000,154,595<\/td><td class=\"column-3\">Sauberkeit von Wandlerteilen<\/td>\n<\/tr>\n<tr class=\"row-576\">\n\t<td class=\"column-1\">ZF Friedrichshafen<\/td><td class=\"column-2\">1,000,000,767,571<\/td><td class=\"column-3\">Sauberkeit nasslaufender Anfahrelemente 8P \/ 8HP 4. Gen<\/td>\n<\/tr>\n<tr class=\"row-577\">\n\t<td class=\"column-1\">ZF Friedrichshafen<\/td><td class=\"column-2\">0000 700 815 g<\/td><td class=\"column-3\">Restschmutzbestimmung an Getriebebauteilen<\/td>\n<\/tr>\n<tr class=\"row-578\">\n\t<td class=\"column-1\">ZF Friedrichshafen<\/td><td class=\"column-2\">0000 700 815 h<\/td><td class=\"column-3\">Sauberkeitsuntersuchungen an Getriebebauteilen mittles Ultraschall Extraktion<\/td>\n<\/tr>\n<tr class=\"row-579\">\n\t<td class=\"column-1\">ZF Friedrichshafen<\/td><td class=\"column-2\">0000 701 604 g<\/td><td class=\"column-3\">Sauberkeit von Getriebebauteilen<\/td>\n<\/tr>\n<tr class=\"row-580\">\n\t<td class=\"column-1\">ZF Friedrichshafen<\/td><td class=\"column-2\">0000 701 604 h<\/td><td class=\"column-3\">Sauberkeit von Getriebeteilen<\/td>\n<\/tr>\n<tr class=\"row-581\">\n\t<td class=\"column-1\">ZF Friedrichshafen<\/td><td class=\"column-2\">0000 702 190 a<\/td><td class=\"column-3\">Specification<\/td>\n<\/tr>\n<tr class=\"row-582\">\n\t<td class=\"column-1\">ZF Friedrichshafen<\/td><td class=\"column-2\">0000 702 190 b<\/td><td class=\"column-3\">Technische Oberfl\u00e4chenreinheit<\/td>\n<\/tr>\n<tr class=\"row-583\">\n\t<td class=\"column-1\">ZF Friedrichshafen<\/td><td class=\"column-2\">0000 702 190 c<\/td><td class=\"column-3\">Technische Oberfl\u00e4chenreinheit<\/td>\n<\/tr>\n<tr class=\"row-584\">\n\t<td class=\"column-1\">ZF Friedrichshafen<\/td><td class=\"column-2\">0000 702 190 c<\/td><td class=\"column-3\">Technische Oberfl\u00e4chenreinheit<\/td>\n<\/tr>\n<tr class=\"row-585\">\n\t<td class=\"column-1\">ZF Friedrichshafen<\/td><td class=\"column-2\">0000 703 169 <\/td><td class=\"column-3\">Bestimmung der Technischen Sauberkeit durch Mitteldruckspritzen<\/td>\n<\/tr>\n<tr class=\"row-586\">\n\t<td class=\"column-1\">ZF Friedrichshafen<\/td><td class=\"column-2\">1Q40 153 454<\/td><td class=\"column-3\">Ermittlung der Technischen Oberfl\u00e4chenreinheit<\/td>\n<\/tr>\n<tr class=\"row-587\">\n\t<td class=\"column-1\">ZF Friedrichshafen<\/td><td class=\"column-2\">A008V5448 Rev. A<\/td><td class=\"column-3\">Technical Specification Braking Electronics - Cleanliness Spec. For metallic contamination<\/td>\n<\/tr>\n<tr class=\"row-588\">\n\t<td class=\"column-1\">ZF Friedrichshafen<\/td><td class=\"column-2\">WN70\/13<\/td><td class=\"column-3\">Vorgaben Technische Sauberkeit<\/td>\n<\/tr>\n<tr class=\"row-589\">\n\t<td class=\"column-1\">ZF Friedrichshafen<\/td><td class=\"column-2\">WN70-13<\/td><td class=\"column-3\">Ermitteln von Schmutzr\u00fcckst\u00e4nden<\/td>\n<\/tr>\n<tr class=\"row-590\">\n\t<td class=\"column-1\">ZF Friedrichshafen<\/td><td class=\"column-2\">ZF 1332<\/td><td class=\"column-3\">Technische Sauberkeit von ZFProdukten<\/td>\n<\/tr>\n<tr class=\"row-591\">\n\t<td class=\"column-1\">ZF Friedrichshafen<\/td><td class=\"column-2\">ZF1000000126728<\/td><td class=\"column-3\">Ermittlung von Restschmutzmengen<\/td>\n<\/tr>\n<tr class=\"row-592\">\n\t<td class=\"column-1\">ZF Friedrichshafen<\/td><td class=\"column-2\">ZF1Q40153454<\/td><td class=\"column-3\">Technische Oberfl\u00e4chenreinheit<\/td>\n<\/tr>\n<tr class=\"row-593\">\n\t<td class=\"column-1\">ZF Friedrichshafen<\/td><td class=\"column-2\">ZFLS N 5-1<\/td><td class=\"column-3\">Sauberkeit von ZFLS-Produkten Pr\u00fcfvorschriften<\/td>\n<\/tr>\n<tr class=\"row-594\">\n\t<td class=\"column-1\">ZF Friedrichshafen<\/td><td class=\"column-2\">ZFN 1132<\/td><td class=\"column-3\">Technische Sauberkeit von ZF-Produkten<\/td>\n<\/tr>\n<tr class=\"row-595\">\n\t<td class=\"column-1\">ZF Friedrichshafen<\/td><td class=\"column-2\">ZFN 5008-1<\/td><td class=\"column-3\">Sauberkeit von ZF-Produkten<\/td>\n<\/tr>\n<tr class=\"row-596\">\n\t<td class=\"column-1\">ZF Friedrichshafen<\/td><td class=\"column-2\">ZFN 5008-2<\/td><td class=\"column-3\">Sauberkeit von ZF-Produkten<\/td>\n<\/tr>\n<tr class=\"row-597\">\n\t<td class=\"column-1\">ZF Friedrichshafen<\/td><td class=\"column-2\">ZFN 5008-3<\/td><td class=\"column-3\">Sauberkeit von ZF-Produkten<\/td>\n<\/tr>\n<tr class=\"row-598\">\n\t<td class=\"column-1\">ZF Sachs<\/td><td class=\"column-2\">624-624-650-1<\/td><td class=\"column-3\">Sauberkeit von HCC-Teilen<\/td>\n<\/tr>\n<tr class=\"row-599\">\n\t<td class=\"column-1\">ZF Sachs<\/td><td class=\"column-2\">AA-DWC-NA-0001.0<\/td><td class=\"column-3\">Qualit\u00e4tssicherung Nasslaufende Anfahrelemente<\/td>\n<\/tr>\n<tr class=\"row-600\">\n\t<td class=\"column-1\">ZF Sachs<\/td><td class=\"column-2\">PV 1000000149830<\/td><td class=\"column-3\">Sauberkeit von HCC-Teilen<\/td>\n<\/tr>\n<tr class=\"row-601\">\n\t<td class=\"column-1\">ZF Sachs<\/td><td class=\"column-2\">PV-DWC-ZSB-0001.3<\/td><td class=\"column-3\">Sauberkeit von Doppelkupplungsteilen<\/td>\n<\/tr>\n<tr class=\"row-602\">\n\t<td class=\"column-1\">ZF Sachs<\/td><td class=\"column-2\">PV-DWC-ZSB-0001.3<\/td><td class=\"column-3\">Pr\u00fcfvorschrift zur Restschmutzbestimmung<\/td>\n<\/tr>\n<tr class=\"row-603\">\n\t<td class=\"column-1\">ZF Sachs<\/td><td class=\"column-2\">PV-WA-ZSB-0002.1<\/td><td class=\"column-3\">Sauberkeit von Wandlerteilen<\/td>\n<\/tr>\n<tr class=\"row-604\">\n\t<td class=\"column-1\">ZF Sachs<\/td><td class=\"column-2\">WN 70\/13, VDA Bd. 19, ISO 16232<\/td><td class=\"column-3\">Analysenvorschrift<\/td>\n<\/tr>\n<tr class=\"row-605\">\n\t<td class=\"column-1\">ZF Sachs<\/td><td class=\"column-2\">WN70\/13<\/td><td class=\"column-3\">boites Vitesses Manuells-Proprete<\/td>\n<\/tr>\n<tr class=\"row-606\">\n\t<td class=\"column-1\">ZF Sachs<\/td><td class=\"column-2\">WN70\/13<\/td><td class=\"column-3\">Vorgaben Technische Sauberkeit<\/td>\n<\/tr>\n<tr class=\"row-607\">\n\t<td class=\"column-1\">ZF Sachs<\/td><td class=\"column-2\">WN70\/13<\/td><td class=\"column-3\">Vorgaben Technische Sauberkeit<\/td>\n<\/tr>\n<tr class=\"row-608\">\n\t<td class=\"column-1\">ZF Sachs<\/td><td class=\"column-2\">WN70\/13<\/td><td class=\"column-3\">Ermitteln von Schmutzr\u00fcckst\u00e4nden an Einzelteilen<\/td>\n<\/tr>\n<tr class=\"row-609\">\n\t<td class=\"column-1\">ZF TRW<\/td><td class=\"column-2\">235462<\/td><td class=\"column-3\">ZF General Specification for Claenliness<\/td>\n<\/tr>\n<tr class=\"row-610\">\n\t<td class=\"column-1\">ZF TRW<\/td><td class=\"column-2\">A0008N7069<\/td><td class=\"column-3\">Cleanliness of components and assemblies of brakins systems definition and classifi.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-33 elementor-top-column elementor-element elementor-element-720f6ca4\" data-id=\"720f6ca4\" data-element_type=\"column\" data-e-type=\"column\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-97d87ff elementor-widget elementor-widget-global elementor-global-7813 elementor-widget-toggle\" data-id=\"97d87ff\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"toggle.