{"id":1386,"date":"2018-07-25T22:00:00","date_gmt":"2018-07-25T20:00:00","guid":{"rendered":"https:\/\/new.rjl-microanalytic.de\/?p=1386"},"modified":"2023-06-04T15:26:03","modified_gmt":"2023-06-04T13:26:03","slug":"analyse-von-fremdpartikeln-in-pharmazeutischen-pulvern","status":"publish","type":"post","link":"https:\/\/www.rjl-microanalytic.de\/en\/analyse-von-fremdpartikeln-in-pharmazeutischen-pulvern\/","title":{"rendered":"Analysis of Foreign Particles in Pharmaceutical Powders"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"1386\" class=\"elementor elementor-1386\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-67203664 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"67203664\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-7106707\" data-id=\"7106707\" data-element_type=\"column\" data-e-type=\"column\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-08302be elementor-widget elementor-widget-text-editor\" data-id=\"08302be\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Avoiding the presence of visible foreign particles is a core requirement in the manufacturing of pharmaceutical products. Our test laboratory has developed a simple but innovative method that enables the reliable quantification of foreign particles in pharmaceutical powders.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1486ca1c elementor-widget elementor-widget-heading\" data-id=\"1486ca1c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Preparation by Dispersion in Air<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-437d72fa elementor-widget elementor-widget-text-editor\" data-id=\"437d72fa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Our preferential method of preparation for flowable powders is via the means of a dispersion tube onto a large CN membrane (\u2205 150 mm). Following this technique, it is possible to examine ca. 100 mg of powder in a single step, increasing the statistical significance of the measurement.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6731b5e0 elementor-widget elementor-widget-image\" data-id=\"6731b5e0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/dispersion-tube-for-pharma-powder.png\" title=\"dispersion-tube-for-pharma-powder\" alt=\"dispersion-tube-for-pharma-powder\" loading=\"lazy\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1418157 elementor-widget elementor-widget-heading\" data-id=\"1418157\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Preparation by Vacuum Filtration<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3f2ddf15 elementor-widget elementor-widget-text-editor\" data-id=\"3f2ddf15\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Alternatively, the primary powder can be dissolved with a suitable solvent and the residue filtered onto a medium sized CN membrane (\u2205 47 mm). This method assumes that the foreign particles are insolvable. The technique is particularly suitable for the investigation of metallic and mineral foreign particles (\"elemental impurities\").<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b4fd508 elementor-widget elementor-widget-image\" data-id=\"b4fd508\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/vacuum-filtration-pharma-powder.png\" title=\"vacuum-filtration-pharma-powder\" alt=\"vacuum-filtration-pharma-powder\" loading=\"lazy\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-00c13c6 elementor-widget elementor-widget-heading\" data-id=\"00c13c6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Analysis Method for Foreign Particles<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1abbcd5d elementor-widget elementor-widget-text-editor\" data-id=\"1abbcd5d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>We utilize an optical measuring method based on an\u00a0<a class=\"unterstrichen\" href=\"\/en\/go-to\/microquick\/\">imaging scanner,<\/a>\u00a0in order to quickly and reliably detect all visible foreign particles. The measurement result is available in two minutes:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-869a136 elementor-widget elementor-widget-image\" data-id=\"869a136\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/tabelle-fremdpartikel-pro-100mg.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"tabelle-fremdpartikel-pro-100mg\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6Mjc2NywidXJsIjoiaHR0cHM6XC9cL3d3dy5yamwtbWljcm9hbmFseXRpYy5kZVwvd3AtY29udGVudFwvdXBsb2Fkc1wvdGFiZWxsZS1mcmVtZHBhcnRpa2VsLXByby0xMDBtZy5wbmcifQ%3D%3D\">\n\t\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/tabelle-fremdpartikel-pro-100mg.png\" title=\"table-foreign-particles-per-100mg\" alt=\"tabelle-fremdpartikel-pro-100mg\" class=\"elementor-animation-float\" loading=\"lazy\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5fdbaf21 elementor-widget elementor-widget-text-editor\" data-id=\"5fdbaf21\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Alternatively, we offer the analysis of\u00a0<a class=\"unterstrichen\" href=\"\/en\/analysenservice-mit-iso-17025-akkreditierung\/sem-edx-identifikation-partikelverunreinigungen\/\">foreign particles using SEM-EDX.<\/a>\u00a0This method can detect the foreign particles while simultaneously typing the material.<\/p><p>Talk to our\u00a0<a class=\"unterstrichen\" href=\"\/en\/company\/mitarbeiter-team\/\">experts<\/a>\u00a0and benefit from our many years of experience.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>A central requirement in the production of pharmaceutical products is the avoidance of visible foreign particles. Our testing laboratory has developed innovative yet simple methods to reliably quantify foreign particles in pharmaceutical powders.<\/p>","protected":false},"author":1,"featured_media":2000,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[9,11],"tags":[69,14,70,22,24,32,68,52,38,39,41,43,44,45,49,50,51],"class_list":["post-1386","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-innovative-analytik","category-analyse-technische-sauberkeit","tag-analysen-mit-akkreditierung","tag-bauteilsauberkeit","tag-fremdpartikel","tag-iso-16232","tag-medizinprodukt","tag-partikelanalyse","tag-prueflabor","tag-reinheit","tag-restschmutz","tag-restschmutzanalyse","tag-roentgenelementanalyse","tag-sauberkeitsanalyse","tag-sauberkeitspruefung","tag-sem-edx","tag-technische-sauberkeit","tag-vda-19","tag-vdi-2083-blatt-21"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.rjl-microanalytic.de\/en\/wp-json\/wp\/v2\/posts\/1386","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.rjl-microanalytic.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.rjl-microanalytic.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.rjl-microanalytic.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.rjl-microanalytic.de\/en\/wp-json\/wp\/v2\/comments?post=1386"}],"version-history":[{"count":37,"href":"https:\/\/www.rjl-microanalytic.de\/en\/wp-json\/wp\/v2\/posts\/1386\/revisions"}],"predecessor-version":[{"id":10339,"href":"https:\/\/www.rjl-microanalytic.de\/en\/wp-json\/wp\/v2\/posts\/1386\/revisions\/10339"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.rjl-microanalytic.de\/en\/wp-json\/wp\/v2\/media\/2000"}],"wp:attachment":[{"href":"https:\/\/www.rjl-microanalytic.de\/en\/wp-json\/wp\/v2\/media?parent=1386"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.rjl-microanalytic.de\/en\/wp-json\/wp\/v2\/categories?post=1386"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.rjl-microanalytic.de\/en\/wp-json\/wp\/v2\/tags?post=1386"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}