{"id":1443,"date":"2021-08-13T22:00:00","date_gmt":"2021-08-13T20:00:00","guid":{"rendered":"https:\/\/new.rjl-microanalytic.de\/?p=1443"},"modified":"2023-06-01T14:28:41","modified_gmt":"2023-06-01T12:28:41","slug":"ebsd-analytik-zum-ersten-mal-in-einem-tabletop-sem-edx-realisiert","status":"publish","type":"post","link":"https:\/\/www.rjl-microanalytic.de\/en\/ebsd-analytik-zum-ersten-mal-in-einem-tabletop-sem-edx-realisiert\/","title":{"rendered":"EBSD Implemented for the First Time in a Tabletop SEM-EDX"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"1443\" class=\"elementor elementor-1443\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-5622b33 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"5622b33\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-dfa4b0b\" data-id=\"dfa4b0b\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-b9f857a elementor-widget elementor-widget-text-editor\" data-id=\"b9f857a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\tWe recently supported Bruker Nano in installing a compact EBSD system for the first time in the world on our <a class=\"unterstrichen\" href=\"\/en\/instrumente\/coxem-tabletop-benchtop-sem-edx-tischgeraete\/\">Coxem Tabletop SEM-EDX<\/a> Thanks to good preparation, the installation went smoothly and after an hour we were able to record the first EBSD mappings. For Bruker and Coxem, this test represents an important step towards commercializing EBSD technology for SEM-EDX desktop devices.\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e5c292e elementor-widget elementor-widget-image\" data-id=\"e5c292e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/Coxem-Tabletop-SEM-EDX-EBSD.jpg\" title=\"Coxem-Tabletop-SEM-EDX-EBSD\" alt=\"Coxem-Tabletop-SEM-EDX-EBSD\" loading=\"lazy\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-51201c1 elementor-widget elementor-widget-text-editor\" data-id=\"51201c1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Electron Backscatter Diffraction (EBSD) provides line patterns (so-called Kikuchi patterns) that reflect the crystallographic orientation of the examined sample areas. Commercially available aluminum foil was used as the test object and an area of approx. 40 \u00b5m x 80 \u00b5m was measured over a period of one hour.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dee2f96 elementor-widget elementor-widget-image\" data-id=\"dee2f96\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/Coxem-Tabletop-SEM-EDX-EBSD-IPF-Map-Aluminium-foil.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"Coxem-Tabletop-SEM-EDX-EBSD-IPF-Map-Aluminium-foil\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6MTk3OCwidXJsIjoiaHR0cHM6XC9cL3d3dy5yamwtbWljcm9hbmFseXRpYy5kZVwvd3AtY29udGVudFwvdXBsb2Fkc1wvQ294ZW0tVGFibGV0b3AtU0VNLUVEWC1FQlNELUlQRi1NYXAtQWx1bWluaXVtLWZvaWwucG5nIn0%3D\">\n\t\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www.rjl-microanalytic.de\/wp-content\/uploads\/Coxem-Tabletop-SEM-EDX-EBSD-IPF-Map-Aluminium-foil.png\" title=\"Coxem Tabletop SEM EDX EBSD IPF Map Aluminum foil\" alt=\"Coxem-Tabletop-SEM-EDX-EBSD-IPF-Map-Aluminium-foil\" class=\"elementor-animation-float\" loading=\"lazy\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8f734a5 elementor-widget elementor-widget-text-editor\" data-id=\"8f734a5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\tWe were particularly impressed by the stability of the electron beam during the entire acquisition period, which is not necessarily given for larger SEMs. We were able to collect promising results on this comparatively complicated sample, which confirm the feasibility of the EBSD applications in the compact table format.\n<ul>\n \t<li>\n<ul>\n \t<li>Semi-automatic grain size and shape distribution analysis<\/li>\n \t<li>Quantitative analysis of microstructures and sub-areas<\/li>\n \t<li>Determination of the area or volume fraction of deformed or recrystallized grains<\/li>\n \t<li>Grain boundary analysis<\/li>\n \t<li>Phase identification and phase distribution analysis<\/li>\n \t<li>Correlation of chemical and crystallographic results<\/li>\n \t<li>Orientation distribution analysis - crystallographic texture analysis<\/li>\n<\/ul>\n<\/li>\n<\/ul>\nThe already extensive\u00a0<a class=\"unterstrichen\" href=\"\/en\/instrumente\/coxem-tabletop-benchtop-sem-edx-tischgeraete\/\">Coxem SEM-EDX Portfolio<\/a>\u00a0is enriched by an exclusive segment with EBSD and now offers:\n<ul>\n \t<li>\n<ul>\n \t<li>SE \u2013 Secondary electron microscopy for imaging by topography and morphology<\/li>\n \t<li>BSE \u2013 Backscattered electron icroscopy for imaging by material contrast<\/li>\n \t<li>EDX \u2013 X-ray element spectroscopy<\/li>\n \t<li>STEM - Transmission electron microscopy<\/li>\n \t<li>ESBD - Electron backscatter diffraction for crystallographic orientation<\/li>\n \t<li>Sputter - Sample coating for conductivity<\/li>\n \t<li>Cooling Stage - Sample cooling for vacuum-unstable samples<\/li>\n \t<li>Low vacuum - Discharge of non-conductive materials<\/li>\n \t<li>Cross-Section Polisher - Surface polishing<\/li>\n<\/ul>\n<\/li>\n<\/ul>\nFor more information on the method, see\u00a0<a class=\"unterstrichen\" href=\"https:\/\/www.bruker.com\/de\/products-and-solutions\/elemental-analyzers\/eds-wds-ebsd-SEM-Micro-XRF\/quantax-ed-xs.html\">Bruker Nano<\/a>. If you are interested in your own system, we look forward to hearing from you\u00a0<a class=\"unterstrichen\" href=\"\/en\/company\/kontakt\/\">hearing from you<\/a>.\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>We supported Bruker Nano in the world's first commissioning of a compact EBSD system on our Coxem Tabletop SEM-EDX. The installation went smoothly and after one hour we were able to record the first EBSD mappings \u2012 Important step for the market introduction of the EBSD technology for SEM-EDX tabletop devices.<\/p>","protected":false},"author":1,"featured_media":1978,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[9,12],"tags":[16,17,37,45],"class_list":["post-1443","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-innovative-analytik","category-elektronenmikroskopie-sem-edx","tag-coxem","tag-ebsd","tag-rasterelektronenmikroskopie","tag-sem-edx"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.rjl-microanalytic.de\/en\/wp-json\/wp\/v2\/posts\/1443","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.rjl-microanalytic.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.rjl-microanalytic.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.rjl-microanalytic.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.rjl-microanalytic.de\/en\/wp-json\/wp\/v2\/comments?post=1443"}],"version-history":[{"count":77,"href":"https:\/\/www.rjl-microanalytic.de\/en\/wp-json\/wp\/v2\/posts\/1443\/revisions"}],"predecessor-version":[{"id":10262,"href":"https:\/\/www.rjl-microanalytic.de\/en\/wp-json\/wp\/v2\/posts\/1443\/revisions\/10262"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.rjl-microanalytic.de\/en\/wp-json\/wp\/v2\/media\/1978"}],"wp:attachment":[{"href":"https:\/\/www.rjl-microanalytic.de\/en\/wp-json\/wp\/v2\/media?parent=1443"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.rjl-microanalytic.de\/en\/wp-json\/wp\/v2\/categories?post=1443"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.rjl-microanalytic.de\/en\/wp-json\/wp\/v2\/tags?post=1443"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}