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-toggle\">\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<h3 id=\"elementor-tab-title-1591\" class=\"elementor-tab-title\" data-tab=\"1\" role=\"button\" aria-controls=\"elementor-tab-content-1591\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-right\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><i class=\"fas fa-chevron-down\"><\/i><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><i class=\"elementor-toggle-icon-opened fas fa-chevron-up\"><\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Navigator<\/a>\n\t\t\t\t\t<\/h3>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-1591\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"1\" role=\"region\" aria-labelledby=\"elementor-tab-title-1591\"><p>\t\t<div data-elementor-type=\"section\" data-elementor-id=\"7797\" class=\"elementor elementor-7797\" data-elementor-post-type=\"elementor_library\">\n\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-47a631bc elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"47a631bc\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-385db134\" data-id=\"385db134\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-5d580a2 elementor-widget elementor-widget-heading\" data-id=\"5d580a2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Restschmutzanalyse<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-29bace0 elementor-nav-menu__align-start elementor-nav-menu--dropdown-none elementor-widget elementor-widget-nav-menu\" data-id=\"29bace0\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;layout&quot;:&quot;vertical&quot;,&quot;submenu_icon&quot;:{&quot;value&quot;:&quot;&lt;i class=\\&quot;fas fa-caret-down\\&quot; aria-hidden=\\&quot;true\\&quot;&gt;&lt;\\\/i&gt;&quot;,&quot;library&quot;:&quot;fa-solid&quot;}}\" data-widget_type=\"nav-menu.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t<nav aria-label=\"Menu\" class=\"elementor-nav-menu--main elementor-nav-menu__container elementor-nav-menu--layout-vertical e--pointer-none\">\n\t\t\t\t<ul id=\"menu-1-29bace0\" class=\"elementor-nav-menu sm-vertical\"><li class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-7792\"><a href=\"https:\/\/www.rjl-microanalytic.de\/en\/restschmutzanalyse-technische-sauberkeit-vda-19-iso-16232\/\" class=\"elementor-item\">(1) Restschmutzanalyse<\/a><\/li>\n<li class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-7793\"><a href=\"https:\/\/www.rjl-microanalytic.de\/en\/restschmutzanalyse-technische-sauberkeit-vda-19-iso-16232\/grundlagen-restschmutz-technische-sauberkeit\/\" class=\"elementor-item\">(2) Was ist Technische Sauberkeit?<\/a><\/li>\n<li class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-7794\"><a href=\"https:\/\/www.rjl-microanalytic.de\/en\/restschmutzanalyse-technische-sauberkeit-vda-19-iso-16232\/pruefnormen-pruefvorschriften-restschmutz-technische-sauberkeit\/\" class=\"elementor-item\">(3) Pr\u00fcfnormen &#038; Vorschriften<\/a><\/li>\n<li class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-7795\"><a href=\"https:\/\/www.rjl-microanalytic.de\/en\/restschmutzanalyse-technische-sauberkeit-vda-19-iso-16232\/seminar-vda-19-iso-16232\/\" class=\"elementor-item\">(4) Seminare VDA-19 &#038; ISO-16232<\/a><\/li>\n<li class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-7796\"><a href=\"https:\/\/www.rjl-microanalytic.de\/en\/analysenservice-mit-iso-17025-akkreditierung\/\" class=\"elementor-item\">(5) Analysen mit Akkreditierung<\/a><\/li>\n<\/ul>\t\t\t<\/nav>\n\t\t\t\t\t\t<nav class=\"elementor-nav-menu--dropdown elementor-nav-menu__container\" aria-hidden=\"true\">\n\t\t\t\t<ul id=\"menu-2-29bace0\" class=\"elementor-nav-menu sm-vertical\"><li class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-7792\"><a href=\"https:\/\/www.rjl-microanalytic.de\/en\/restschmutzanalyse-technische-sauberkeit-vda-19-iso-16232\/\" class=\"elementor-item\" tabindex=\"-1\">(1) Restschmutzanalyse<\/a><\/li>\n<li class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-7793\"><a href=\"https:\/\/www.rjl-microanalytic.de\/en\/restschmutzanalyse-technische-sauberkeit-vda-19-iso-16232\/grundlagen-restschmutz-technische-sauberkeit\/\" class=\"elementor-item\" tabindex=\"-1\">(2) Was ist Technische Sauberkeit?<\/a><\/li>\n<li class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-7794\"><a href=\"https:\/\/www.rjl-microanalytic.de\/en\/restschmutzanalyse-technische-sauberkeit-vda-19-iso-16232\/pruefnormen-pruefvorschriften-restschmutz-technische-sauberkeit\/\" class=\"elementor-item\" tabindex=\"-1\">(3) Pr\u00fcfnormen &#038; Vorschriften<\/a><\/li>\n<li class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-7795\"><a href=\"https:\/\/www.rjl-microanalytic.de\/en\/restschmutzanalyse-technische-sauberkeit-vda-19-iso-16232\/seminar-vda-19-iso-16232\/\" class=\"elementor-item\" tabindex=\"-1\">(4) Seminare VDA-19 &#038; ISO-16232<\/a><\/li>\n<li class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-7796\"><a href=\"https:\/\/www.rjl-microanalytic.de\/en\/analysenservice-mit-iso-17025-akkreditierung\/\" class=\"elementor-item\" tabindex=\"-1\">(5) Analysen mit Akkreditierung<\/a><\/li>\n<\/ul>\t\t\t<\/nav>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<h3 id=\"elementor-tab-title-1592\" class=\"elementor-tab-title\" data-tab=\"2\" role=\"button\" aria-controls=\"elementor-tab-content-1592\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-right\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><i class=\"fas fa-chevron-down\"><\/i><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><i class=\"elementor-toggle-icon-opened fas fa-chevron-up\"><\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">News-Blog<\/a>\n\t\t\t\t\t<\/h3>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-1592\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"2\" role=\"region\" aria-labelledby=\"elementor-tab-title-1592\"><p>\t\t<div data-elementor-type=\"section\" data-elementor-id=\"4911\" class=\"elementor elementor-4911\" data-elementor-post-type=\"elementor_library\">\n\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-685e1a5e elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"685e1a5e\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-58883b11\" data-id=\"58883b11\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-5115ac0a elementor-widget elementor-widget-heading\" data-id=\"5115ac0a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><a href=\"\/kategorie\/innovative-analytik\/analyse-technische-sauberkeit\/\">Sauberkeitsanalyse<\/a><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3bcde25b elementor-grid-1 elementor-posts--thumbnail-left elementor-posts--align-left elementor-grid-tablet-1 elementor-grid-mobile-1 elementor-widget elementor-widget-posts\" data-id=\"3bcde25b\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;classic_columns&quot;:&quot;1&quot;,&quot;classic_row_gap&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:30,&quot;sizes&quot;:[]},&quot;classic_columns_tablet&quot;:&quot;1&quot;,&quot;classic_columns_mobile&quot;:&quot;1&quot;,&quot;classic_row_gap_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;classic_row_gap_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]}}\" data-widget_type=\"posts.classic\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-posts-container elementor-posts elementor-posts--skin-classic elementor-grid\" role=\"list\">\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-15998 post type-post status-publish format-standard has-post-thumbnail hentry category-rjl-firmennachrichten category-innovative-analytik category-analyse-technische-sauberkeit tag-soziales-engagement\" role=\"listitem\">\n\t\t\t\t<a class=\"elementor-post__thumbnail__link\" href=\"https:\/\/www.rjl-microanalytic.de\/en\/nachricht-von-unserem-patenkind-in-uganda\/\" tabindex=\"-1\" >\n\t\t\t<div class=\"elementor-post__thumbnail\"><img decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/Projekthilfe_Uganda_Schulunterricht-150x150.jpg\" class=\"attachment-thumbnail size-thumbnail wp-image-15991\" alt=\"\" srcset=\"https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/Projekthilfe_Uganda_Schulunterricht-150x150.jpg 150w, https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/Projekthilfe_Uganda_Schulunterricht-300x300.jpg 300w, https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/Projekthilfe_Uganda_Schulunterricht-1020x1024.jpg 1020w, https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/Projekthilfe_Uganda_Schulunterricht-768x771.jpg 768w, https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/Projekthilfe_Uganda_Schulunterricht-1530x1536.jpg 1530w, https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/Projekthilfe_Uganda_Schulunterricht-12x12.jpg 12w, https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/Projekthilfe_Uganda_Schulunterricht.jpg 1656w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><\/div>\n\t\t<\/a>\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h3 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/www.rjl-microanalytic.de\/en\/nachricht-von-unserem-patenkind-in-uganda\/\" >\n\t\t\t\tNachricht von unserem Patenkind in Uganda\t\t\t<\/a>\n\t\t<\/h3>\n\t\t\t\t<\/div>\n\t\t\t\t<\/article>\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-15959 post type-post status-publish format-standard has-post-thumbnail hentry category-rjl-firmennachrichten category-innovative-analytik category-analyse-technische-sauberkeit tag-analysen-mit-akkreditierung tag-bauteilsauberkeit tag-fremdpartikel tag-iso-16232 tag-partikelanalyse tag-partikelscanner tag-prueflabor tag-rasterelektronenmikroskopie tag-reinheit tag-restschmutz tag-restschmutzanalyse tag-sauberkeitsanalyse tag-sauberkeitspruefung tag-sem-edx tag-technische-sauberkeit tag-vda-19\" role=\"listitem\">\n\t\t\t\t<a class=\"elementor-post__thumbnail__link\" href=\"https:\/\/www.rjl-microanalytic.de\/en\/treffen-sie-uns-auf-der-16-fachtagung-technische-sauberkeit-in-heidenheim\/\" tabindex=\"-1\" >\n\t\t\t<div class=\"elementor-post__thumbnail\"><img decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/Fachtagung_Technische_Sauberkeit_2026-150x150.png\" class=\"attachment-thumbnail size-thumbnail wp-image-15961\" alt=\"\" srcset=\"https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/Fachtagung_Technische_Sauberkeit_2026-150x150.png 150w, https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/Fachtagung_Technische_Sauberkeit_2026-13x12.png 13w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><\/div>\n\t\t<\/a>\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h3 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/www.rjl-microanalytic.de\/en\/treffen-sie-uns-auf-der-16-fachtagung-technische-sauberkeit-in-heidenheim\/\" >\n\t\t\t\tTreffen Sie uns auf der 16. Fachtagung Technische Sauberkeit in Heidenheim\t\t\t<\/a>\n\t\t<\/h3>\n\t\t\t\t<\/div>\n\t\t\t\t<\/article>\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-15930 post type-post status-publish format-standard has-post-thumbnail hentry category-innovative-analytik category-analyse-technische-sauberkeit category-elektronenmikroskopie-sem-edx tag-adblue tag-fremdpartikel tag-getrieboel tag-hydraulikoel tag-kraftstoffe tag-kuehlmittel tag-motoroel tag-partikelanalyse tag-prueflabor tag-reinstwasser tag-restschmutz tag-restschmutzanalyse tag-roentgenelementanalyse tag-sauberkeitsanalyse tag-sauberkeitspruefung tag-schmiermittel tag-sem-edx tag-verunreinigungen\" role=\"listitem\">\n\t\t\t\t<a class=\"elementor-post__thumbnail__link\" href=\"https:\/\/www.rjl-microanalytic.de\/en\/so-gehen-sie-der-herkunft-von-verunreinigungen-in-fluessigkeiten-auf-den-grund\/\" tabindex=\"-1\" >\n\t\t\t<div class=\"elementor-post__thumbnail\"><img decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/Liquid-with-particles-and-bubbles-150x150.jpg\" class=\"attachment-thumbnail size-thumbnail wp-image-15935\" alt=\"\" srcset=\"https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/Liquid-with-particles-and-bubbles-150x150.jpg 150w, https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/Liquid-with-particles-and-bubbles-300x300.jpg 300w, https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/Liquid-with-particles-and-bubbles-1024x1024.jpg 1024w, https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/Liquid-with-particles-and-bubbles-768x768.jpg 768w, https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/Liquid-with-particles-and-bubbles-1536x1536.jpg 1536w, https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/Liquid-with-particles-and-bubbles-2048x2048.jpg 2048w, https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/Liquid-with-particles-and-bubbles-12x12.jpg 12w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><\/div>\n\t\t<\/a>\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h3 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/www.rjl-microanalytic.de\/en\/so-gehen-sie-der-herkunft-von-verunreinigungen-in-fluessigkeiten-auf-den-grund\/\" >\n\t\t\t\tSo gehen Sie der Herkunft von Verunreinigungen in Fl\u00fcssigkeiten auf den Grund\t\t\t<\/a>\n\t\t<\/h3>\n\t\t\t\t<\/div>\n\t\t\t\t<\/article>\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-15903 post type-post status-publish format-standard has-post-thumbnail hentry category-innovative-analytik category-analyse-technische-sauberkeit category-elektronenmikroskopie-sem-edx tag-arzneimittel tag-fremdpartikel tag-partikelanalyse tag-prueflabor tag-restschmutz tag-restschmutzanalyse tag-roentgenelementanalyse tag-sauberkeitsanalyse tag-sauberkeitspruefung tag-sem-edx\" role=\"listitem\">\n\t\t\t\t<a class=\"elementor-post__thumbnail__link\" href=\"https:\/\/www.rjl-microanalytic.de\/en\/materialbestimmung-von-fremdpartikeln-in-zytostatika-und-anderen-fluessigen-arzneimitteln\/\" tabindex=\"-1\" >\n\t\t\t<div class=\"elementor-post__thumbnail\"><img loading=\"lazy\" decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/Foreign_Particle_Zinc_Agglomerate-150x150.png\" class=\"attachment-thumbnail size-thumbnail wp-image-15909\" alt=\"\" srcset=\"https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/Foreign_Particle_Zinc_Agglomerate-150x150.png 150w, https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/Foreign_Particle_Zinc_Agglomerate-300x300.png 300w, https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/Foreign_Particle_Zinc_Agglomerate-768x768.png 768w, https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/Foreign_Particle_Zinc_Agglomerate-12x12.png 12w, https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/Foreign_Particle_Zinc_Agglomerate.png 1024w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><\/div>\n\t\t<\/a>\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h3 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/www.rjl-microanalytic.de\/en\/materialbestimmung-von-fremdpartikeln-in-zytostatika-und-anderen-fluessigen-arzneimitteln\/\" >\n\t\t\t\tMaterialbestimmung von Fremdpartikeln in Zytostatika und anderen fl\u00fcssigen Arzneimitteln\t\t\t<\/a>\n\t\t<\/h3>\n\t\t\t\t<\/div>\n\t\t\t\t<\/article>\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-15757 post type-post status-publish format-standard has-post-thumbnail hentry category-innovative-analytik category-analyse-technische-sauberkeit category-elektronenmikroskopie-sem-edx tag-bauteilsauberkeit tag-iso-16232 tag-partikelanalyse tag-prueflabor tag-restschmutz tag-restschmutzanalyse tag-roentgenelementanalyse tag-sauberkeitsanalyse tag-sauberkeitspruefung tag-sem-edx tag-technische-sauberkeit tag-vda-19\" role=\"listitem\">\n\t\t\t\t<a class=\"elementor-post__thumbnail__link\" href=\"https:\/\/www.rjl-microanalytic.de\/en\/ultra-schnelle-sem-edx-analyse-von-restschmutzpartikeln-ab-100-%c2%b5m-mit-dem-particlex\/\" tabindex=\"-1\" >\n\t\t\t<div class=\"elementor-post__thumbnail\"><img loading=\"lazy\" decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/Filter-Analysis-larger-100-microns-150x150.jpg\" class=\"attachment-thumbnail size-thumbnail wp-image-15806\" alt=\"\" srcset=\"https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/Filter-Analysis-larger-100-microns-150x150.jpg 150w, https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/Filter-Analysis-larger-100-microns-300x300.jpg 300w, https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/Filter-Analysis-larger-100-microns-1024x1024.jpg 1024w, https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/Filter-Analysis-larger-100-microns-768x768.jpg 768w, https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/Filter-Analysis-larger-100-microns-1536x1536.jpg 1536w, https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/Filter-Analysis-larger-100-microns-2048x2048.jpg 2048w, https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/Filter-Analysis-larger-100-microns-12x12.jpg 12w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><\/div>\n\t\t<\/a>\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h3 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/www.rjl-microanalytic.de\/en\/ultra-schnelle-sem-edx-analyse-von-restschmutzpartikeln-ab-100-%c2%b5m-mit-dem-particlex\/\" >\n\t\t\t\tUltra-Schnelle SEM-EDX Analyse von Restschmutzpartikeln ab 100 \u00b5m mit dem ParticleX\t\t\t<\/a>\n\t\t<\/h3>\n\t\t\t\t<\/div>\n\t\t\t\t<\/article>\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-15697 post type-post status-publish format-standard has-post-thumbnail hentry category-rjl-firmennachrichten category-innovative-analytik category-analyse-technische-sauberkeit category-elektronenmikroskopie-sem-edx tag-analysen-mit-akkreditierung tag-bauteilsauberkeit tag-fremdpartikel tag-iso-16232 tag-partikelanalyse tag-prueflabor tag-rasterelektronenmikroskopie tag-reinheit tag-restschmutz tag-restschmutzanalyse tag-sauberkeitsanalyse tag-sauberkeitspruefung tag-sem-edx tag-technische-sauberkeit tag-vda-19\" role=\"listitem\">\n\t\t\t\t<a class=\"elementor-post__thumbnail__link\" href=\"https:\/\/www.rjl-microanalytic.de\/en\/laborkapazitaet-fuer-sem-edx-partikelanalytik-erfolgreich-getestet\/\" tabindex=\"-1\" >\n\t\t\t<div class=\"elementor-post__thumbnail\"><img loading=\"lazy\" decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/48_filter_membranes_for_SEM-EDX_particle_analysis-150x150.jpg\" class=\"attachment-thumbnail size-thumbnail wp-image-15696\" alt=\"\" srcset=\"https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/48_filter_membranes_for_SEM-EDX_particle_analysis-150x150.jpg 150w, https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/48_filter_membranes_for_SEM-EDX_particle_analysis-11x12.jpg 11w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><\/div>\n\t\t<\/a>\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h3 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/www.rjl-microanalytic.de\/en\/laborkapazitaet-fuer-sem-edx-partikelanalytik-erfolgreich-getestet\/\" >\n\t\t\t\tLaborkapazit\u00e4t f\u00fcr SEM-EDX Partikelanalytik erfolgreich getestet\t\t\t<\/a>\n\t\t<\/h3>\n\t\t\t\t<\/div>\n\t\t\t\t<\/article>\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-15556 post type-post status-publish format-standard has-post-thumbnail hentry category-rjl-firmennachrichten category-innovative-analytik category-analyse-technische-sauberkeit tag-analysen-mit-akkreditierung tag-bauteilsauberkeit tag-fremdpartikel tag-iso-16232 tag-partikelanalyse tag-partikelscanner tag-prueflabor tag-rasterelektronenmikroskopie tag-reinheit tag-restschmutz tag-restschmutzanalyse tag-sauberkeitsanalyse tag-sauberkeitspruefung tag-sem-edx tag-technische-sauberkeit tag-vda-19\" role=\"listitem\">\n\t\t\t\t<a class=\"elementor-post__thumbnail__link\" href=\"https:\/\/www.rjl-microanalytic.de\/en\/wir-vergeben-kostenlose-eintrittskarten-fuer-die-parts2clean-2025\/\" tabindex=\"-1\" >\n\t\t\t<div class=\"elementor-post__thumbnail\"><img loading=\"lazy\" decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/parts2clean-wir-sind-dabei-150x150.jpg\" class=\"attachment-thumbnail size-thumbnail wp-image-15555\" alt=\"\" srcset=\"https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/parts2clean-wir-sind-dabei-150x150.jpg 150w, https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/parts2clean-wir-sind-dabei-300x300.jpg 300w, https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/parts2clean-wir-sind-dabei-1024x1024.jpg 1024w, https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/parts2clean-wir-sind-dabei-768x768.jpg 768w, https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/parts2clean-wir-sind-dabei-12x12.jpg 12w, https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/parts2clean-wir-sind-dabei.jpg 1080w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><\/div>\n\t\t<\/a>\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h3 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/www.rjl-microanalytic.de\/en\/wir-vergeben-kostenlose-eintrittskarten-fuer-die-parts2clean-2025\/\" >\n\t\t\t\tWir vergeben kostenlose Eintrittskarten f\u00fcr die Parts2Clean 2025\t\t\t<\/a>\n\t\t<\/h3>\n\t\t\t\t<\/div>\n\t\t\t\t<\/article>\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-15471 post type-post status-publish format-standard has-post-thumbnail hentry category-innovative-analytik category-analyse-technische-sauberkeit category-elektronenmikroskopie-sem-edx tag-bauteilsauberkeit tag-iso-16232 tag-partikelanalyse tag-prueflabor tag-restschmutz tag-restschmutzanalyse tag-roentgenelementanalyse tag-sauberkeitsanalyse tag-sauberkeitspruefung tag-sem-edx tag-technische-sauberkeit tag-vda-19\" role=\"listitem\">\n\t\t\t\t<a class=\"elementor-post__thumbnail__link\" href=\"https:\/\/www.rjl-microanalytic.de\/en\/fremdpartikel-in-arzneimittelflaschen\/\" tabindex=\"-1\" >\n\t\t\t<div class=\"elementor-post__thumbnail\"><img loading=\"lazy\" decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/Syringe-in-Vial-6-150x150.jpg\" class=\"attachment-thumbnail size-thumbnail wp-image-15875\" alt=\"\" \/><\/div>\n\t\t<\/a>\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h3 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/www.rjl-microanalytic.de\/en\/fremdpartikel-in-arzneimittelflaschen\/\" >\n\t\t\t\tFremdpartikel in Arzneimittelflaschen\t\t\t<\/a>\n\t\t<\/h3>\n\t\t\t\t<\/div>\n\t\t\t\t<\/article>\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-14641 post type-post status-publish format-standard has-post-thumbnail hentry category-innovative-analytik category-analyse-technische-sauberkeit tag-analysen-mit-akkreditierung tag-bauteilsauberkeit tag-fehleranalyse-bei-medizinprodukten tag-fremdpartikel tag-iso-16232 tag-partikelanalyse tag-partikelscanner tag-pharmaindustrie tag-restschmutz tag-restschmutzanalyse tag-sauberkeitsanalyse tag-sauberkeitspruefung tag-technische-sauberkeit tag-vda-19 tag-vdi-2083-blatt-21\" role=\"listitem\">\n\t\t\t\t<a class=\"elementor-post__thumbnail__link\" href=\"https:\/\/www.rjl-microanalytic.de\/en\/richtige-probenverpackung-fuer-die-sauberkeitspruefung-von-hochreinen-produkten\/\" tabindex=\"-1\" >\n\t\t\t<div class=\"elementor-post__thumbnail\"><img loading=\"lazy\" decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/delicate_sample_cleanliness_testing-150x150.jpg\" class=\"attachment-thumbnail size-thumbnail wp-image-14640\" alt=\"\" \/><\/div>\n\t\t<\/a>\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h3 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/www.rjl-microanalytic.de\/en\/richtige-probenverpackung-fuer-die-sauberkeitspruefung-von-hochreinen-produkten\/\" >\n\t\t\t\tRichtige Probenverpackung f\u00fcr die Sauberkeitspr\u00fcfung von hochreinen Produkten\t\t\t<\/a>\n\t\t<\/h3>\n\t\t\t\t<\/div>\n\t\t\t\t<\/article>\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-13384 post type-post status-publish format-standard has-post-thumbnail hentry category-innovative-analytik category-analyse-technische-sauberkeit category-elektronenmikroskopie-sem-edx tag-bauteilsauberkeit tag-iso-16232 tag-partikelanalyse tag-prueflabor tag-restschmutz tag-restschmutzanalyse tag-roentgenelementanalyse tag-sauberkeitsanalyse tag-sauberkeitspruefung tag-sem-edx tag-technische-sauberkeit tag-vda-19\" role=\"listitem\">\n\t\t\t\t<a class=\"elementor-post__thumbnail__link\" href=\"https:\/\/www.rjl-microanalytic.de\/en\/particle-browser-ein-neues-werkzeug-zur-nachkontrolle-der-sem-edx-partikelanalyse\/\" tabindex=\"-1\" >\n\t\t\t<div class=\"elementor-post__thumbnail\"><img loading=\"lazy\" decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/Particle-Browser-Corundum-With-Spectrum-150x150.jpg\" class=\"attachment-thumbnail size-thumbnail wp-image-13382\" alt=\"\" \/><\/div>\n\t\t<\/a>\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h3 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/www.rjl-microanalytic.de\/en\/particle-browser-ein-neues-werkzeug-zur-nachkontrolle-der-sem-edx-partikelanalyse\/\" >\n\t\t\t\tParticle Browser: Ein Neues Werkzeug zur Nachkontrolle der SEM-EDX Partikelanalyse\t\t\t<\/a>\n\t\t<\/h3>\n\t\t\t\t<\/div>\n\t\t\t\t<\/article>\n\t\t\t\t<\/div>\n\t\t\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<h3 id=\"elementor-tab-title-1593\" class=\"elementor-tab-title\" data-tab=\"3\" role=\"button\" aria-controls=\"elementor-tab-content-1593\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-right\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><i class=\"fas fa-chevron-down\"><\/i><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><i class=\"elementor-toggle-icon-opened fas fa-chevron-up\"><\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Ger\u00e4te & Produkte<\/a>\n\t\t\t\t\t<\/h3>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-1593\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"3\" role=\"region\" aria-labelledby=\"elementor-tab-title-1593\"><p>\t\t<div data-elementor-type=\"section\" data-elementor-id=\"6258\" class=\"elementor elementor-6258\" data-elementor-post-type=\"elementor_library\">\n\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-3382209e elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"3382209e\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-6fdfdabd\" data-id=\"6fdfdabd\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-2789ab80 elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"2789ab80\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"\/instrumente\/microquick-partikelscanner-technische-sauberkeit\/\">\n\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-info-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">MicroQuick-Partikelscanner<\/span>\n\t\t\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"\/instrumente\/aspex-explorer-sem-edx-partikelanalyser\/\">\n\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-info-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">SEM-EDX-Partikelanalyser<\/span>\n\t\t\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"\/restschmutzanalyse-technische-sauberkeit-vda-19-iso-16232\/microex-partikelextraktion\/\">\n\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-info-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">MicroEx-Extraktionsanlage<\/span>\n\t\t\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"\/restschmutzanalyse-technische-sauberkeit-vda-19-iso-16232\/microproducts-partikelfallen-partikelstempel\/\">\n\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-info-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Partikelfallen, Stempel, etc.<\/span>\n\t\t\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"\/restschmutzanalyse-technische-sauberkeit-vda-19-iso-16232\/microquick-microproducts-internationale-distribution\/\">\n\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-info-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"> Distribution weltweit<\/span>\n\t\t\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>TESTED ACCORDING TO STANDARDS Standards &amp; testing regulations according to which we work for our customers VDA-19.1 &amp; ISO-16232 Basic standards for cleanliness analysis When analyzing technical cleanliness<\/p>","protected":false},"author":1,"featured_media":0,"parent":1171,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1188","page","type-page","status-publish","hentry"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 4.9.10 - aioseo.com -->\n\t<meta name=\"description\" content=\"Wer eine Sauberkeitspr\u00fcfung von Proben durchf\u00fchren l\u00e4sst, ist auf eine zuverl\u00e4ssige Untersuchung und genaue Bestimmung und Darstellung der enthaltenen Partikel angewiesen. Mit unserem Particle Browser bieten wir Ihnen eine Software zur Nachkontrolle und Revision an, um Analyseergebnisse zu verifizieren bzw. m\u00f6gliche Messfehler zu erkennen und zu korrigieren.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/www.rjl-microanalytic.de\/en\/particle-browser-ein-neues-werkzeug-zur-nachkontrolle-der-sem-edx-partikelanalyse\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 4.9.10\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"RJL Micro &amp; Analytic | Analysenservice &amp; Instrument aus einer Hand\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Particle Browser: Ein Neues Werkzeug zur Nachkontrolle der SEM-EDX Partikelanalyse | RJL Micro &amp; Analytic\" \/>\n\t\t<meta property=\"og:description\" content=\"Wer eine Sauberkeitspr\u00fcfung von Proben durchf\u00fchren l\u00e4sst, ist auf eine zuverl\u00e4ssige Untersuchung und genaue Bestimmung und Darstellung der enthaltenen Partikel angewiesen. Mit unserem Particle Browser bieten wir Ihnen eine Software zur Nachkontrolle und Revision an, um Analyseergebnisse zu verifizieren bzw. m\u00f6gliche Messfehler zu erkennen und zu korrigieren.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/www.rjl-microanalytic.de\/en\/particle-browser-ein-neues-werkzeug-zur-nachkontrolle-der-sem-edx-partikelanalyse\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/2021\/07\/RJLMA_firmenlogo.png\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/2021\/07\/RJLMA_firmenlogo.png\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2024-06-26T09:45:18+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2024-07-08T14:13:19+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Particle Browser: Ein Neues Werkzeug zur Nachkontrolle der SEM-EDX Partikelanalyse | RJL Micro &amp; Analytic\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Wer eine Sauberkeitspr\u00fcfung von Proben durchf\u00fchren l\u00e4sst, ist auf eine zuverl\u00e4ssige Untersuchung und genaue Bestimmung und Darstellung der enthaltenen Partikel angewiesen. Mit unserem Particle Browser bieten wir Ihnen eine Software zur Nachkontrolle und Revision an, um Analyseergebnisse zu verifizieren bzw. m\u00f6gliche Messfehler zu erkennen und zu korrigieren.\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/2021\/07\/RJLMA_firmenlogo.png\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/www.rjl-microanalytic.de\\\/en\\\/particle-browser-ein-neues-werkzeug-zur-nachkontrolle-der-sem-edx-partikelanalyse\\\/#blogposting\",\"name\":\"Particle Browser: Ein Neues Werkzeug zur Nachkontrolle der SEM-EDX Partikelanalyse | RJL Micro & Analytic\",\"headline\":\"Particle Browser: Ein Neues Werkzeug zur Nachkontrolle der SEM-EDX Partikelanalyse\",\"author\":{\"@id\":\"https:\\\/\\\/www.rjl-microanalytic.de\\\/en\\\/author\\\/rjladmin\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/www.rjl-microanalytic.de\\\/en\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.rjl-microanalytic.de\\\/wp-content\\\/uploads\\\/Particle-Browser-Corundum-With-Spectrum.jpg\",\"width\":1896,\"height\":970},\"datePublished\":\"2024-06-26T11:45:18+02:00\",\"dateModified\":\"2024-07-08T16:13:19+02:00\",\"inLanguage\":\"en-US\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.rjl-microanalytic.de\\\/en\\\/particle-browser-ein-neues-werkzeug-zur-nachkontrolle-der-sem-edx-partikelanalyse\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.rjl-microanalytic.de\\\/en\\\/particle-browser-ein-neues-werkzeug-zur-nachkontrolle-der-sem-edx-partikelanalyse\\\/#webpage\"},\"articleSection\":\"Innovative Analytik, Sauberkeitsanalyse, SEM-EDX, Bauteilsauberkeit, ISO-16232, Partikelanalyse, Pr\\u00fcflabor, Restschmutz, Restschmutzanalyse, R\\u00f6ntgenelementanalyse, Sauberkeitsanalyse, Sauberkeitspr\\u00fcfung, SEM-EDX, Technische Sauberkeit, VDA-19\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.rjl-microanalytic.de\\\/en\\\/particle-browser-ein-neues-werkzeug-zur-nachkontrolle-der-sem-edx-partikelanalyse\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.rjl-microanalytic.de\\\/en#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.rjl-microanalytic.de\\\/en\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.rjl-microanalytic.de\\\/en\\\/restschmutzanalyse-technische-sauberkeit-vda-19-iso-16232\\\/#listItem\",\"name\":\"Restschmutzanalyse VDA-19 &#038; ISO-16232\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.rjl-microanalytic.de\\\/en\\\/restschmutzanalyse-technische-sauberkeit-vda-19-iso-16232\\\/#listItem\",\"position\":2,\"name\":\"Restschmutzanalyse VDA-19 &#038; ISO-16232\",\"item\":\"https:\\\/\\\/www.rjl-microanalytic.de\\\/en\\\/restschmutzanalyse-technische-sauberkeit-vda-19-iso-16232\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.rjl-microanalytic.de\\\/en\\\/restschmutzanalyse-technische-sauberkeit-vda-19-iso-16232\\\/pruefnormen-pruefvorschriften-restschmutz-technische-sauberkeit\\\/#listItem\",\"name\":\"Pr\\u00fcfnormen der Technischen Sauberkeit\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.rjl-microanalytic.de\\\/en#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.rjl-microanalytic.de\\\/en\\\/restschmutzanalyse-technische-sauberkeit-vda-19-iso-16232\\\/pruefnormen-pruefvorschriften-restschmutz-technische-sauberkeit\\\/#listItem\",\"position\":3,\"name\":\"Pr\\u00fcfnormen der Technischen Sauberkeit\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.rjl-microanalytic.de\\\/en\\\/restschmutzanalyse-technische-sauberkeit-vda-19-iso-16232\\\/#listItem\",\"name\":\"Restschmutzanalyse VDA-19 &#038; ISO-16232\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.rjl-microanalytic.de\\\/en\\\/#organization\",\"name\":\"RJL Micro & Analytic\",\"description\":\"Analysenservice & Instrument aus einer Hand\",\"url\":\"https:\\\/\\\/www.rjl-microanalytic.de\\\/en\\\/\",\"telephone\":\"+497251367900\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/new.rjl-microanalytic.de\\\/wp-content\\\/uploads\\\/2021\\\/07\\\/RJLMA.png\",\"@id\":\"https:\\\/\\\/www.rjl-microanalytic.de\\\/en\\\/particle-browser-ein-neues-werkzeug-zur-nachkontrolle-der-sem-edx-partikelanalyse\\\/#organizationLogo\"},\"image\":{\"@id\":\"https:\\\/\\\/www.rjl-microanalytic.de\\\/en\\\/particle-browser-ein-neues-werkzeug-zur-nachkontrolle-der-sem-edx-partikelanalyse\\\/#organizationLogo\"},\"sameAs\":[\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCyub0dLFT-i6Pn9u1k4R3uw\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/rjl-micro-&-analytic-gmbh\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.rjl-microanalytic.de\\\/en\\\/author\\\/rjladmin\\\/#author\",\"url\":\"https:\\\/\\\/www.rjl-microanalytic.de\\\/en\\\/author\\\/rjladmin\\\/\",\"name\":\"Markus J. Heneka\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.rjl-microanalytic.de\\\/en\\\/particle-browser-ein-neues-werkzeug-zur-nachkontrolle-der-sem-edx-partikelanalyse\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ce3f7afbd2023e5aafd10f10873dfa8e8d6a77030f1dd14f321f8ed17693454e?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"Markus J. Heneka\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.rjl-microanalytic.de\\\/en\\\/particle-browser-ein-neues-werkzeug-zur-nachkontrolle-der-sem-edx-partikelanalyse\\\/#webpage\",\"url\":\"https:\\\/\\\/www.rjl-microanalytic.de\\\/en\\\/particle-browser-ein-neues-werkzeug-zur-nachkontrolle-der-sem-edx-partikelanalyse\\\/\",\"name\":\"Particle Browser: Ein Neues Werkzeug zur Nachkontrolle der SEM-EDX Partikelanalyse | RJL Micro & Analytic\",\"description\":\"Wer eine Sauberkeitspr\\u00fcfung von Proben durchf\\u00fchren l\\u00e4sst, ist auf eine zuverl\\u00e4ssige Untersuchung und genaue Bestimmung und Darstellung der enthaltenen Partikel angewiesen. Mit unserem Particle Browser bieten wir Ihnen eine Software zur Nachkontrolle und Revision an, um Analyseergebnisse zu verifizieren bzw. m\\u00f6gliche Messfehler zu erkennen und zu korrigieren.\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.rjl-microanalytic.de\\\/en\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.rjl-microanalytic.de\\\/en\\\/particle-browser-ein-neues-werkzeug-zur-nachkontrolle-der-sem-edx-partikelanalyse\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/www.rjl-microanalytic.de\\\/en\\\/author\\\/rjladmin\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/www.rjl-microanalytic.de\\\/en\\\/author\\\/rjladmin\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.rjl-microanalytic.de\\\/wp-content\\\/uploads\\\/Particle-Browser-Corundum-With-Spectrum.jpg\",\"@id\":\"https:\\\/\\\/www.rjl-microanalytic.de\\\/en\\\/particle-browser-ein-neues-werkzeug-zur-nachkontrolle-der-sem-edx-partikelanalyse\\\/#mainImage\",\"width\":1896,\"height\":970},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.rjl-microanalytic.de\\\/en\\\/particle-browser-ein-neues-werkzeug-zur-nachkontrolle-der-sem-edx-partikelanalyse\\\/#mainImage\"},\"datePublished\":\"2024-06-26T11:45:18+02:00\",\"dateModified\":\"2024-07-08T16:13:19+02:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.rjl-microanalytic.de\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.rjl-microanalytic.de\\\/en\\\/\",\"name\":\"RJL Micro & Analytic\",\"alternateName\":\"RJLMA\",\"description\":\"Analysenservice & Instrument aus einer Hand\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.rjl-microanalytic.de\\\/en\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"Particle Browser: A new tool for verifying SEM-EDX particle analysis | RJL Micro &amp; Analytic","description":"Anyone who has samples tested for cleanliness relies on reliable testing and precise determination and representation of the particles contained. With our Particle Browser, we offer you software for follow-up checks and revisions to verify analysis results and to identify and correct possible measurement errors.","canonical_url":"https:\/\/www.rjl-microanalytic.de\/en\/particle-browser-ein-neues-werkzeug-zur-nachkontrolle-der-sem-edx-partikelanalyse\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/www.rjl-microanalytic.de\/en\/particle-browser-ein-neues-werkzeug-zur-nachkontrolle-der-sem-edx-partikelanalyse\/#blogposting","name":"Particle Browser: Ein Neues Werkzeug zur Nachkontrolle der SEM-EDX Partikelanalyse | RJL Micro & Analytic","headline":"Particle Browser: Ein Neues Werkzeug zur Nachkontrolle der SEM-EDX Partikelanalyse","author":{"@id":"https:\/\/www.rjl-microanalytic.de\/en\/author\/rjladmin\/#author"},"publisher":{"@id":"https:\/\/www.rjl-microanalytic.de\/en\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/Particle-Browser-Corundum-With-Spectrum.jpg","width":1896,"height":970},"datePublished":"2024-06-26T11:45:18+02:00","dateModified":"2024-07-08T16:13:19+02:00","inLanguage":"en-US","mainEntityOfPage":{"@id":"https:\/\/www.rjl-microanalytic.de\/en\/particle-browser-ein-neues-werkzeug-zur-nachkontrolle-der-sem-edx-partikelanalyse\/#webpage"},"isPartOf":{"@id":"https:\/\/www.rjl-microanalytic.de\/en\/particle-browser-ein-neues-werkzeug-zur-nachkontrolle-der-sem-edx-partikelanalyse\/#webpage"},"articleSection":"Innovative Analytik, Sauberkeitsanalyse, SEM-EDX, Bauteilsauberkeit, ISO-16232, Partikelanalyse, Pr\u00fcflabor, Restschmutz, Restschmutzanalyse, R\u00f6ntgenelementanalyse, Sauberkeitsanalyse, Sauberkeitspr\u00fcfung, SEM-EDX, Technische Sauberkeit, VDA-19"},{"@type":"BreadcrumbList","@id":"https:\/\/www.rjl-microanalytic.de\/en\/particle-browser-ein-neues-werkzeug-zur-nachkontrolle-der-sem-edx-partikelanalyse\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/www.rjl-microanalytic.de\/en#listItem","position":1,"name":"Home","item":"https:\/\/www.rjl-microanalytic.de\/en","nextItem":{"@type":"ListItem","@id":"https:\/\/www.rjl-microanalytic.de\/en\/restschmutzanalyse-technische-sauberkeit-vda-19-iso-16232\/#listItem","name":"Restschmutzanalyse VDA-19 &#038; ISO-16232"}},{"@type":"ListItem","@id":"https:\/\/www.rjl-microanalytic.de\/en\/restschmutzanalyse-technische-sauberkeit-vda-19-iso-16232\/#listItem","position":2,"name":"Restschmutzanalyse VDA-19 &#038; ISO-16232","item":"https:\/\/www.rjl-microanalytic.de\/en\/restschmutzanalyse-technische-sauberkeit-vda-19-iso-16232\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.rjl-microanalytic.de\/en\/restschmutzanalyse-technische-sauberkeit-vda-19-iso-16232\/pruefnormen-pruefvorschriften-restschmutz-technische-sauberkeit\/#listItem","name":"Pr\u00fcfnormen der Technischen Sauberkeit"},"previousItem":{"@type":"ListItem","@id":"https:\/\/www.rjl-microanalytic.de\/en#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/www.rjl-microanalytic.de\/en\/restschmutzanalyse-technische-sauberkeit-vda-19-iso-16232\/pruefnormen-pruefvorschriften-restschmutz-technische-sauberkeit\/#listItem","position":3,"name":"Pr\u00fcfnormen der Technischen Sauberkeit","previousItem":{"@type":"ListItem","@id":"https:\/\/www.rjl-microanalytic.de\/en\/restschmutzanalyse-technische-sauberkeit-vda-19-iso-16232\/#listItem","name":"Restschmutzanalyse VDA-19 &#038; ISO-16232"}}]},{"@type":"Organization","@id":"https:\/\/www.rjl-microanalytic.de\/en\/#organization","name":"RJL Micro & Analytic","description":"Analysenservice & Instrument aus einer Hand","url":"https:\/\/www.rjl-microanalytic.de\/en\/","telephone":"+497251367900","logo":{"@type":"ImageObject","url":"https:\/\/new.rjl-microanalytic.de\/wp-content\/uploads\/2021\/07\/RJLMA.png","@id":"https:\/\/www.rjl-microanalytic.de\/en\/particle-browser-ein-neues-werkzeug-zur-nachkontrolle-der-sem-edx-partikelanalyse\/#organizationLogo"},"image":{"@id":"https:\/\/www.rjl-microanalytic.de\/en\/particle-browser-ein-neues-werkzeug-zur-nachkontrolle-der-sem-edx-partikelanalyse\/#organizationLogo"},"sameAs":["https:\/\/www.youtube.com\/channel\/UCyub0dLFT-i6Pn9u1k4R3uw","https:\/\/www.linkedin.com\/company\/rjl-micro-&-analytic-gmbh\/"]},{"@type":"Person","@id":"https:\/\/www.rjl-microanalytic.de\/en\/author\/rjladmin\/#author","url":"https:\/\/www.rjl-microanalytic.de\/en\/author\/rjladmin\/","name":"Markus J. Heneka","image":{"@type":"ImageObject","@id":"https:\/\/www.rjl-microanalytic.de\/en\/particle-browser-ein-neues-werkzeug-zur-nachkontrolle-der-sem-edx-partikelanalyse\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/ce3f7afbd2023e5aafd10f10873dfa8e8d6a77030f1dd14f321f8ed17693454e?s=96&d=mm&r=g","width":96,"height":96,"caption":"Markus J. Heneka"}},{"@type":"WebPage","@id":"https:\/\/www.rjl-microanalytic.de\/en\/particle-browser-ein-neues-werkzeug-zur-nachkontrolle-der-sem-edx-partikelanalyse\/#webpage","url":"https:\/\/www.rjl-microanalytic.de\/en\/particle-browser-ein-neues-werkzeug-zur-nachkontrolle-der-sem-edx-partikelanalyse\/","name":"Particle Browser: Ein Neues Werkzeug zur Nachkontrolle der SEM-EDX Partikelanalyse | RJL Micro & Analytic","description":"Wer eine Sauberkeitspr\u00fcfung von Proben durchf\u00fchren l\u00e4sst, ist auf eine zuverl\u00e4ssige Untersuchung und genaue Bestimmung und Darstellung der enthaltenen Partikel angewiesen. Mit unserem Particle Browser bieten wir Ihnen eine Software zur Nachkontrolle und Revision an, um Analyseergebnisse zu verifizieren bzw. m\u00f6gliche Messfehler zu erkennen und zu korrigieren.","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/www.rjl-microanalytic.de\/en\/#website"},"breadcrumb":{"@id":"https:\/\/www.rjl-microanalytic.de\/en\/particle-browser-ein-neues-werkzeug-zur-nachkontrolle-der-sem-edx-partikelanalyse\/#breadcrumblist"},"author":{"@id":"https:\/\/www.rjl-microanalytic.de\/en\/author\/rjladmin\/#author"},"creator":{"@id":"https:\/\/www.rjl-microanalytic.de\/en\/author\/rjladmin\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/Particle-Browser-Corundum-With-Spectrum.jpg","@id":"https:\/\/www.rjl-microanalytic.de\/en\/particle-browser-ein-neues-werkzeug-zur-nachkontrolle-der-sem-edx-partikelanalyse\/#mainImage","width":1896,"height":970},"primaryImageOfPage":{"@id":"https:\/\/www.rjl-microanalytic.de\/en\/particle-browser-ein-neues-werkzeug-zur-nachkontrolle-der-sem-edx-partikelanalyse\/#mainImage"},"datePublished":"2024-06-26T11:45:18+02:00","dateModified":"2024-07-08T16:13:19+02:00"},{"@type":"WebSite","@id":"https:\/\/www.rjl-microanalytic.de\/en\/#website","url":"https:\/\/www.rjl-microanalytic.de\/en\/","name":"RJL Micro & Analytic","alternateName":"RJLMA","description":"Analysenservice & Instrument aus einer Hand","inLanguage":"en-US","publisher":{"@id":"https:\/\/www.rjl-microanalytic.de\/en\/#organization"}}]},"og:locale":"en_US","og:site_name":"RJL Micro &amp; Analytic | Analysenservice &amp; Instrument aus einer Hand","og:type":"article","og:title":"Particle Browser: Ein Neues Werkzeug zur Nachkontrolle der SEM-EDX Partikelanalyse | RJL Micro &amp; Analytic","og:description":"Wer eine Sauberkeitspr\u00fcfung von Proben durchf\u00fchren l\u00e4sst, ist auf eine zuverl\u00e4ssige Untersuchung und genaue Bestimmung und Darstellung der enthaltenen Partikel angewiesen. Mit unserem Particle Browser bieten wir Ihnen eine Software zur Nachkontrolle und Revision an, um Analyseergebnisse zu verifizieren bzw. m\u00f6gliche Messfehler zu erkennen und zu korrigieren.","og:url":"https:\/\/www.rjl-microanalytic.de\/en\/particle-browser-ein-neues-werkzeug-zur-nachkontrolle-der-sem-edx-partikelanalyse\/","og:image":"https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/2021\/07\/RJLMA_firmenlogo.png","og:image:secure_url":"https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/2021\/07\/RJLMA_firmenlogo.png","article:published_time":"2024-06-26T09:45:18+00:00","article:modified_time":"2024-07-08T14:13:19+00:00","twitter:card":"summary","twitter:title":"Particle Browser: Ein Neues Werkzeug zur Nachkontrolle der SEM-EDX Partikelanalyse | RJL Micro &amp; Analytic","twitter:description":"Wer eine Sauberkeitspr\u00fcfung von Proben durchf\u00fchren l\u00e4sst, ist auf eine zuverl\u00e4ssige Untersuchung und genaue Bestimmung und Darstellung der enthaltenen Partikel angewiesen. Mit unserem Particle Browser bieten wir Ihnen eine Software zur Nachkontrolle und Revision an, um Analyseergebnisse zu verifizieren bzw. m\u00f6gliche Messfehler zu erkennen und zu korrigieren.","twitter:image":"https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/2021\/07\/RJLMA_firmenlogo.png"},"aioseo_meta_data":{"post_id":"1188","title":null,"description":"Liste der Pr\u00fcfnormen f\u00fcr die Analyse der Technischen Sauberkeit, unsere Verfahren im Bereich der VDA-19.1 (2015) und ISO-16232 (2018)","keywords":[],"keyphrases":{"focus":{"keyphrase":"ISO-16232","score":69,"analysis":{"keyphraseInTitle":{"score":3,"maxScore":9,"error":1},"keyphraseInDescription":{"score":9,"maxScore":9,"error":0},"keyphraseLength":{"score":9,"maxScore":9,"error":0,"length":1},"keyphraseInURL":{"score":5,"maxScore":5,"error":0},"keyphraseInIntroduction":{"score":9,"maxScore":9,"error":0},"keyphraseInSubHeadings":{"score":3,"maxScore":9,"error":1},"keyphraseInImageAlt":{"score":3,"maxScore":9,"error":1}}},"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":[],"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":"{\"article\":{\"articleType\":\"BlogPosting\"},\"course\":{\"name\":\"\",\"description\":\"\",\"provider\":\"\"},\"faq\":{\"pages\":[]},\"product\":{\"reviews\":[]},\"recipe\":{\"ingredients\":[],\"instructions\":[],\"keywords\":[]},\"software\":{\"reviews\":[],\"operatingSystems\":[]},\"webPage\":{\"webPageType\":\"WebPage\"}}","pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":"-1","robots_max_videopreview":"-1","robots_max_imagepreview":"large","priority":null,"frequency":"default","local_seo":null,"breadcrumb_settings":null,"limit_modified_date":false,"ai":null,"created":"2022-01-07 14:11:11","updated":"2025-07-16 14:04:15","seo_analyzer_scan_date":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/www.rjl-microanalytic.de\/en\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/www.rjl-microanalytic.de\/en\/restschmutzanalyse-technische-sauberkeit-vda-19-iso-16232\/\" title=\"Restschmutzanalyse VDA-19 &amp; ISO-16232\">Restschmutzanalyse VDA-19 &amp; ISO-16232<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tPr\u00fcfnormen der Technischen Sauberkeit\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/www.rjl-microanalytic.de\/en"},{"label":"Restschmutzanalyse VDA-19 &#038; ISO-16232","link":"https:\/\/www.rjl-microanalytic.de\/en\/restschmutzanalyse-technische-sauberkeit-vda-19-iso-16232\/"},{"label":"Pr\u00fcfnormen der Technischen Sauberkeit","link":"https:\/\/www.rjl-microanalytic.de\/en\/restschmutzanalyse-technische-sauberkeit-vda-19-iso-16232\/pruefnormen-pruefvorschriften-restschmutz-technische-sauberkeit\/"}],"_links":{"self":[{"href":"https:\/\/www.rjl-microanalytic.de\/en\/wp-json\/wp\/v2\/pages\/1188","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.rjl-microanalytic.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.rjl-microanalytic.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.rjl-microanalytic.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.rjl-microanalytic.de\/en\/wp-json\/wp\/v2\/comments?post=1188"}],"version-history":[{"count":65,"href":"https:\/\/www.rjl-microanalytic.de\/en\/wp-json\/wp\/v2\/pages\/1188\/revisions"}],"predecessor-version":[{"id":15548,"href":"https:\/\/www.rjl-microanalytic.de\/en\/wp-json\/wp\/v2\/pages\/1188\/revisions\/15548"}],"up":[{"embeddable":true,"href":"https:\/\/www.rjl-microanalytic.de\/en\/wp-json\/wp\/v2\/pages\/1171"}],"wp:attachment":[{"href":"https:\/\/www.rjl-microanalytic.de\/en\/wp-json\/wp\/v2\/media?parent=1188"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}